{"id":13296,"date":"2024-09-06T22:59:46","date_gmt":"2024-09-06T20:59:46","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/cxale-smartpdu-47u-jusqua-22kva-fiche-technique\/"},"modified":"2026-04-24T14:04:25","modified_gmt":"2026-04-24T12:04:25","slug":"cxale-smartpdu-47u-jusqua-22kva-fiche-technique","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/cxale-smartpdu-47u-jusqua-22kva-fiche-technique\/","title":{"rendered":"cXale SmartPDU 47U, (jusqu&rsquo;\u00e0 22kVA) - FICHE TECHNIQUE"},"content":{"rendered":"\n<figure class=\"wp-block-table is-style-regular\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Types<\/strong><\/th><th><strong>KPMDU-xx-xx-xx-2424-3-32-V<\/strong><\/th><th><strong>KPMDU-xx-xx-xx-2424-3-16-V<\/strong><\/th><th><strong>KPMDU-RC-xx-xx-2424-1-32-V<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Puissance nominale, tension<\/strong>\n        <\/td><td>jusqu&rsquo;\u00e0 22kVA, 230V<\/td><td>jusqu&rsquo;\u00e0 11kVA, 230V<\/td><td>jusqu&rsquo;\u00e0 7.3kVA, 230V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Fiche de connexion<\/strong>\n        <\/td><td>\n  Fiche CEE<strong>(ROUGE<\/strong>) selon IEC60309, 5 p\u00f4les,\n 32A\/230\/400V\n        <\/td><td>\n  Fiche CEE<strong>(ROUGE<\/strong>) selon IEC60309, 5 p\u00f4les,\n 16A\/230\/400V\n        <\/td><td>Fiche CEE<strong>(bleue<\/strong>) selon IEC60309, 3 p\u00f4les, 32A\/230V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>C\u00e2ble de connexion<\/strong>\n        <\/td><td>\n  Longueur 3m, c\u00e2ble en caoutchouc H07RN-F-5G6<br\/>Entr\u00e9e de c\u00e2ble sur PDU\n orientable \u00e0 \u00b145\u00b0.\n        <\/td><td>\n  Longueur 3m, c\u00e2ble en caoutchouc H07RN-F-5G2.5<br\/>Entr\u00e9e de c\u00e2ble sur PDU\n orientable \u00e0 \u00b145\u00b0.\n        <\/td><td>Longueur 3m, c\u00e2ble en caoutchouc H07RN-F-3G6<br\/>Entr\u00e9e de c\u00e2ble sur PDU orientable \u00e0 \u00b145\u00b0.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Prises de courant C13 (IEC60320)<\/strong>\n        <\/td><td>24<\/td><td>24<\/td><td>24<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Prises combin\u00e9es Cx (C13, C15, C19, C21\n IEC60320)<\/strong><\/td><td>24<\/td><td>24<\/td><td>24<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Verrouillage des prises<\/strong><\/td><td colspan=\"3\">IEC-LOCK pour C13\/Cx<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Disjoncteur-fusible avec\n couvercle rabattable<br\/>(courant nominal, caract\u00e9ristique, courant de court-circuit)<\/strong><\/td><td>6x 16A type C, 10kA<\/td><td>6x 10A type C, 10kA<\/td><td>6x 16A type C, 10kA<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Mesure du courant (\u00e9talonn\u00e9)<\/strong>\n        <\/td><td colspan=\"3\">\n  Mesure de courant int\u00e9gr\u00e9e et \u00e9talonn\u00e9e, pr\u00e9cision de classe B (MID, EN\n 50470-3)<br\/>Courant minimum 250mA, courant maximum 32A\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Mesure du courant diff\u00e9rentiel (RCM), en option<\/strong><\/td><td colspan=\"3\">Mesure du courant diff\u00e9rentiel sensible AC\/DC int\u00e9gr\u00e9e selon CEI 60664-1<br\/>\u00b1300mA\/100mA (RMS),\n Pr\u00e9cision &lt;0,2mA<br\/>Gamme de fr\u00e9quences DC 0..2kHz<br\/>Int\u00e9gr\u00e9 uniquement dans les types <strong>KPMDU-RC-<\/strong>&#8230;\n <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Protection contre les surtensions, en option<\/strong><\/td><td colspan=\"3\">Parafoudre modulaire type 2+3, courant de d\u00e9charge nominal (8\/20 \u00b5s) 20kA, courant de d\u00e9charge max. Courant de d\u00e9charge (8\/20 \u00b5s)\n 40kA<br\/>Int\u00e9gr\u00e9 uniquement dans les types <strong>KPMDU-RC-&#8230;-SP-&#8230;<\/strong>  <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Connectivit\u00e9<\/strong>\n        <\/td><td colspan=\"3\">Ethernet (10\/100MBit), PoE classe 3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Prise syst\u00e8me Kentix<\/strong> <strong>(type B)<\/strong>\n        <\/td><td colspan=\"3\">\n  RJ45 avec affectation sp\u00e9cifique Kentix pour les extensions du syst\u00e8me<br\/>2 x\n Digital Input (par ex. contacts de porte, d\u00e9tecteurs de fuite, alarmes externes)<br\/>1 x\n System BUS\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Communication et s\u00e9curit\u00e9<\/strong>\n        <\/td><td colspan=\"3\">\n  HTTPS (certificat), serveur web int\u00e9gr\u00e9, ReSt-API<br\/>Protocoles :\n SNMP V2\/3 (GET, TRAP), NTP, SMTP, DHCP, DNS, MODBUS-TCP\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Gestion<\/strong>\n        <\/td><td colspan=\"3\">Gestion de Main-Satellite via KentixONE<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Objets de mesure\/communication<\/strong>\n        <\/td><td colspan=\"3\">\n  Tension (V) L1\/L2\/L3\/total<br\/>Courant (A) L1\/L2\/L3\/Total<br\/>Consommation\n  (kWh) L1\/L2\/L3\/total<br\/>Puissance active (W) L1\/L2L3\/total<br\/>Puissance apparente\n  (VA) L1\/L2\/L3\/total<br\/>Puissance r\u00e9active (VAR) L1\/L2\/L3\/total<br\/>Qualit\u00e9 du r\u00e9seau - Harmonies\n  (%) THD U\/I - L1\/L2\/L3<br\/>Facteur d&rsquo;efficacit\u00e9 (cos phi)<br\/>Fr\u00e9quence (Hz)<br\/>Contr\u00f4le de phase\n  L1\/L2\/L3<br\/>Courant diff\u00e9rentiel AC<br\/>Courant diff\u00e9rentiel DC<br\/>\u00c9tat de la sauvegarde\n  L1\/L2\/L3<br\/>Temp\u00e9rature (\u00b0C)<br\/>Humidit\u00e9 relative (%)<br\/>Point de ros\u00e9e\n  (\u00b0C)<br\/>Vibration (G)<br\/>Qualit\u00e9 de l&rsquo;air COV (indice AIQ)\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>\u00c9cran (LCD)<\/strong>\n        <\/td><td colspan=\"3\">\n  \u00c9cran LCD \u00e9clair\u00e9 (puissance, courant, tension, consommation)\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Signalisation optique<\/strong>\n        <\/td><td colspan=\"3\">LED avec ROUGE\/VERT (fonctionnement, \u00e9tat d&rsquo;alarme\/d&rsquo;erreur)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Signalisation sonore<\/strong>\n        <\/td><td colspan=\"3\">\n  G\u00e9n\u00e9rateur de signaux \u00e0 80dB, 2,3kHz (conditions d&rsquo;alarme\/d&rsquo;erreur)\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>\u00c9tat d&rsquo;usine<\/strong>\n        <\/td><td colspan=\"3\">\n  Bouton de r\u00e9initialisation d&rsquo;usine<strong>(IP par d\u00e9faut : 192.168.100.226<\/strong>)\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Puissance dissip\u00e9e<\/strong>\n        <\/td><td colspan=\"3\">max. 40W (pleine charge) <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Bo\u00eetier<\/strong>\n        <\/td><td colspan=\"3\">T\u00f4le, rev\u00eatement en poudre RAL9005, classe de protection 1, indice de protection IP20, support de montage  <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"1\">\n          <strong>Taille<\/strong>\n        <\/td><td colspan=\"3\">2080 x 55,5 x 63 mm (h x l x p)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Poids<\/strong>\n        <\/td><td colspan=\"3\">environ 10 kg<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>Conditions environnementales<\/strong>\n        <\/td><td colspan=\"3\">\n  0\u00b0C \u00e0 60\u00b0C, humidit\u00e9 5-95%, temp\u00e9rature de stockage : -20\u00b0C \u00e0 60\u00b0C\n        <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Certification<\/strong><\/td><td colspan=\"3\">CE (2014\/30\/EG, 2014\/35\/EG, 2011\/65\/EU)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>S\u00e9curit\u00e9 \u00e9lectrique<\/strong>\n        <\/td><td colspan=\"3\">Contr\u00f4le DGUV-V3, VDE 0105-100<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\n          <strong>\u00c9tiquetage<\/strong>\n        <\/td><td colspan=\"3\">\n  Num\u00e9ro de s\u00e9rie (code-barres), zone d&rsquo;identification libre suppl\u00e9mentaire\n Face avant (60x30mm)\n        <\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Types KPMDU-xx-xx-xx-2424-3-32-V KPMDU-xx-xx-xx-2424-3-16-V KPMDU-RC-xx-xx-2424-1-32-V Puissance nominale, tension jusqu&rsquo;\u00e0 22kVA, 230V jusqu&rsquo;\u00e0 11kVA, 230V jusqu&rsquo;\u00e0 7.3kVA, 230V Fiche de connexion Fiche CEE(ROUGE) selon IEC60309, 5 p\u00f4les, 32A\/230\/400V Fiche CEE(ROUGE) selon IEC60309, 5 p\u00f4les, 16A\/230\/400V Fiche CEE(bleue) selon IEC60309, 3 p\u00f4les, 32A\/230V C\u00e2ble de connexion Longueur 3m, c\u00e2ble en caoutchouc H07RN-F-5G6Entr\u00e9e de&#8230;<\/p>\n","protected":false},"author":2,"featured_media":13299,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[253,256],"ht-kb-tag":[],"class_list":["post-13296","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-fiches-techniques-sur-le-materiel","ht_kb_category-fiches-techniques-2"],"custom_fields":{"kentix_order_code":["KPMDU-xx-xx-xx-2424-3-32-V, KPMDU-xx-xx-xx-2424-3-16-V, KPMDU-xx-xx-xx-2424-1-32-V"]},"categories":[{"slug":"fiches-techniques-sur-le-materiel","name":"Fiches techniques sur le mat\u00e9riel","shortName":""},{"slug":"fiches-techniques-2","name":"Fiches techniques","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/10\/kpmdu-scaled-cx-2424-150x4.webp","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13296"}],"version-history":[{"count":1,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13296\/revisions"}],"predecessor-version":[{"id":13300,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13296\/revisions\/13300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media\/13299"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13296"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13296"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}