The basic settings for each device include the activation status (on/off) and a name under which all alarms and warnings reported by this device are displayed. This should be as clearly descriptive as possible in order to distinguish the devices.
By selecting the higher-level alarm group, the device is assigned to the system hierarchy.
Alarms are signaled in the higher-level alarm group.
The type of device used to perform a PUE (Power Usage Effectiveness) measurement can be specified. The specific settings include the selection of the sign, the word sequence and the read function.
Phases
Individual settings can be made for each phase. The general settings include a name, the address and a billing that can bill this phase.
Alarm settings
Depending on the alarm assignment set, a monitored value can always or only trigger an alarm when armed and then sends an alarm to all users who have authorization for the device (the assignment is made via the alarm groups) and notifications for the alarm type. In principle, all alarm assignments can always trigger alarms. The only exceptions to this are “Arm-active” (alarm only if the higher-level alarm group has been armed) and “Display only” (no alarm evaluation takes place).
Warnings and alarms are always triggered if the value measured by the device exceeds (for Max.) or falls below (for Min.) one of the configured threshold values.
Name | API value | Description |
---|---|---|
From | off | The alarm is deactivated for this input and the status/measured value is not updated. |
Sharp-Active | armed-active | If the higher-level alarm group has been armed, alarms can be triggered. The status/measured value of the input is updated. |
Permanently active | always-active | Alarms can be triggered independently of the switching status of the alarm group. The status/measured value of the input is updated. |
fire | fire | Alarms can always be triggered. These are reported as fire alarms. |
Sabotage | sabotage | Alarms can always be triggered. These are reported as sabotage/intrusion alarms. |
System message | system | Alarms can always be triggered. These are reported as a system message. |
Connection settings
The connection can be configured individually for the individual measured values by selecting the Modbus register and selecting a factor and the data type. The corresponding configuration specifications can be found in the device manual.
Webhooks
Webhooks in KentixONE offer the option of sending an HTTP request to an external server when an event occurs. Each webhook can be assigned the types of alarms or warnings for which it should be sent.