DATASHEET KXC-WA6-IPx
Overview
Kentix IP wall readers enable contactless control of doors with a MIFARE® DESFire® RFID chip. All electronics are located on a compact unit. Due to its compact design, the reader is particularly suitable for use with narrow metal profiles. The setup always consists of the actual wall reader and the connected Kentix AccessManager. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.
Safety instructions
No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.
Certain levels of protection must be provided when installing Kentix equipment.
Observe the relevant regulations for installations in the respective environment.
Only operate the products within the defined temperature range.
The instructions should be passed on to the user by the person carrying out the installation.
Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.
Kentix shall not be liable in the event of malfunctions, damage to property or other damage.
Protect moisture, dirt and damage.
Only operate the products within the defined temperature range.
Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.
Do not charge, short circuit, open or heat batteries.
When inserting the batteries, pay attention to the correct polarity.
The devices must always be operated with the batteries intended for the product.
When changing batteries, always replace all batteries.
Dispose of old or used batteries properly.
Keep batteries out of the reach of children.
Controls
KXC-WA6-IP Front panel
DIP switch rear side
DIP switch | Function |
---|---|
1 | Address 1(1=ON, 2=OFF) |
2 | Address 2(1=OFF, 2=ON) |
3 | – |
4 | – |
5 | Baud rate(ON) |
6 | Terminating resistor |
Terminal assignment
Clamp | Function |
---|---|
1 | 10-30V/DC, max. 3,5VA |
2 | GND |
3 | RS485 Data “A |
4 | RS485 Data |
Wiring
User and access management
The administration of users and access rights is done on the main device of the installation with KentixOne.
All information about the software is available in the KentixONE section.
Signaling
Function | Signal and explanation |
Wall reader is offline | LED flashes magenta |
Access granted | short tone, LED flashes green |
Access denied | short tone, LED flashes red |
Zone is armed | 3 long tones, simultaneously LED flashes 3x red |
Zone is armed | LED flashes red regularly |
Arming not possible | long tone, LED flashes red |