{"id":13383,"date":"2023-03-03T14:08:53","date_gmt":"2023-03-03T13:08:53","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/lecteur-mural-doorlock-wa2-manuel-dutilisation\/"},"modified":"2026-04-24T14:05:16","modified_gmt":"2026-04-24T12:05:16","slug":"lecteur-mural-doorlock-wa2-manuel-dutilisation","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/lecteur-mural-doorlock-wa2-manuel-dutilisation\/","title":{"rendered":"Lecteur mural DoorLock-WA2 - MANUEL D&rsquo;UTILISATION"},"content":{"rendered":"\n<h6 class=\"wp-block-heading\">Remplac\u00e9 par : KXC-WA2-V2-IP1, KXC-WA2-V2-IP2<\/h6>\n\n<pre class=\"wp-block-preformatted\"><a href=\"http:\/\/DoorLock-WA2%20%E2%80%93%20DATENBLATT\" target=\"_blank\" rel=\"noreferrer noopener\">FICHE TECHNIQUE KXC-WA2-IP1, KXC-WA2-IP2<\/a><\/pre>\n\n<p class=\"wp-block-paragraph\">Les lecteurs muraux IP permettent de d\u00e9verrouiller les portes sans contact avec une puce RFID et\/ou un code PIN comme authentification \u00e0 deux facteurs. Les lecteurs muraux IP se composent toujours du lecteur mural proprement dit et du <a rel=\"noreferrer noopener\" href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\">SmartRelay<\/a> de Kentix. Les lecteurs muraux sont connect\u00e9s \u00e0 l&rsquo;aide d&rsquo;un <a rel=\"noreferrer noopener\" href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\">SmartRelay<\/a> et peuvent ensuite \u00eatre reli\u00e9s \u00e0 un AccessManager (KXP16) via le mode Manager\/Satellite. Le lecteur mural est disponible en diff\u00e9rentes versions pour l&rsquo;int\u00e9rieur\/ext\u00e9rieur, en saillie\/encastr\u00e9 ou pour l&rsquo;installation dans des interphones.   <\/p>\n\n<p class=\"wp-block-paragraph\">Pour le fonctionnement des lecteurs muraux, un Kentix AccessManager pour lecteur de c\u00e2ble (KXP-2-RS) est n\u00e9cessaire. Vous trouverez des informations sur le relais et<strong> des sch\u00e9mas de c\u00e2blage, y compris des exemples,<\/strong> ici : <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">Kentix SmartRelay (KXP-2-RS)<\/a> <\/p>\n\n<p class=\"wp-block-paragraph\">Pour pouvoir activer des zones d&rsquo;alarme sur un lecteur mural, les conditions suivantes doivent \u00eatre remplies :<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Un AlarmManager doit \u00eatre connect\u00e9 dans la configuration de l&rsquo;AccessManager.<\/li>\n\n\n\n<li>L&rsquo;autorisation d&rsquo;activer des zones d&rsquo;alarme doit \u00eatre activ\u00e9e dans les param\u00e8tres de l&rsquo;utilisateur.<\/li>\n\n\n\n<li>Un code PIN et\/ou un jeton RFID doit \u00eatre attribu\u00e9 \u00e0 l&rsquo;utilisateur. La zone d&rsquo;alarme concern\u00e9e doit \u00eatre s\u00e9lectionn\u00e9e dans la configuration du lecteur mural. <\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Si les conditions sont remplies, il est possible d&rsquo;appuyer sur le bouton d&rsquo;armement ou de d\u00e9sarmement, puis de saisir le code PIN ou d&rsquo;effectuer l&rsquo;enregistrement avec le jeton. Si l&rsquo;action est r\u00e9ussie, la LED s&rsquo;allume en vert et la zone est activ\u00e9e. <\/p>\n\n<h2 class=\"wp-block-heading\">\u00c9l\u00e9ments de commande<\/h2>\n\n<h3 class=\"wp-block-heading\">WA2 Vue de face<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136.png\" alt=\"\" class=\"wp-image-2461\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-136-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">WA2 Vue de face<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-c86437cd-6b16-4185-a5b5-d8548268a703\"><ol class=\"fa-ul\"><li>Lecteur RFID int\u00e9gr\u00e9, toute la surface sert de surface de lecture<\/li><li>Touche de d\u00e9sarmement des zones d&rsquo;alarme (uniquement en association avec Kentix AlarmManager)<\/li><li>Bouton d&rsquo;armement des zones d&rsquo;alarme (uniquement en association avec Kentix AlarmManager)<\/li><\/ol><style>#heroic-styled-list-c86437cd-6b16-4185-a5b5-d8548268a703 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">WA2 \u00c9l\u00e9ments internes<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-1024x768.png\" alt=\"\" class=\"wp-image-2463\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-def65527-fbf5-4cc4-be1c-bc02ededac5d\"><ol class=\"fa-ul\"><li>Bornier 1, voir sch\u00e9ma de c\u00e2blage<\/li><li>Interrupteur DIP pour la configuration de l&rsquo;adresse<\/li><\/ol><style>#heroic-styled-list-def65527-fbf5-4cc4-be1c-bc02ededac5d li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h4 class=\"wp-block-heading\">Affectation des bornes WA2<\/h4>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Pince<\/th><th>Fonction<\/th><\/tr><tr><td>1<\/td><td>-<\/td><\/tr><tr><td>2<\/td><td>-<\/td><\/tr><tr><td>3<\/td><td>-<\/td><\/tr><tr><td>4<\/td><td>-<\/td><\/tr><tr><td>5<\/td><td>-<\/td><\/tr><tr><td>6<\/td><td>RS485 Data \u00ab\u00a0A<\/td><\/tr><tr><td>7<\/td><td>RS485 Data \u00ab\u00a0B<\/td><\/tr><tr><td>8<\/td><td>8-30 V\/DC<\/td><\/tr><tr><td>9  <\/td><td>GND<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA2 Affectation des bornes<\/figcaption><\/figure>\n\n<p class=\"wp-block-paragraph\">Interrupteur DIP WA2<\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Commutateur DIP<\/th><th>Fonction<\/th><\/tr><tr><td><strong>1<\/strong><\/td><td>Adresse 1 (1=ON, 2=OFF)<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Adresse 2 (1=OFF, 2=ON)<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>-<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>-<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>D\u00e9bit en bauds (5=ON)<\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>-<\/td><\/tr><tr><td><strong>7<\/strong><\/td><td>-<\/td><\/tr><tr><td><strong>8<\/strong><\/td><td>R\u00e9sistance terminale*<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA2 Commutateur DIP<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">*La r\u00e9sistance de terminaison est n\u00e9cessaire \u00e0 partir d&rsquo;une longueur de c\u00e2ble de 500m.<\/p>\n\n<h2 class=\"wp-block-heading\">Gestion des utilisateurs et des acc\u00e8s<\/h2>\n\n<p class=\"wp-block-paragraph\">La gestion des utilisateurs et des droits d&rsquo;acc\u00e8s se fait sur l&rsquo;unit\u00e9 principale de l&rsquo;installation avec KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">Vous trouverez toutes les informations sur le logiciel dans la section <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Remplac\u00e9 par : KXC-WA2-V2-IP1, KXC-WA2-V2-IP2 FICHE TECHNIQUE KXC-WA2-IP1, KXC-WA2-IP2 Les lecteurs muraux IP permettent de d\u00e9verrouiller les portes sans contact avec une puce RFID et\/ou un code PIN comme authentification \u00e0 deux facteurs. Les lecteurs muraux IP se composent toujours du lecteur mural proprement dit et du SmartRelay de Kentix&#8230;.<\/p>\n","protected":false},"author":2,"featured_media":13385,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[275],"ht-kb-tag":[],"class_list":["post-13383","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-archives-de-produits-smartaccess"],"custom_fields":{"kentix_order_code":["KXC-WA2-IP1, KXC-WA2-IP2"]},"categories":[{"slug":"archives-de-produits-smartaccess","name":"Archives de produits SmartAccess","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KXC-WA2-front-1-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13383"}],"version-history":[{"count":2,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13383\/revisions"}],"predecessor-version":[{"id":13424,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13383\/revisions\/13424"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media\/13385"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13383"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13383"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}