SmartAccess
Wall Reader (Bus)
Applies to all DoorLock-WA2, -WA3, -WA4, -WA6, -WA9
Parent Device
Select the parent device under which the new device should be integrated.
With multiple locations or separate networks, care must be taken to ensure that communication between the two devices is possible.
All AccessManagers (Bus) are available.
Address
Communication with the device is established via the address and optionally the network port. In most cases, IPv4 and DNS addresses can be used.
Finalize
Now click on Add and wait until the message Device successfully added is displayed.
The configuration mask of the newly added device can be opened directly via the link button.
DoorLock (RF)
Applies to DoorLock (RF Zigbee) and DoorLock (RF BLE)
Parent Device
Select the parent device under which the new device should be integrated.
With multiple locations or separate networks, care must be taken to ensure that communication between the two devices is possible.
Available hosts are all AccessManagers and MultiSensor-LAN/TI-BLE in Access mode.
To ensure optimal communication, pay attention to the environment of both devices. For example, walls, floors/ceilings, or even frosted glass doors can severely limit the wireless range.
AccessManager (RF-BLE) and MultiSensors can only be used as hosts for DoorLocks with BLE communication.
Alarm Group
The alarm group determines which logical or spatial unit the new device is integrated into. This determines, for example, the alarm and notification behavior of all subordinate devices.
Name
The name serves for unique identification of the device in KentixONE.
Since device names are used in the Detail View as well as in the log books, descriptive names are recommended. Good device identifiability greatly increases the clarity of the system.
Hold the service key card in front of the DoorLock to start the pairing process.
Finalize
Now click on Add and wait until the message Device successfully added is displayed.
The configuration mask of the newly added device can be opened directly via the link button.
RackLock (BUS)
Applies to RackLock-RA4
Parent Device
Select the parent device under which the new device should be integrated.
With multiple locations or separate networks, care must be taken to ensure that communication between the two devices is possible.
All AccessManagers (Bus) are available (formerly "relay module").
Alarm Group
The alarm group determines which logical or spatial unit the new device is integrated into. This determines, for example, the alarm and notification behavior of all subordinate devices.
Enter the BUS ID (for older devices Teachincode) which can be found on a sticker on the back of the device.
Name
The name serves for unique identification of the device in KentixONE.
Since device names are used in the Detail View as well as in the log books, descriptive names are recommended. Good device identifiability greatly increases the clarity of the system.
Finalize
Now click on Add and wait until the message Device successfully added is displayed.
The configuration mask of the newly added device can be opened directly via the link button.
Virtual DoorLock (BUS)
Parent Device
Select the parent device under which the new device should be integrated.
With multiple locations or separate networks, care must be taken to ensure that communication between the two devices is possible.
Available hosts are all AccessManagers (Bus).
To open a door with a virtual DoorLock, it must have e.g. a motor lock that can be controlled via a switching output of the AccessManager.
Alarm Group
The alarm group determines which logical or spatial unit the new device is integrated into. This determines, for example, the alarm and notification behavior of all subordinate devices.
Name
The name serves for unique identification of the device in KentixONE.
Since device names are used in the Detail View as well as in the log books, descriptive names are recommended. Good device identifiability greatly increases the clarity of the system.
Finalize
Now click on Add and wait until the message Device successfully added is displayed.
The configuration mask of the newly added device can be opened directly via the link button.
IdFaceMax
Parent Device
Select the parent device under which the new device should be integrated.
With multiple locations or separate networks, care must be taken to ensure that communication between the two devices is possible.
All AccessManagers (Bus) are available.
Alarm Group
The alarm group determines which logical or spatial unit the new device is integrated into. This determines, for example, the alarm and notification behavior of all subordinate devices.
Address
Communication with the device is established via the address and optionally the network port. In most cases, IPv4 and DNS addresses can be used.
Name
The name serves for unique identification of the device in KentixONE.
Since device names are used in the Detail View as well as in the log books, descriptive names are recommended. Good device identifiability greatly increases the clarity of the system.
Configure the login details for the web interface of the idFaceMax device by setting a username and password.
Finalize
Now click on Add and wait until the message Device successfully added is displayed.
The configuration mask of the newly added device can be opened directly via the link button.