User Interfaces |
|
Measuring speed of the temperature measurement | approx. 0.6 seconds after head position detection Typical measuring time per person (approach - measure - step away) approx. 5 seconds |
Software connection option | Kentix|OS, stand-alone operation with integrated web server (HTTPS) Connection via network to AlarmManager-PRO |
Sensor - Roomtemperature | Measuring range -40 bis 85°C (Accuracy ± 0,5°C) |
Sensor - Rel. Humdity | Measuring range 0 bis 100% (Accuracy ±3%) |
Sensor - Dew-Point | calculated in °C |
Sensor - IR Thermal Array | 1024 pixel infrared array, measuring range 0-100°C, repeatability ±0.3°C, resolution 0.1°C, emission factor 0.98, ideal ambient temperature for measurement 18 - 28°C |
Sensor - Distance | Distance measurement with resolution of 1mm. Class 1 eye safe laser measurement in accordance with the latest standard IEC 60825-1:2014-3 |
Sensor - Vibration | 3-axis acceleration sensor with position and sabotage detection (sensitivity adjustable), measuring range 0.25-5G |
Sensor - External input | 2 x alarm input (e.g. measurement OK/NOK) Wiring with potential-free contacts via separate KIO3 power adapter |
Buzzer | Acoustic measurement confirmation via buzzer, 85dB, 2.3kHz |
Sensor - External output | 2x signal output (e.g. measurement OK/NOK) to control doors, turnstiles etc., wiring via separate KIO3 power adapter with relay outputs |
LED indication | Temperature scale with 8x LED for temperature indication and display of four temperature ranges Illuminated ring with 4x LED for focusing and measurement display LINK/ACT to Ethernet socket |
Ethernet - LAN | 10/100MBit, PoE (Class 1, approx. 2W) for power supply |
SD card | Integrated Micro SD card holder as additional memory for image recording, up to 128 GB |
SNMP | SNMP V2/3 (get/set), SNMP Traps (Simple Network Management Protocol) |
ReST API | ReST API with JSON objetcs (HTTPS), Webhooks with free datastructure |
KENTIX system port | RJ45 for connecting external Kentix expansion modules |
Chassis | Material: PS 120 x 120 x 44 mm weight approx. 150g, protection class IP30 |
Ambient temperature for body temperature measurement | 18 - 24°C recommendation recommendation for accurate measurement 16 - 28°C extended range, lower accuracy possible |
Ambient temperature device operation | 0 - 50°C for pure device operation, observe measuring range Air humidity 5-95% non-condensing |
Types | KMS-TI-FS-B KMS-TI-FS-RFID-B (with RFID reader Mifare DESFire) |
Content of delivery | 1 pc. SmartXcan Sensor 1 pc. Cover for connections 1 pc. Metal wall bracket, device holder, fixing set 1 pc. Slim-Line patch cable 3m (CAT6) |
Accessories (not included in delivery) | PoE injector (ART: KPOE100EU) IO adapter with power supply unit for controlling external devices (KIO3) |
Approvals | CE, FCC |