The assembly of the Kentix SmartXcan is done in a few steps. All the necessary tools for mounting on a wall are included.


  1. The wall bracket is attached to the wall at a height of 110 cm

  2. The SmartXcan mounting bracket is attached to the wall bracket
  3. The Kentix SmartXcan is fixed on the mounting bracket
    Open: For disassembly, the tab must be pressed down with a screwdriver, pin, etc. Only then can the SmartXcan be removed upwards.
    Fix: To mount the SmartXcan on the mounting bracket, the device is placed on the appropriate tabs of the mounting bracket and fixed by pushing the SmartXcan downwards.

Stand

To place the SmartXcan in a free space the Kentix SmartXcan stand can be used.
The stand is 110 cm high. The SmartXcan mounted on it is inclined at 60°. This height and tilt allows both smaller people and larger ones to easily measure temperature and maintain the required measuring distance.

Technical drawing SmartXcan Stand   (subject to modifications!)

Mounting instruction Stand

The shaft of the stand is attached to the base plate with three 4.5 X 70mm, Pozidriv PZ2 screws.

SmartXcan Stand