{"id":13392,"date":"2023-03-07T10:19:54","date_gmt":"2023-03-07T09:19:54","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/smartpdu-2u-manuel-dutilisation\/"},"modified":"2026-04-24T14:05:16","modified_gmt":"2026-04-24T12:05:16","slug":"smartpdu-2u-manuel-dutilisation","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/smartpdu-2u-manuel-dutilisation\/","title":{"rendered":"SmartPDU-2U - MANUEL D&rsquo;UTILISATION"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/fr\/knowledge-base\/dual-smartpdu-2u-2x10-16a-jusqua-2x-3-6kva-fiche-technique\/\">FICHE TECHNIQUE SmartPDU-2U<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">KentixONE Mode de fonctionnement<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">SiteManager Op\u00e9ration<\/th><th class=\"has-text-align-center\" data-align=\"center\">Fonctionnement autonome<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/betriebsarten\/\">Plus d&rsquo;informations sur le mode de fonctionnement<\/a><\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Aper\u00e7u<\/h2>\n\n<p class=\"wp-block-paragraph\">La SmartPDU est optimis\u00e9e pour alimenter des terminaux dans des armoires de donn\u00e9es et de r\u00e9seau tout en surveillant l&rsquo;alimentation, en collectant des donn\u00e9es de consommation et en contr\u00f4lant l&rsquo;environnement. Elle est g\u00e9n\u00e9ralement mont\u00e9e dans un rack de 19 pouces. Avec le PowerManager et le MultiSensor int\u00e9gr\u00e9s, il est possible de g\u00e9rer facilement jusqu&rsquo;\u00e0 100 SmartPDU. Le PowerManager int\u00e9gr\u00e9 est compatible avec le r\u00e9seau et est aliment\u00e9 par Power over Ethernet (PoE).  <br\/><br\/>Le SmartPDU peut \u00eatre utilis\u00e9 comme appareil principal (mode de fonctionnement : Main Device) ou en r\u00e9seau (mode de fonctionnement : Satellite Device) avec d&rsquo;autres SmartPDU et d&rsquo;autres appareils Kentix. Le logiciel KentixONE est d\u00e9j\u00e0 int\u00e9gr\u00e9 via le serveur web int\u00e9gr\u00e9 (HTTPS). La configuration s&rsquo;effectue via un navigateur Web et, selon le mode de fonctionnement, localement sur le SmartPDU lui-m\u00eame (mode de fonctionnement : Main Device) ou sur une instance centrale comme le SiteManager ou le PowerManager (mode de fonctionnement : Satellite Device).  <\/p>\n\n<p class=\"wp-block-paragraph\">Gr\u00e2ce \u00e0 sa petite taille de seulement 9 cm (deux unit\u00e9s de hauteur), la SmartPDU-2U est id\u00e9ale pour les petites armoires de serveurs. Malgr\u00e9 sa petite taille, la SmartPDU fournit une puissance de sortie allant jusqu&rsquo;\u00e0 4,6 kVA, r\u00e9partie sur 16 prises d&rsquo;\u00e9quipement C13 (IEC 60320-1). La SmartPDU-2U est \u00e9galement disponible en version biphas\u00e9e, de sorte que les terminaux \u00e9lectroniques sont prot\u00e9g\u00e9s contre d&rsquo;\u00e9ventuelles pannes par deux alimentations s\u00e9par\u00e9es. L&rsquo;alimentation de la SmartPDU biphas\u00e9e s&rsquo;effectue \u00e0 l&rsquo;arri\u00e8re via deux prises pour appareils froids C20 (IEC 60320-1). L&rsquo;alimentation du SmartPDU monophas\u00e9 se fait \u00e0 l&rsquo;arri\u00e8re par une prise d&rsquo;appareil froid C20 (IEC 60320-1).    <\/p>\n\n<h2 class=\"wp-block-heading\">Consignes de s\u00e9curit\u00e9<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">L&rsquo;installation et la mise en service ne doivent \u00eatre effectu\u00e9es que par un personnel sp\u00e9cialis\u00e9 et form\u00e9, conform\u00e9ment au mode d&#8217;emploi.<br>Aucune modification de quelque nature que ce soit, \u00e0 l&rsquo;exception de celles d\u00e9crites dans un mode d&#8217;emploi correspondant, n&rsquo;est autoris\u00e9e sur les produits de Kentix GmbH.<br>Lors de l&rsquo;installation d&rsquo;appareils Kentix, certains degr\u00e9s de protection doivent \u00eatre garantis.<br>Respectez \u00e0 cet effet les prescriptions en vigueur pour les installations dans l&rsquo;environnement concern\u00e9.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>Les instructions doivent \u00eatre transmises \u00e0 l&rsquo;utilisateur par la personne qui proc\u00e8de \u00e0 l&rsquo;installation.<br>Kentix d\u00e9cline toute responsabilit\u00e9 en cas d&rsquo;endommagement des appareils ou des composants suite \u00e0 un montage incorrect. Aucune responsabilit\u00e9 n&rsquo;est assum\u00e9e en cas d&rsquo;unit\u00e9s mal programm\u00e9es.<br>Si des dysfonctionnements, des dommages mat\u00e9riels ou autres surviennent, Kentix n&rsquo;est pas responsable. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Utilisation des produits, transport et stockage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Prot\u00e9ger l&rsquo;appareil contre l&rsquo;humidit\u00e9, la salet\u00e9 et les dommages pendant le transport, le stockage et l&rsquo;utilisation<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Produits aliment\u00e9s par batterie<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">N&rsquo;utilisez pas les produits dans des zones \u00e0 risque d&rsquo;explosion.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>L&rsquo;installation ainsi que le remplacement des piles ne doivent \u00eatre effectu\u00e9s que par un personnel qualifi\u00e9 et form\u00e9, conform\u00e9ment aux instructions.<br>Ne chargez pas, ne court-circuitez pas, n&rsquo;ouvrez pas et ne chauffez pas les piles.<br>Lors de la mise en place des piles, veillez \u00e0 respecter la polarit\u00e9.<br>Les appareils doivent toujours \u00eatre aliment\u00e9s par les piles pr\u00e9vues pour le produit.<br>Lors du remplacement des piles, remplacez toujours toutes les piles.<br>\u00c9liminez les piles usag\u00e9es ou us\u00e9es de mani\u00e8re appropri\u00e9e.<br>Conservez les piles hors de port\u00e9e des enfants.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Le fonctionnement des appareils Kentix doit \u00eatre contr\u00f4l\u00e9 dans le cadre d&rsquo;une maintenance annuelle.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>\u00c9limination des d\u00e9chets<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Les appareils \u00e9lectriques et les piles doivent \u00eatre \u00e9limin\u00e9s s\u00e9par\u00e9ment des d\u00e9chets m\u00e9nagers.<br><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">\u00c9l\u00e9ments de commande<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Face avant<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001.png\" alt=\"\" class=\"wp-image-7747\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-2U_ports.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-6dbee31d-2dfe-49af-a5d8-fb11c653c813\"><ol class=\"fa-ul\"><li>LED d&rsquo;\u00e9tat :<br><strong>VERT :<\/strong> POWER OK, pas d&rsquo;alarmes en cours<br> ROUGE<strong>:<\/strong> POWER OK, alarmes en cours<\/li><li>Bouton de r\u00e9initialisation<\/li><li>Port Ethernet avec Power over Ethernet (100MBit, PoE classe 3)<\/li><li>Port syst\u00e8me Kentix (type B)<\/li><\/ol><style>#heroic-styled-list-6dbee31d-2dfe-49af-a5d8-fb11c653c813 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Vue lat\u00e9rale<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"826\" height=\"967\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22.png\" alt=\"\" class=\"wp-image-2715\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22.png 826w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22-342x400.png 342w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22-128x150.png 128w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22-768x899.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22-43x50.png 43w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22-51x60.png 51w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-22-85x100.png 85w\" sizes=\"auto, (max-width: 826px) 100vw, 826px\" \/><figcaption class=\"wp-element-caption\">Carte SD SmartPDU-2HE<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-289b00cd-93bd-47ed-bc13-57220a592602\"><ol class=\"fa-ul\"><li>Fente pour carte MicroSD<\/li><\/ol><style>#heroic-styled-list-289b00cd-93bd-47ed-bc13-57220a592602 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">La carte SD est n\u00e9cessaire pour effectuer une mise \u00e0 jour en masse ou pour stocker des sauvegardes automatiques.<\/p>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">La carte MicroSD doit \u00eatre ins\u00e9r\u00e9e dans le PDU lorsqu&rsquo;elle est d\u00e9mont\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Verso<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001.png\" alt=\"\" class=\"wp-image-8325\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-2U_back.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-042fc198-f9e1-476d-b678-5266e08fa51a\"><ol class=\"fa-ul\"><li>Num\u00e9ro de s\u00e9rie<\/li><li>Alimentation via deux prises C20 (IEC 60320-1) pour appareils froids (version biphas\u00e9e)<\/li><\/ol><style>#heroic-styled-list-042fc198-f9e1-476d-b678-5266e08fa51a li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">SmartPDU-2U Variantes<\/h2>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Types<\/strong><\/td><td><strong>KPMDU-RC-1600C13C19-2-16-H<\/strong><\/td><td><strong>KPMDU-NC-1600C13C19-1-16-H<\/strong><\/td><\/tr><tr><td><strong>Puissance nominale, tension<\/strong><\/td><td>2x 2.3kVA, 230V<\/td><td>1x 2.3kVA, 230V<\/td><\/tr><tr><td><strong>Fiche de connexion<\/strong><\/td><td>2x C20 prise d&rsquo;appareil froid (16A)<\/td><td>1x C20 prise d&rsquo;appareil froid (16A)<\/td><\/tr><tr><td><strong>Mesure du courant diff\u00e9rentiel<\/strong><\/td><td>mesure de courant diff\u00e9rentiel sensible AC\/DC int\u00e9gr\u00e9e<\/td><td>\/<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Fonctionnalit\u00e9s<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Protection des c\u00e2bles<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Chaque SmartPDU est exclusivement \u00e9quip\u00e9 de prises IEC-Lock. Cela permet d&rsquo;\u00e9viter le d\u00e9branchement accidentel des c\u00e2bles de connexion du c\u00f4t\u00e9 du PDU. L&rsquo;utilisation de c\u00e2bles de connexion IEC-Lock appropri\u00e9s emp\u00eache le d\u00e9branchement accidentel des c\u00e2bles de connexion au niveau de l&rsquo;\u00e9quipement terminal. Les c\u00e2bles de connexion sont disponibles en noir et en rouge.   <\/p>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-bottom is-layout-flex wp-container-core-columns-is-layout-f56f613f wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"184\" height=\"184\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11.png\" alt=\"\" class=\"wp-image-2670\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11.png 184w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-150x150.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-50x50.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-60x60.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-100x100.png 100w\" sizes=\"auto, (max-width: 184px) 100vw, 184px\" \/><figcaption class=\"wp-element-caption\">KPMDU-IL-C13C14-2\/3-B (Schwarz)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"224\" height=\"184\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6.png\" alt=\"\" class=\"wp-image-2675\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6.png 224w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-150x123.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-50x41.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-60x49.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-100x82.png 100w\" sizes=\"auto, (max-width: 224px) 100vw, 224px\" \/><figcaption class=\"wp-element-caption\">KPMDU-IL-C13C14-2\/3-R (Rouge)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"215\" height=\"214\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49.png\" alt=\"\" class=\"wp-image-2682\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49.png 215w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-150x150.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-50x50.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-60x60.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-100x100.png 100w\" sizes=\"auto, (max-width: 215px) 100vw, 215px\" \/><figcaption class=\"wp-element-caption\"><strong>KPMDU-IL-C19C20-2\/3-B <\/strong>(Schwarz)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"317\" height=\"294\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18.png\" alt=\"\" class=\"wp-image-2680\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18.png 317w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-150x139.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-50x46.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-60x56.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-100x93.png 100w\" sizes=\"auto, (max-width: 317px) 100vw, 317px\" \/><figcaption class=\"wp-element-caption\"><strong>KPMDU-IL-C19C20-2\/3-R <\/strong>(Rouge)<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Mesure du courant diff\u00e9rentiel int\u00e9gr\u00e9e (RCM) : contr\u00f4le selon DGUV V3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le SmartPDU-2U biphas\u00e9 int\u00e8gre un dispositif de mesure du courant diff\u00e9rentiel (RCM). Cela permet d&rsquo;effectuer le contr\u00f4le des installations selon la norme DGUV V3. Gr\u00e2ce \u00e0 cette mesure du courant diff\u00e9rentiel, les alimentations \u00e9lectriques d\u00e9fectueuses (alimentations pour serveurs) peuvent \u00eatre d\u00e9tect\u00e9es \u00e0 un stade pr\u00e9coce.  <\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Disjoncteur de protection de ligne<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le SmartPDU est \u00e9quip\u00e9 de disjoncteurs de 10A par segment. Les deux disjoncteurs ont une caract\u00e9ristique de d\u00e9clenchement de type C pour un courant d&rsquo;appel accru. Cela garantit qu&rsquo;en cas de panne de courant suivie d&rsquo;un retour de la tension, les fusibles ne se d\u00e9clenchent pas imm\u00e9diatement en raison du courant d&rsquo;appel lors du d\u00e9marrage simultan\u00e9 des terminaux connect\u00e9s. Le courant d&rsquo;appel peut donc \u00eatre bri\u00e8vement 5 fois sup\u00e9rieur au courant nominal. Des d\u00e9tails sur l&rsquo;\u00e9volution du courant peuvent \u00eatre trouv\u00e9s dans le diagramme suivant.    <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>I1= Courant fixe de non-d\u00e9clenchement \u00e0 30\u00b0C<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>I2= Courant de d\u00e9clenchement fixe \u00e0 30\u00b0C<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"601\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-601x1024.png\" alt=\"\" class=\"wp-image-2726\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-601x1024.png 601w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-235x400.png 235w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-88x150.png 88w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-768x1309.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-29x50.png 29w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-901x1536.png 901w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-35x60.png 35w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-59x100.png 59w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26.png 934w\" sizes=\"auto, (max-width: 601px) 100vw, 601px\" \/><figcaption class=\"wp-element-caption\">Courbe caract\u00e9ristique des fusibles avec caract\u00e9ristique C<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Param\u00e8tres d&rsquo;usine<\/h2>\n\n<p class=\"wp-block-paragraph\">Pour la configuration initiale, utilisez l&rsquo;adresse IP imprim\u00e9e sur l&rsquo;appareil ou l&rsquo;adresse attribu\u00e9e par DHCP dans un navigateur web (HTTPS). Veuillez tenir compte des param\u00e8tres r\u00e9seau de votre PC connect\u00e9. <\/p>\n\n<p class=\"wp-block-paragraph\">Aper\u00e7u des adresses IP d&rsquo;usine :<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-white-background-color has-background\"><tbody><tr><td><strong>SiteManager et AlarmManager<\/strong><\/td><td>192.168.100.222<\/td><\/tr><tr><td><strong>MultiSensor<\/strong><\/td><td>192.168.100.223<\/td><\/tr><tr><td><strong>AccessManager<\/strong><\/td><td>192.168.100.224<\/td><\/tr><tr><td><strong>PowerManager<\/strong><\/td><td>192.168.100.225<\/td><\/tr><tr><td><strong>SmartPDU<\/strong><\/td><td>192.168.100.226<\/td><\/tr><tr><td><strong>Capteur de fuite<\/strong><\/td><td>192.168.100.227<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Adresses IP d&rsquo;usine, masque de sous-r\u00e9seau : 255.255.255.0<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">Pour les appareils avec une version de firmware inf\u00e9rieure \u00e0 8.x.x, les donn\u00e9es de connexion pour le compte administrateur par d\u00e9faut sont : admin \/ password<\/p>\n\n<h2 class=\"wp-block-heading\">R\u00e9initialiser les param\u00e8tres d&rsquo;usine<\/h2>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3\"><ol class=\"fa-ul\"><li>Red\u00e9marrer l&rsquo;appareil (d\u00e9connecter et reconnecter l&rsquo;alimentation)<\/li><li>Le voyant d&rsquo;\u00e9tat s&rsquo;allume bri\u00e8vement et s&rsquo;\u00e9teint.<\/li><li>D\u00e8s que la LED d&rsquo;\u00e9tat s&rsquo;allume en vert fixe, maintenez le bouton de r\u00e9initialisation enfonc\u00e9 pendant 15 secondes jusqu&rsquo;\u00e0 ce que l&rsquo;appareil \u00e9mette un signal sonore de confirmation.<\/li><li>L&rsquo;appareil charge les param\u00e8tres d&rsquo;usine et effectue un red\u00e9marrage.<\/li><li>Apr\u00e8s environ 2 minutes, l&rsquo;appareil est accessible avec les param\u00e8tres d&rsquo;usine.<\/li><\/ol><style>#heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Tous les param\u00e8tres et donn\u00e9es existants seront irr\u00e9m\u00e9diablement supprim\u00e9s !<\/strong><br><strong>Nous vous recommandons de sauvegarder r\u00e9guli\u00e8rement votre syst\u00e8me<\/strong>.<\/p>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Instructions de montage<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15.png\" alt=\"\" class=\"wp-image-2694\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15.png 800w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-15-100x75.png 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">SmartPDU-2U Exemple d&rsquo;application<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La SmartPDU-2U s&rsquo;installe horizontalement dans un rack de 19 pouces. Pour son installation, la SmartPDU n\u00e9cessite deux unit\u00e9s de hauteur. Pour la fixation, 4 \u00e9crous \u00e0 cage et les vis correspondantes sont utilis\u00e9s. Ceux-ci ne sont pas inclus dans la livraison.   <\/p>\n<\/div>\n\n<h2 class=\"wp-block-heading\">\u00c9talonnage de la mesure de la temp\u00e9rature ambiante<\/h2>\n\n<p class=\"wp-block-paragraph\">Les MultiSENSORS de Kentix enregistrent toutes les valeurs environnementales importantes d&rsquo;une pi\u00e8ce, entre autres la temp\u00e9rature ambiante. Afin d&rsquo;obtenir une temp\u00e9rature aussi pr\u00e9cise que possible et un d\u00e9clenchement d&rsquo;alarme en cas de d\u00e9passement de la valeur limite de la temp\u00e9rature ambiante, il est recommand\u00e9 de calibrer la mesure de la temp\u00e9rature \u00e0 l&rsquo;endroit d\u00e9finitif de l&rsquo;installation. Cela est particuli\u00e8rement n\u00e9cessaire pour les capteurs avec connexion Ethernet (PoE), car une certaine chaleur propre fausse la mesure. Pour les multicapteurs aliment\u00e9s par radio et par batterie, l&rsquo;influence de la chaleur intrins\u00e8que n&rsquo;existe pas.   <\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Les MultiSensors de Kentix ne sont pas des appareils de mesure \u00e9talonn\u00e9s, mais des appareils d&rsquo;alarme dont la pr\u00e9cision de mesure est amplement suffisante pour signaler et documenter de mani\u00e8re fiable les d\u00e9passements de valeurs limites.<\/p>\n\n<p class=\"wp-block-paragraph\">Pour obtenir n\u00e9anmoins un bon r\u00e9sultat de mesure avec des valeurs de mesure compr\u00e9hensibles en cas d&rsquo;alarme, le MultiSensor doit \u00eatre calibr\u00e9 apr\u00e8s l&rsquo;installation en fonction de l&rsquo;endroit o\u00f9 il est install\u00e9. Pour ce faire, la temp\u00e9rature doit \u00eatre mesur\u00e9e de mani\u00e8re comparative \u00e0 proximit\u00e9 imm\u00e9diate (\u00e0 une distance d&rsquo;environ 5 \u00e0 10 cm) du MultiSensor \u00e0 l&rsquo;aide d&rsquo;un thermom\u00e8tre ambiant aussi pr\u00e9cis que possible. En cas de diff\u00e9rence de temp\u00e9rature entre le MultiSensor et le thermom\u00e8tre, la valeur de temp\u00e9rature peut \u00eatre corrig\u00e9e. Pour ce faire, la diff\u00e9rence de temp\u00e9rature d\u00e9termin\u00e9e entre le MultiSensor et le thermom\u00e8tre ambiant est introduite dans le logiciel KentixONE en tant que d\u00e9calage de correction. La correction a en outre une influence directe sur la mesure de l&rsquo;humidit\u00e9 relative de l&rsquo;air ainsi que sur le calcul du point de ros\u00e9e du MultiSensor.    <\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u00c9tape<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Installer le MultiSensor \u00e0 destination.<\/td><td>La position et l&rsquo;orientation du capteur ne doivent plus \u00eatre modifi\u00e9es par la suite.<br\/>Tenez compte des points suivants :<br\/>- Montez le capteur avec l&rsquo;ouverture d&rsquo;air en X vers le bas<br\/>- Ne le montez pas dans un flux d&rsquo;air<br\/>- Les ouvertures d&rsquo;a\u00e9ration du capteur doivent \u00eatre libres.<\/td><\/tr><tr><td>Effectuer la configuration du MultiSensor avec Kentix ONE.<\/td><td><\/td><\/tr><tr><td>Au plus t\u00f4t 30 minutes apr\u00e8s la mise en service<br\/>, ajustez la temp\u00e9rature du MultiSensor avec la temp\u00e9rature ambiante.<\/td><td>Pour ce faire, mesurez la temp\u00e9rature \u00e0 l&rsquo;aide d&rsquo;un thermom\u00e8tre de r\u00e9f\u00e9rence externe plac\u00e9 \u00e0 proximit\u00e9 imm\u00e9diate, \u00e0 environ 5-10 cm du MultiSensor. Il convient de noter que ce thermom\u00e8tre s&rsquo;acclimate \u00e9galement \u00e0 la pi\u00e8ce et n&rsquo;indique la temp\u00e9rature ambiante correcte qu&rsquo;apr\u00e8s quelques minutes. <\/td><\/tr><tr><td>Si une diff\u00e9rence est constat\u00e9e entre le MultiSensor et le thermom\u00e8tre, celle-ci peut \u00eatre saisie dans le champ \u00ab\u00a0Offset\u00a0\u00bb de la configuration KentixONE du MultiSensor. Apr\u00e8s l&rsquo;enregistrement, le capteur fournit alors la valeur de mesure corrig\u00e9e. <\/td><td>L&rsquo;offset ne peut \u00eatre indiqu\u00e9 que par degr\u00e9s entiers, c&rsquo;est-\u00e0-dire sans d\u00e9cimale.<br\/>Cela donne une pr\u00e9cision de +\/- 0,5 degr\u00e9 pour la temp\u00e9rature.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Configuration avec KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">La configuration de l&rsquo;appareil s&rsquo;effectue via le navigateur web dans KentixONE. Du c\u00f4t\u00e9 du r\u00e9seau, l&rsquo;appareil doit \u00eatre accessible \u00e0 l&rsquo;instance centrale de KentixONE. Selon le type d&rsquo;appareil, une cl\u00e9 de communication ainsi que l&rsquo;adresse IP ou le nom DHCP de l&rsquo;instance centrale de KentixONE doivent \u00e9galement \u00eatre d\u00e9finis sur l&rsquo;appareil (MultiSensor, AccessManager, SmartPDU). En revanche, les cam\u00e9ras IP ou les modules IO peuvent \u00eatre directement int\u00e9gr\u00e9s dans KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">Vous trouverez toutes les informations sur le logiciel dans la section <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> et la documentation correspondante.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Avant de commencer la configuration, assurez-vous que le logiciel est \u00e0 jour sur tous les dispositifs Kentix compatibles r\u00e9seau. La version doit \u00eatre la m\u00eame sur tous les appareils. <br><strong>Vous pouvez \u00e0 tout moment effectuer une mise \u00e0 jour du logiciel pour votre instance principale KentixONE et tous les satellites connect\u00e9s via \u00ab\u00a0Syst\u00e8me - Mise \u00e0 jour\u00a0\u00bb.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">Vous trouverez des solutions aux questions fr\u00e9quemment pos\u00e9es sur les produits Kentix dans la section <a href=\"\/?ht_kb_category=faq\" target=\"_blank\" rel=\"noreferrer noopener\">FAQ g\u00e9n\u00e9rale.<\/a> <\/p>\n","protected":false},"excerpt":{"rendered":"<p>FICHE TECHNIQUE SmartPDU-2U Aper\u00e7u La SmartPDU est optimis\u00e9e pour alimenter des terminaux dans des armoires de donn\u00e9es et de r\u00e9seau tout en surveillant l&rsquo;alimentation, en collectant des donn\u00e9es de consommation et en contr\u00f4lant l&rsquo;environnement. Elle est g\u00e9n\u00e9ralement mont\u00e9e dans un rack de 19 pouces. Avec le PowerManager et le MultiSensor&#8230;<\/p>\n","protected":false},"author":6,"featured_media":13396,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[274],"ht-kb-tag":[],"class_list":["post-13392","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartpdu-vertical-horizontal"],"custom_fields":{"kentix_order_code":["KPMDU-RC-1600C13C19-2-16-H,KPMDU-NC-1600C13C19-1-16-H"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartpdu-vertical-horizontal","name":"SmartPDU - Vertical\/Horizontal","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-2HE-front-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13392"}],"version-history":[{"count":2,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13392\/revisions"}],"predecessor-version":[{"id":13425,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13392\/revisions\/13425"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media\/13396"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13392"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13392"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}