{"id":13948,"date":"2023-01-08T15:24:47","date_gmt":"2023-01-08T14:24:47","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/quelle-est-laffectation-de-la-prise-rj45-des-kentix-sytemports-type-a-b\/"},"modified":"2026-04-24T14:11:22","modified_gmt":"2026-04-24T12:11:22","slug":"quelle-est-laffectation-de-la-prise-rj45-des-kentix-sytemports-type-a-b","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/quelle-est-laffectation-de-la-prise-rj45-des-kentix-sytemports-type-a-b\/","title":{"rendered":"Quelle est l&rsquo;affectation de la prise RJ45 des Kentix Sytemports (type A\/B) ?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-1024x768.jpeg\" alt=\"\" class=\"wp-image-568\" style=\"width:512px;height:384px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-1024x768.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-1536x1152.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-100x75.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Le port syst\u00e8me Kentix (type A) du MultiSensor permet de connecter des composants syst\u00e8me tels que des capteurs de fuite, des contacts de porte, des sir\u00e8nes ou des alarmes externes d&rsquo;onduleurs ou de climatiseurs. Dans le cas du MultiSensor-RF, l&rsquo;alimentation \u00e9lectrique est \u00e9galement assur\u00e9e par le port syst\u00e8me (type A). <\/p>\n\n<p class=\"wp-block-paragraph\">Pour la connexion d&rsquo;appareils externes ou d&rsquo;alarmes avec entr\u00e9es ou sorties, il existe un module d&rsquo;extension (port syst\u00e8me) disponible s\u00e9par\u00e9ment avec ORDER_CODE : KIO3.<\/p>\n\n<h3 class=\"wp-block-heading\">Vous trouverez l&rsquo;affectation du port syst\u00e8me (type A) dans le sch\u00e9ma de c\u00e2blage suivant.<\/h3>\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"705\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort.png\" alt=\"\" class=\"wp-image-542\" style=\"width:150px;height:176px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort.png 598w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-339x400.png 339w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-127x150.png 127w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-42x50.png 42w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-51x60.png 51w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-85x100.png 85w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-1ea22f17-dd40-461b-a8b8-fc6b40201ad7\"><ol class=\"fa-ul\"><li>Tension interne du syst\u00e8me (GND) - Pas d&rsquo;utilisation <strong> externe*<\/strong>.<\/li><li>Sortie 1 (collecteur ouvert, 100mA max.)<\/li><li>Sortie 2 (collecteur ouvert, max 100mA)<\/li><li><strong>Tension d&rsquo;alimentation externe**<\/strong><\/li><li><strong>Tension d&rsquo;alimentation externe**<\/strong><\/li><li>Entr\u00e9e 1 (circuit libre de potentiel)<\/li><li>Entr\u00e9e 2 (circuit libre de potentiel)<\/li><li><strong>Tension interne du syst\u00e8me (5VDC) - Pas d&rsquo;utilisation externe*\/**<\/strong><\/li><\/ol><style>#heroic-styled-list-1ea22f17-dd40-461b-a8b8-fc6b40201ad7 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">L&rsquo;affectation du port syst\u00e8me (type B) diff\u00e8re comme suit :<\/h3>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8dcf5574-8bf3-436a-aafb-83e8f364d54c\"><ol class=\"fa-ul\"><li>Tension interne du syst\u00e8me (GND) - Pas d&rsquo;utilisation <strong> externe*<\/strong>.<\/li><li>Sortie 1 (collecteur ouvert, 100mA max.)<\/li><li>Sortie 2 (collecteur ouvert, max 100mA)<\/li><li><strong>Interface RS485 (A)<\/strong>**<\/li><li><strong>Interface RS485 (B)<\/strong>**<\/li><li>Entr\u00e9e 1 (circuit libre de potentiel)<\/li><li>Entr\u00e9e 2 (circuit libre de potentiel)<\/li><li><strong>Tension interne du syst\u00e8me (24VDC) - Pas d&rsquo;utilisation externe*\/**<\/strong><\/li><\/ol><style>#heroic-styled-list-8dcf5574-8bf3-436a-aafb-83e8f364d54c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\"><strong>* Ces connecteurs sont uniquement destin\u00e9s \u00e0 un usage interne.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><strong>** Affectation diff\u00e9rente entre le port syst\u00e8me de type A et de type B<\/strong><\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">Le c\u00e2blage ne doit \u00eatre effectu\u00e9 que par un sp\u00e9cialiste ayant des connaissances en \u00e9lectrotechnique. Un mauvais c\u00e2blage peut entra\u00eener des courts-circuits et des d\u00e9fauts.<br>Pour le c\u00e2blage externe du port syst\u00e8me Kentix (type A), nous recommandons toujours l&rsquo;utilisation d&rsquo;un module d&rsquo;extension (ORDER-CODE : KIO3). Le module d&rsquo;extension ne doit pas \u00eatre utilis\u00e9 en combinaison avec le port syst\u00e8me Kentix (type B).    <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Le port syst\u00e8me Kentix (type A) du MultiSensor permet de connecter des composants syst\u00e8me tels que des capteurs de fuite, des contacts de porte, des sir\u00e8nes ou des alarmes externes d&rsquo;onduleurs ou de climatiseurs. Dans le cas du MultiSensor-RF, l&rsquo;alimentation \u00e9lectrique est \u00e9galement assur\u00e9e par le port syst\u00e8me (type A)&#8230;.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[262],"ht-kb-tag":[],"class_list":["post-13948","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-faq-2"],"custom_fields":[],"categories":[{"slug":"faq-2","name":"FAQ","shortName":"FAQ"}],"featured_media_url":null,"_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13948","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13948"}],"version-history":[{"count":2,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13948\/revisions"}],"predecessor-version":[{"id":13986,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13948\/revisions\/13986"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13948"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13948"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13948"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}