{"id":13844,"date":"2023-03-29T11:24:21","date_gmt":"2023-03-29T09:24:21","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/lecteur-mural-bus-doorlock-wa4-v2-manuel-dutilisation\/"},"modified":"2026-04-24T14:07:22","modified_gmt":"2026-04-24T12:07:22","slug":"lecteur-mural-bus-doorlock-wa4-v2-manuel-dutilisation","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/lecteur-mural-bus-doorlock-wa4-v2-manuel-dutilisation\/","title":{"rendered":"Lecteur mural (bus) DoorLock-WA4-V2 - MANUEL D&rsquo;UTILISATION"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/https:\/\/docs.kentix.com\/de\/knowledge-base\/doorlock-kxc-wa3-outdoor-v2-datenblatt\/\" target=\"_blank\" rel=\"noreferrer noopener\">FICHE TECHNIQUE KXC-WA4-IPx-V2<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Aper\u00e7u<\/h2>\n\n<p class=\"wp-block-paragraph\">Les lecteurs muraux IP de Kentix permettent de commander des portes sans contact avec une puce RFID MIFARE\u00ae DESFire\u00ae. Le lecteur mural d&rsquo;ext\u00e9rieur est con\u00e7u pour \u00eatre install\u00e9 \u00e0 l&rsquo;ext\u00e9rieur. L&rsquo;\u00e9lectronique du lecteur est log\u00e9e dans un bo\u00eetier \u00e9tanche \u00e0 la poussi\u00e8re et prot\u00e9g\u00e9 contre les jets d&rsquo;eau et r\u00e9pond \u00e0 l&rsquo;indice de protection IP66. La structure se compose toujours du lecteur mural proprement dit et du Kentix <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager<\/a> connect\u00e9. Le lecteur mural est raccord\u00e9 \u00e0 l&rsquo;AccessManager par une connexion \u00e0 4 fils. L&rsquo;AccessManager lui-m\u00eame est directement connect\u00e9 \u00e0 un commutateur r\u00e9seau compatible Power over Ethernet (PoE). Pour commander les g\u00e2ches \u00e9lectriques\/serrures motoris\u00e9es, le SmartRelay offre deux sorties de relais et, selon la classe de puissance de la g\u00e2che, un r\u00e9partiteur PoE int\u00e9gr\u00e9 avec sortie 24 VDC.      <\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Pour le fonctionnement des lecteurs muraux (version : V2), un Kentix AccessManager pour lecteur de c\u00e2ble (KXP-2-RS) avec une version du logiciel KentixONE de 8.2.0 ou plus est n\u00e9cessaire. Vous trouverez des informations sur le relais et<strong> des sch\u00e9mas de c\u00e2blage, y compris des exemples,<\/strong> ici : &nbsp;<a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager (bus)<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Consignes de s\u00e9curit\u00e9<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">L&rsquo;installation et la mise en service ne doivent \u00eatre effectu\u00e9es que par un personnel sp\u00e9cialis\u00e9 et form\u00e9, conform\u00e9ment au mode d&#8217;emploi.<br>Aucune modification de quelque nature que ce soit, \u00e0 l&rsquo;exception de celles d\u00e9crites dans un mode d&#8217;emploi correspondant, n&rsquo;est autoris\u00e9e sur les produits de Kentix GmbH.<br>Lors de l&rsquo;installation d&rsquo;appareils Kentix, certains degr\u00e9s de protection doivent \u00eatre garantis.<br>Respectez \u00e0 cet effet les prescriptions en vigueur pour les installations dans l&rsquo;environnement concern\u00e9.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>Les instructions doivent \u00eatre transmises \u00e0 l&rsquo;utilisateur par la personne qui proc\u00e8de \u00e0 l&rsquo;installation.<br>Kentix d\u00e9cline toute responsabilit\u00e9 en cas d&rsquo;endommagement des appareils ou des composants suite \u00e0 un montage incorrect. Aucune responsabilit\u00e9 n&rsquo;est assum\u00e9e en cas d&rsquo;unit\u00e9s mal programm\u00e9es.<br>Si des dysfonctionnements, des dommages mat\u00e9riels ou autres surviennent, Kentix n&rsquo;est pas responsable. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Utilisation des produits, transport et stockage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Prot\u00e9ger l&rsquo;appareil contre l&rsquo;humidit\u00e9, la salet\u00e9 et les dommages pendant le transport, le stockage et l&rsquo;utilisation<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Produits aliment\u00e9s par batterie<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">N&rsquo;utilisez pas les produits dans des zones \u00e0 risque d&rsquo;explosion.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>L&rsquo;installation ainsi que le remplacement des piles ne doivent \u00eatre effectu\u00e9s que par un personnel qualifi\u00e9 et form\u00e9, conform\u00e9ment aux instructions.<br>Ne chargez pas, ne court-circuitez pas, n&rsquo;ouvrez pas et ne chauffez pas les piles.<br>Lors de la mise en place des piles, veillez \u00e0 respecter la polarit\u00e9.<br>Les appareils doivent toujours \u00eatre aliment\u00e9s par les piles pr\u00e9vues pour le produit.<br>Lors du remplacement des piles, remplacez toujours toutes les piles.<br>\u00c9liminez les piles usag\u00e9es ou us\u00e9es de mani\u00e8re appropri\u00e9e.<br>Conservez les piles hors de port\u00e9e des enfants.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Le fonctionnement des appareils Kentix doit \u00eatre contr\u00f4l\u00e9 dans le cadre d&rsquo;une maintenance annuelle.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>\u00c9limination des d\u00e9chets<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Les appareils \u00e9lectriques et les piles doivent \u00eatre \u00e9limin\u00e9s s\u00e9par\u00e9ment des d\u00e9chets m\u00e9nagers.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">\u00c9l\u00e9ments de commande<\/h2>\n\n<h3 class=\"wp-block-heading\">Fa\u00e7ade du bo\u00eetier<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135.png\" alt=\"\" class=\"wp-image-2459\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h3 class=\"wp-block-heading\">Connexions<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-975x1024.png\" alt=\"\" class=\"wp-image-3102\" style=\"width:488px;height:512px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-975x1024.png 975w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-381x400.png 381w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-143x150.png 143w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-768x807.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-48x50.png 48w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-57x60.png 57w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal-95x100.png 95w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-Terminal.png 1036w\" sizes=\"auto, (max-width: 975px) 100vw, 975px\" \/><figcaption class=\"wp-element-caption\">KXC-WA2-IPx-V2, face arri\u00e8re avec bornier de connexion<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Borne de raccordement<\/h3>\n\n<p class=\"wp-block-paragraph\">Le c\u00e2ble de t\u00e9l\u00e9communication de type : I-J(ST)Y 2x2x0.<sup>8mm2<\/sup> est appropri\u00e9 pour la connexion.<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Borne #<br\/>Lecteur<\/th><th>Fonction<br\/>Lecteur<\/th><th class=\"has-text-align-center\" data-align=\"center\">Borne #<br\/>AccessManager<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td>RS-485 A<\/td><td class=\"has-text-align-center\" data-align=\"center\">6 (BUS A)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><td>RS-485 B<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 (BUS B)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><td>12-30VDC (+)<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 (+)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><td>GND (-)<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 (-)<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA2-IPx-V2 Borne de connexion<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Commutateur DIP<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">DIP #<\/th><th>Fonction<\/th><th class=\"has-text-align-center\" data-align=\"center\">Param\u00e8tres par d\u00e9faut<br\/><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><td>RS485 BIAS ON\/OFF<\/td><td class=\"has-text-align-center\" data-align=\"center\">OFF<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><td>-<\/td><td class=\"has-text-align-center\" data-align=\"center\">-<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><td>Terminaison 120 ohms<br\/>(r\u00e9sistance de terminaison)<\/td><td class=\"has-text-align-center\" data-align=\"center\">OFF<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA2-IPx-V2 Commutateur DIP<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\"><strong>Important !  <\/strong>Les lecteurs muraux de diff\u00e9rentes versions (V1, V2 ) ne peuvent pas \u00eatre utilis\u00e9s sur un AccessManager. L&rsquo;identifiant de la version (par exemple V2) est cod\u00e9 dans le num\u00e9ro d&rsquo;article. <br><strong>Pour utiliser les lecteurs muraux avec la version 2 (V2), le AccessManager connect\u00e9 doit avoir au moins la version 8.2.0 de KentixONE.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">Exemple de connexion<\/p>\n\n<h3 class=\"wp-block-heading\">Un ou deux lecteurs muraux avec contacts de porte et g\u00e2ches \u00e9lectriques externes<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"640\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik.png\" alt=\"\" class=\"wp-image-5607\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik.png 853w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/grafik-100x75.png 100w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Le terminal 2 sur AccessManager fournit la communication via le bus de donn\u00e9es et l&rsquo;alimentation en tension de service pour les lecteurs muraux. (bornes 3-6). La borne 2 sert de potentiel commun pour l&rsquo;alimentation \u00e9lectrique des ouvre-portes avec la tension d&rsquo;alimentation PoE de l&rsquo;AccessManager.  <\/p>\n\n<p class=\"wp-block-paragraph\">Le terminal 1 est utilis\u00e9 pour connecter des contacts libres de potentiel (\u00ab\u00a0contacts de porte\u00a0\u00bb, bornes 1-4) et pour commuter des ouvre-portes par le biais du relais 2 (5-6) et du relais 1 (7-8). Les relais 1 et 2 commutent la borne 1 du terminal 2 au potentiel commun (terminal2, borne 2). <\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Mise en service de deux lecteurs muraux sur un AccessManager<\/strong><br>Si deux lecteurs muraux doivent \u00eatre utilis\u00e9s avec un AccessManager, proc\u00e9dez comme suit pour la mise en service :<br>Connectez le premier lecteur mural \u00e0 l&rsquo;AccessManager. Ajoutez-le dans l&rsquo;unit\u00e9 principale avec \u00ab\u00a0DoorLock (IP)\u00a0\u00bb. Une fois que le premier WallReader a \u00e9t\u00e9 ajout\u00e9 avec succ\u00e8s, d\u00e9connectez-le temporairement de l&rsquo;AccessManager pour pouvoir connecter le second WallReader et l&rsquo;ajouter \u00e9galement. Une fois que les deux appareils ont \u00e9t\u00e9 enregistr\u00e9s avec succ\u00e8s, reconnectez le premier WallReader \u00e0 l&rsquo;AccessManager, puis utilisez les deux appareils ensemble.   <\/p>\n\n<h2 class=\"wp-block-heading\">Gestion des utilisateurs et des acc\u00e8s<\/h2>\n\n<p class=\"wp-block-paragraph\">La gestion des utilisateurs et des droits d&rsquo;acc\u00e8s se fait sur l&rsquo;unit\u00e9 principale de l&rsquo;installation avec KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">Vous trouverez toutes les informations sur le logiciel dans la section <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a>.<\/p>\n\n<h2 class=\"wp-block-heading\">Signalisation<\/h2>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Fonction<\/strong><\/td><td><strong>Signal et explication<\/strong><\/td><\/tr><tr><td>Le lecteur mural est hors ligne<\/td><td>La LED clignote en magenta<\/td><\/tr><tr><td>Acc\u00e8s accord\u00e9<\/td><td>son bref, LED verte clignotante<\/td><\/tr><tr><td>La porte est ouverte gr\u00e2ce aux profils temporels<\/td><td>LED verte allum\u00e9e en permanence<\/td><\/tr><tr><td>Acc\u00e8s refus\u00e9<\/td><td>son bref, LED rouge clignotante<\/td><\/tr><tr><td>Zone en cours d&rsquo;armement<\/td><td>3 bips longs, simultan\u00e9ment la LED clignote 3 fois en rouge<\/td><\/tr><tr><td>Impossible de s&rsquo;armer<\/td><td>son long, LED rouge clignotante<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Tableau Signalisation<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>FICHE TECHNIQUE KXC-WA4-IPx-V2 Aper\u00e7u Les lecteurs muraux IP de Kentix permettent de commander des portes sans contact avec une puce RFID MIFARE\u00ae DESFire\u00ae. Le lecteur mural d&rsquo;ext\u00e9rieur est con\u00e7u pour \u00eatre install\u00e9 \u00e0 l&rsquo;ext\u00e9rieur. L&rsquo;\u00e9lectronique du lecteur est log\u00e9e dans un bo\u00eetier \u00e9tanche \u00e0 la poussi\u00e8re et prot\u00e9g\u00e9 contre les&#8230;<\/p>\n","protected":false},"author":4,"featured_media":13845,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[264],"ht-kb-tag":[],"class_list":["post-13844","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-filaire"],"custom_fields":{"kentix_order_code":["KXC-WA4-IP1-V2, KXC-WA4-IP2-V2"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartaccess-bus-filaire","name":"SmartAccess (BUS) filaire","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-OUTDOOR-IP2-front-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13844"}],"version-history":[{"count":1,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13844\/revisions"}],"predecessor-version":[{"id":13848,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13844\/revisions\/13848"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media\/13845"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13844"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13844"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}