DATASHEET KXC-WA6-IPx
Overview
Kentix IP wall readers enable contactless control of doors with a MIFARE® DESFire® RFID chip. All electronics are located on a compact unit. Due to its compact design, the reader is particularly suitable for use with narrow metal profiles. The setup always consists of the actual wall reader and the connected Kentix AccessManager. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.
Safety instructions
No modifications of any kind may be made to Kentix GmbH products, with the exception of those described in the relevant instructions.
When installing Kentix devices, certain degrees of protection must be guaranteed.
Observe the relevant regulations for installations in the respective environment.
Only operate the products within the defined temperature range.
The instructions should be passed on to the user by the person carrying out the installation.
Kentix accepts no liability for damage to the devices or components caused by incorrect installation. Kentix accepts no liability for incorrectly programmed units.
Kentix accepts no liability for faults, material damage or other damage.
moisture, dirt and damage during transportation, storage and operation.
Only operate the products within the defined temperature range.
Installation and battery replacement may only be carried out by trained specialist personnel in accordance with the instructions.
Do not charge, short-circuit, open or heat batteries.
Observe the correct polarity when inserting the batteries.
The devices must always be operated with the batteries intended for the product.
When changing the batteries, always replace all batteries.
Dispose of old or used batteries properly.
Keep batteries out of the reach of children.
Controls
KXC-WA6-IP Front panel

DIP switch rear side

| DIP switch | Function |
|---|---|
| 1 | Address 1(1=ON, 2=OFF) |
| 2 | Address 2(1=OFF, 2=ON) |
| 3 | – |
| 4 | – |
| 5 | Baud rate(ON) |
| 6 | Terminating resistor |
Terminal assignment
| Clamp | Function |
|---|---|
| 1 | 10-30V/DC, max. 3,5VA |
| 2 | GND |
| 3 | RS485 Data “A |
| 4 | RS485 Data |
Wiring

User and access management
The administration of users and access rights is done on the main device of the installation with KentixOne.
All information about the software is available in the KentixONE section.
Signaling
| Function | Signal and explanation |
| Wall reader is offline | LED flashes magenta |
| Access granted | short tone, LED flashes green |
| Access denied | short tone, LED flashes red |
| Zone is armed | 3 long tones, simultaneously LED flashes 3x red |
| Zone is armed | LED flashes red regularly |
| Arming not possible | long tone, LED flashes red |