1. Home
  2. SmartAccess
  3. SmartAccess Bus
  4. Wall reader (bus) DoorLock-WA6 – MANUAL

Wall reader (bus) DoorLock-WA6 – MANUAL

DATASHEET KXC-WA6-IPx

Overview

Kentix IP wall readers enable contactless control of doors with a MIFARE® DESFire® RFID chip. All electronics are located on a compact unit. Due to its compact design, the reader is particularly suitable for use with narrow metal profiles. The setup always consists of the actual wall reader and the connected Kentix AccessManager. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.

A Kentix AccessManager for Cable Reader (KXP-2-RS) is required to operate the frame reader. Information about the relay and circuit diagrams including examples can be found here: AccessManager (Bus)

Safety instructions

Installation
Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.
No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.
Certain levels of protection must be provided when installing Kentix equipment.
Observe the relevant regulations for installations in the respective environment.
Only operate the products within the defined temperature range.
The instructions should be passed on to the user by the person carrying out the installation.
Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.
Kentix shall not be liable in the event of malfunctions, damage to property or other damage.
Use of the products, transport and storage
Protect the device during transport, storage and operation from
Protect moisture, dirt and damage.
Battery powered products
Do not use products in potentially explosive atmospheres.
Only operate the products within the defined temperature range.
Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.
Do not charge, short circuit, open or heat batteries.
When inserting the batteries, pay attention to the correct polarity.
The devices must always be operated with the batteries intended for the product.
When changing batteries, always replace all batteries.
Dispose of old or used batteries properly.
Keep batteries out of the reach of children.
Maintenance
Kentix devices must be checked for functionality as part of annual maintenance.
Disposal
Electrical appliances and batteries must be disposed of separately from household waste.

Controls

KXC-WA6-IP Front panel

WA6-IP Front view

DIP switch rear side

WA6-IP DIP switch
DIP switch Function
1Address 1(1=ON, 2=OFF)
2Address 2(1=OFF, 2=ON)
3
4
5Baud rate(ON)
6Terminating resistor
WA6-IP Table DIP switches

Terminal assignment

ClampFunction
110-30V/DC, max. 3,5VA
2GND
3RS485 Data “A
4RS485 Data
WA6-IP Terminal assignment

Wiring

WA6-IP circuitry

User and access management

The administration of users and access rights is done on the main device of the installation with KentixOne.

All information about the software is available in the KentixONE section.

Signaling

FunctionSignal and explanation
Wall reader is offlineLED flashes magenta
Access grantedshort tone, LED flashes green
Access deniedshort tone, LED flashes red
Zone is armed3 long tones, simultaneously LED flashes 3x red
Zone is armedLED flashes red regularly
Arming not possiblelong tone, LED flashes red
Table signaling

Was this article helpful?

Related Articles