{"id":13248,"date":"2023-02-14T14:36:44","date_gmt":"2023-02-14T13:36:44","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/multisensor-lan-ethernet-manuel-dutilisation\/"},"modified":"2026-04-24T14:11:22","modified_gmt":"2026-04-24T12:11:22","slug":"multisensor-lan-ethernet-manuel-dutilisation","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/multisensor-lan-ethernet-manuel-dutilisation\/","title":{"rendered":"MultiSensor-LAN (Ethernet) - MANUEL D&rsquo;UTILISATION"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/fr\/knowledge-base\/multisensor-lan-fiche-technique-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">FICHE TECHNIQUE MULTISENSOR-LAN<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">KentixONE Mode de fonctionnement<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">SiteManager Op\u00e9ration<\/th><th class=\"has-text-align-center\" data-align=\"center\">Fonctionnement autonome<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/betriebsarten\/\">Plus d&rsquo;informations sur le mode de fonctionnement<\/a><\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Aper\u00e7u<\/h2>\n\n<p class=\"wp-block-paragraph\">Le MultiSensor-LAN int\u00e8gre un grand nombre de capteurs individuels dans un appareil compact et surveille leurs valeurs de mesure. Le MultiSensor-LAN est optimis\u00e9 pour la surveillance d&rsquo;espaces ferm\u00e9s et est g\u00e9n\u00e9ralement mont\u00e9 sur ou au niveau du plafond de la pi\u00e8ce. Le MultiSensor-LAN peut \u00eatre mis en r\u00e9seau et est aliment\u00e9 par Power over Ethernet (PoE).  <\/p>\n\n<p class=\"wp-block-paragraph\">Le MultiSensor-LAN peut \u00eatre utilis\u00e9 comme appareil individuel (mode de fonctionnement : Stand-Alone Device) ou en r\u00e9seau (mode de fonctionnement : Satellite Device) avec d&rsquo;autres MultiSensor-LAN et d&rsquo;autres appareils Kentix. Le logiciel KentixONE est d\u00e9j\u00e0 int\u00e9gr\u00e9 via le serveur web int\u00e9gr\u00e9 (HTTPS). La configuration s&rsquo;effectue via un navigateur Web et, selon le mode de fonctionnement, localement sur le MultiSensor-LAN lui-m\u00eame (mode de fonctionnement : Stand-Alone Device) ou sur une instance centrale comme le SiteManager ou le AlarmManager (mode de fonctionnement : Satellite Device).  <\/p>\n\n<p class=\"wp-block-paragraph\">Outre l&rsquo;interface r\u00e9seau Ethernet, le MultiSensor-LAN dispose d&rsquo;une interface radio BLE (2,4GHz). Celle-ci permet de connecter d&rsquo;autres capteurs radio Kentix en mode Satellite Device. Le MultiSensor-LAN fonctionne alors en outre comme une passerelle radio Ethernet, ce qui permet de cr\u00e9er tr\u00e8s facilement des r\u00e9seaux de capteurs stables. Selon la structure du b\u00e2timent, les capteurs radio peuvent \u00eatre r\u00e9partis dans un rayon allant jusqu&rsquo;\u00e0 20 m\u00e8tres.   <\/p>\n\n<h2 class=\"wp-block-heading\">Consignes de s\u00e9curit\u00e9<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">L&rsquo;installation et la mise en service ne doivent \u00eatre effectu\u00e9es que par un personnel sp\u00e9cialis\u00e9 et form\u00e9, conform\u00e9ment au mode d&#8217;emploi.<br>Aucune modification de quelque nature que ce soit, \u00e0 l&rsquo;exception de celles d\u00e9crites dans un mode d&#8217;emploi correspondant, n&rsquo;est autoris\u00e9e sur les produits de Kentix GmbH.<br>Lors de l&rsquo;installation d&rsquo;appareils Kentix, certains degr\u00e9s de protection doivent \u00eatre garantis.<br>Respectez \u00e0 cet effet les prescriptions en vigueur pour les installations dans l&rsquo;environnement concern\u00e9.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>Les instructions doivent \u00eatre transmises \u00e0 l&rsquo;utilisateur par la personne qui proc\u00e8de \u00e0 l&rsquo;installation.<br>Kentix d\u00e9cline toute responsabilit\u00e9 en cas d&rsquo;endommagement des appareils ou des composants suite \u00e0 un montage incorrect. Aucune responsabilit\u00e9 n&rsquo;est assum\u00e9e en cas d&rsquo;unit\u00e9s mal programm\u00e9es.<br>Si des dysfonctionnements, des dommages mat\u00e9riels ou autres surviennent, Kentix n&rsquo;est pas responsable. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Utilisation des produits, transport et stockage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Prot\u00e9ger l&rsquo;appareil contre l&rsquo;humidit\u00e9, la salet\u00e9 et les dommages pendant le transport, le stockage et l&rsquo;utilisation<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Produits aliment\u00e9s par batterie<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">N&rsquo;utilisez pas les produits dans des zones \u00e0 risque d&rsquo;explosion.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>L&rsquo;installation ainsi que le remplacement des piles ne doivent \u00eatre effectu\u00e9s que par un personnel qualifi\u00e9 et form\u00e9, conform\u00e9ment aux instructions.<br>Ne chargez pas, ne court-circuitez pas, n&rsquo;ouvrez pas et ne chauffez pas les piles.<br>Lors de la mise en place des piles, veillez \u00e0 respecter la polarit\u00e9.<br>Les appareils doivent toujours \u00eatre aliment\u00e9s par les piles pr\u00e9vues pour le produit.<br>Lors du remplacement des piles, remplacez toujours toutes les piles.<br>\u00c9liminez les piles usag\u00e9es ou us\u00e9es de mani\u00e8re appropri\u00e9e.<br>Conservez les piles hors de port\u00e9e des enfants.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Le fonctionnement des appareils Kentix doit \u00eatre contr\u00f4l\u00e9 dans le cadre d&rsquo;une maintenance annuelle.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>\u00c9limination des d\u00e9chets<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Les appareils \u00e9lectriques et les piles doivent \u00eatre \u00e9limin\u00e9s s\u00e9par\u00e9ment des d\u00e9chets m\u00e9nagers.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">\u00c9l\u00e9ments de commande<\/h2>\n\n<h3 class=\"wp-block-heading\">Face avant<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front.jpeg\" alt=\"\" class=\"wp-image-3668\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-100x75.jpeg 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-dcab0467-9ec1-4b54-89d0-7944733d50e6\"><ol class=\"fa-ul\"><li>LED d&rsquo;\u00e9tat : <br><strong>VERT : <\/strong>POWER OK, pas d&rsquo;alarmes en cours<br> ROUGE<strong>: <\/strong>POWER OK, alarmes en cours<\/li><li>Capteur de mouvement PIR 360<\/li><\/ol><style>#heroic-styled-list-dcab0467-9ec1-4b54-89d0-7944733d50e6 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Verso<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-1024x768.png\" alt=\"\" class=\"wp-image-1752\" style=\"width:604px;height:453px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">MultiSensor LAN Vue arri\u00e8re<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-4990a502-00ab-42b6-ba33-52c7e0bc7aa2\"><ol class=\"fa-ul\"><li>Bouton de r\u00e9initialisation<\/li><li>Support de montage<\/li><li>Informations sur les param\u00e8tres par d\u00e9faut<\/li><\/ol><style>#heroic-styled-list-4990a502-00ab-42b6-ba33-52c7e0bc7aa2 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Connexions<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-1024x768.png\" alt=\"\" class=\"wp-image-1754\" style=\"width:504px;height:378px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Vue MultiSensor-LAN Connecteurs<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e49c4d8d-70ff-43cf-82bc-065115402805\"><ol class=\"fa-ul\"><li>Port syst\u00e8me Kentix (type A)<\/li><li>Port Ethernet avec Power over Ethernet (100MBit, PoE classe 2)<\/li><li>Fente pour carte MicroSD<\/li><\/ol><style>#heroic-styled-list-e49c4d8d-70ff-43cf-82bc-065115402805 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h2 class=\"wp-block-heading\">Connexion d&rsquo;extensions au port syst\u00e8me<\/h2>\n\n<p class=\"wp-block-paragraph\">Le port syst\u00e8me Kentix permet de connecter des composants syst\u00e8me suppl\u00e9mentaires tels que des capteurs de fuite, des contacts de porte ou des alarmes externes d&rsquo;onduleurs ou de climatiseurs. Le port syst\u00e8me dispose de 2 entr\u00e9es num\u00e9riques et de 2 sorties num\u00e9riques disponibles via une prise RJ45.   <\/p>\n\n<p class=\"wp-block-paragraph\">Un module d&rsquo;extension (ORDER-CODE : KIO3) est n\u00e9cessaire pour connecter des alarmes externes. Il est possible d&rsquo;y connecter 2 contacts sans potentiel et 2 relais inverseurs. <\/p>\n\n<p class=\"wp-block-paragraph\">Un c\u00e2ble patch r\u00e9seau standard (non blind\u00e9\/blind\u00e9) d&rsquo;une longueur maximale de 20 m peut \u00eatre utilis\u00e9 comme connexion par c\u00e2ble entre le port syst\u00e8me Kentix et le composant syst\u00e8me.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">Le port syst\u00e8me Kentix n&rsquo;est pas une connexion r\u00e9seau. \u00c9vitez de le connecter \u00e0 des ports r\u00e9seau, en particulier \u00e0 des appareils PoE. Le port est un port d&rsquo;extension sp\u00e9cifique \u00e0 Kentix et ne peut \u00eatre \u00e9tendu qu&rsquo;avec des composants con\u00e7us \u00e0 cet effet.<br>Les broches 4\/5\/8 ne sont lib\u00e9r\u00e9es que pour un usage interne et ne doivent pas \u00eatre connect\u00e9es.    <\/p>\n\n<p class=\"wp-block-paragraph\">L&rsquo;affectation du port syst\u00e8me<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Port syst\u00e8me (type : RJ45)<\/th><th>Affectation des contacts<\/th><\/tr><\/thead><tbody><tr><td><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"177\" class=\"wp-image-1399\" style=\"width: 150px;\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort.png\" alt=\"\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort.png 598w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-339x400.png 339w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-127x150.png 127w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-42x50.png 42w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-51x60.png 51w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-85x100.png 85w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/td><td>1. tension syst\u00e8me interne (GND) - Pas pour utilisation <strong> externe*<\/strong><br\/>2. sortie 1 (collecteur ouvert, max. 100mA)<br\/>3. sortie 2 (collecteur ouvert, max. 100mA)<br\/>4. tension externe \/ BUS (selon le type d&rsquo;appareil)<br\/>5. tension externe \/BUS (selon le type d&rsquo;appareil)<br\/>6. Entr\u00e9e 1 (circuit libre de potentiel)<br\/>7. Entr\u00e9e 2 (circuit libre de potentiel)<br\/>8. Tension interne du syst\u00e8me (5\/24VDC) - Non destin\u00e9 \u00e0 une utilisation <strong> externe*<\/strong><br\/><br\/> *<strong> Ces connecteurs sont destin\u00e9s \u00e0 une utilisation interne uniquement.<\/strong><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Affectation du port syst\u00e8me Kentix<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Connexion d&rsquo;un capteur de fuite au port syst\u00e8me<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001.png\" alt=\"\" class=\"wp-image-10003\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-3833ef4d-a097-43a5-99e5-317612c23dcd\"><ol class=\"fa-ul\"><li>Capteur de fuite<\/li><li>MultiSensor<\/li><\/ol><style>#heroic-styled-list-3833ef4d-a097-43a5-99e5-317612c23dcd li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">Le capteur de fuite est directement connect\u00e9 au port syst\u00e8me du MultiSensor.<\/p>\n\n<h3 class=\"wp-block-heading\">Connexion d&rsquo;une sir\u00e8ne d&rsquo;alarme au port syst\u00e8me<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002.png\" alt=\"\" class=\"wp-image-10005\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-7dca2e42-ad9e-4c7c-a95a-eac7f7341248\"><ol class=\"fa-ul\"><li>Alimentation \u00e9lectrique 24V DC<\/li><li>Sir\u00e8ne d&rsquo;alarme<\/li><li>MultiSensor<\/li><li>KIO2<\/li><li>Adaptateur en T RJ45<\/li><\/ol><style>#heroic-styled-list-7dca2e42-ad9e-4c7c-a95a-eac7f7341248 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">La sir\u00e8ne d&rsquo;alarme est aliment\u00e9e en 24V DC par le module d&rsquo;extension KIO2 et un bloc d&rsquo;alimentation. De plus, la sir\u00e8ne d&rsquo;alarme est reli\u00e9e au MultiSensor via l&rsquo;adaptateur RJ45 T. <\/p>\n\n<h3 class=\"wp-block-heading\">Connexion d&rsquo;un capteur de fuite et d&rsquo;une sir\u00e8ne d&rsquo;alarme au port syst\u00e8me<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003.png\" alt=\"\" class=\"wp-image-10007\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-88b55f8b-6366-4b22-9fc8-3980943971c4\"><ol class=\"fa-ul\"><li>Alimentation \u00e9lectrique 24V DC<\/li><li>Sir\u00e8ne d&rsquo;alarme<\/li><li>Capteur de fuite<\/li><li>MultiSensor<\/li><li>KIO2<\/li><li>Adaptateur en T RJ45<\/li><li>Adaptateur en T RJ45<\/li><\/ol><style>#heroic-styled-list-88b55f8b-6366-4b22-9fc8-3980943971c4 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">La sir\u00e8ne d&rsquo;alarme est aliment\u00e9e en 24V DC par le module d&rsquo;extension KIO2 et un bloc d&rsquo;alimentation. En outre, la sir\u00e8ne d&rsquo;alarme est connect\u00e9e au MultiSensor via deux adaptateurs en T RJ45. Le deuxi\u00e8me adaptateur en T est \u00e9galement utilis\u00e9 pour connecter le capteur de fuite.  <\/p>\n\n<h2 class=\"wp-block-heading\">Param\u00e8tres d&rsquo;usine<\/h2>\n\n<p class=\"wp-block-paragraph\">Pour la configuration initiale, utilisez l&rsquo;adresse IP imprim\u00e9e sur l&rsquo;appareil ou l&rsquo;adresse attribu\u00e9e par DHCP dans un navigateur web (HTTPS). Veuillez tenir compte des param\u00e8tres r\u00e9seau de votre PC connect\u00e9. <\/p>\n\n<p class=\"wp-block-paragraph\">Aper\u00e7u des adresses IP d&rsquo;usine :<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-white-background-color has-background\"><tbody><tr><td><strong>SiteManager et AlarmManager<\/strong><\/td><td>192.168.100.222<\/td><\/tr><tr><td><strong>MultiSensor<\/strong><\/td><td>192.168.100.223<\/td><\/tr><tr><td><strong>AccessManager<\/strong><\/td><td>192.168.100.224<\/td><\/tr><tr><td><strong>PowerManager<\/strong><\/td><td>192.168.100.225<\/td><\/tr><tr><td><strong>SmartPDU<\/strong><\/td><td>192.168.100.226<\/td><\/tr><tr><td><strong>Capteur de fuite<\/strong><\/td><td>192.168.100.227<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Adresses IP d&rsquo;usine, masque de sous-r\u00e9seau : 255.255.255.0<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">Pour les appareils avec une version de firmware inf\u00e9rieure \u00e0 8.x.x, les donn\u00e9es de connexion pour le compte administrateur par d\u00e9faut sont : admin \/ password<\/p>\n\n<h2 class=\"wp-block-heading\">R\u00e9initialiser les param\u00e8tres d&rsquo;usine<\/h2>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3\"><ol class=\"fa-ul\"><li>Red\u00e9marrer l&rsquo;appareil (d\u00e9connecter et reconnecter l&rsquo;alimentation)<\/li><li>Le voyant d&rsquo;\u00e9tat s&rsquo;allume bri\u00e8vement et s&rsquo;\u00e9teint.<\/li><li>D\u00e8s que la LED d&rsquo;\u00e9tat s&rsquo;allume en vert fixe, maintenez le bouton de r\u00e9initialisation enfonc\u00e9 pendant 15 secondes jusqu&rsquo;\u00e0 ce que l&rsquo;appareil \u00e9mette un signal sonore de confirmation.<\/li><li>L&rsquo;appareil charge les param\u00e8tres d&rsquo;usine et effectue un red\u00e9marrage.<\/li><li>Apr\u00e8s environ 2 minutes, l&rsquo;appareil est accessible avec les param\u00e8tres d&rsquo;usine.<\/li><\/ol><style>#heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Tous les param\u00e8tres et donn\u00e9es existants seront irr\u00e9m\u00e9diablement supprim\u00e9s !<\/strong><br><strong>Nous vous recommandons de sauvegarder r\u00e9guli\u00e8rement votre syst\u00e8me<\/strong>.<\/p>\n\n<h2 class=\"wp-block-heading\">Instructions de montage<\/h2>\n\n<p class=\"wp-block-paragraph\">Les MultiSensors de Kentix sont \u00e9quip\u00e9s de diff\u00e9rents capteurs individuels. Afin de garantir une \u00e9valuation optimale et une coop\u00e9ration fonctionnelle des capteurs, veuillez respecter les instructions de montage de base suivantes : <\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--noicon\">Ne pas installer au-dessus de radiateurs ou de bouches d&rsquo;air ou de sources directes de chaleur\/froid<br>-\u00c9viter les objets en mouvement tels que les ventilateurs, les plantes, les arbres, les drapeaux, etc. dans le champ de d\u00e9tection<br>-Ne pas couvrir le capteur. Le capteur PIR a toujours besoin d&rsquo;un contact visuel direct pour \u00eatre d\u00e9tect\u00e9<br>-Ne pas installer dans le flux d&rsquo;air direct des bouches d&rsquo;air conditionn\u00e9. <\/p>\n\n<h2 class=\"wp-block-heading\">Zone de couverture du d\u00e9tecteur de mouvement PIR int\u00e9gr\u00e9<\/h2>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-1024x768.png\" alt=\"\" class=\"wp-image-2622\" width=\"623\" height=\"467\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik.png 2048w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><figcaption class=\"wp-element-caption\">Zone de d\u00e9tection du PIR<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--noicon is-style-info\"><a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/fr\/knowledge-base\/a-quoi-faut-il-faire-attention-lors-de-linstallation-des-multicapteurs\/\" target=\"_blank\">Plus d&rsquo;informations sur le montage des MultiSensors ici.<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">\u00c9talonnage de la mesure de la temp\u00e9rature ambiante<\/h2>\n\n<p class=\"wp-block-paragraph\">Les MultiSENSORS de Kentix enregistrent toutes les valeurs environnementales importantes d&rsquo;une pi\u00e8ce, entre autres la temp\u00e9rature ambiante. Afin d&rsquo;obtenir une temp\u00e9rature aussi pr\u00e9cise que possible et un d\u00e9clenchement d&rsquo;alarme en cas de d\u00e9passement de la valeur limite de la temp\u00e9rature ambiante, il est recommand\u00e9 de calibrer la mesure de la temp\u00e9rature \u00e0 l&rsquo;endroit d\u00e9finitif de l&rsquo;installation. Cela est particuli\u00e8rement n\u00e9cessaire pour les capteurs avec connexion Ethernet (PoE), car une certaine chaleur propre fausse la mesure. Pour les multicapteurs aliment\u00e9s par radio et par batterie, l&rsquo;influence de la chaleur intrins\u00e8que n&rsquo;existe pas.   <\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Les MultiSensors de Kentix ne sont pas des appareils de mesure \u00e9talonn\u00e9s, mais des appareils d&rsquo;alarme dont la pr\u00e9cision de mesure est amplement suffisante pour signaler et documenter de mani\u00e8re fiable les d\u00e9passements de valeurs limites.<\/p>\n\n<p class=\"wp-block-paragraph\">Pour obtenir n\u00e9anmoins un bon r\u00e9sultat de mesure avec des valeurs de mesure compr\u00e9hensibles en cas d&rsquo;alarme, le MultiSensor doit \u00eatre calibr\u00e9 apr\u00e8s l&rsquo;installation en fonction de l&rsquo;endroit o\u00f9 il est install\u00e9. Pour ce faire, la temp\u00e9rature doit \u00eatre mesur\u00e9e de mani\u00e8re comparative \u00e0 proximit\u00e9 imm\u00e9diate (\u00e0 une distance d&rsquo;environ 5 \u00e0 10 cm) du MultiSensor \u00e0 l&rsquo;aide d&rsquo;un thermom\u00e8tre ambiant aussi pr\u00e9cis que possible. En cas de diff\u00e9rence de temp\u00e9rature entre le MultiSensor et le thermom\u00e8tre, la valeur de temp\u00e9rature peut \u00eatre corrig\u00e9e. Pour ce faire, la diff\u00e9rence de temp\u00e9rature d\u00e9termin\u00e9e entre le MultiSensor et le thermom\u00e8tre ambiant est introduite dans le logiciel KentixONE en tant que d\u00e9calage de correction. La correction a en outre une influence directe sur la mesure de l&rsquo;humidit\u00e9 relative de l&rsquo;air ainsi que sur le calcul du point de ros\u00e9e du MultiSensor.    <\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u00c9tape<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Installer le MultiSensor \u00e0 destination.<\/td><td>La position et l&rsquo;orientation du capteur ne doivent plus \u00eatre modifi\u00e9es par la suite.<br\/>Tenez compte des points suivants :<br\/>- Montez le capteur avec l&rsquo;ouverture d&rsquo;air en X vers le bas<br\/>- Ne le montez pas dans un flux d&rsquo;air<br\/>- Les ouvertures d&rsquo;a\u00e9ration du capteur doivent \u00eatre libres.<\/td><\/tr><tr><td>Effectuer la configuration du MultiSensor avec Kentix ONE.<\/td><td><\/td><\/tr><tr><td>Au plus t\u00f4t 30 minutes apr\u00e8s la mise en service<br\/>, ajustez la temp\u00e9rature du MultiSensor avec la temp\u00e9rature ambiante.<\/td><td>Pour ce faire, mesurez la temp\u00e9rature \u00e0 l&rsquo;aide d&rsquo;un thermom\u00e8tre de r\u00e9f\u00e9rence externe plac\u00e9 \u00e0 proximit\u00e9 imm\u00e9diate, \u00e0 environ 5-10 cm du MultiSensor. Il convient de noter que ce thermom\u00e8tre s&rsquo;acclimate \u00e9galement \u00e0 la pi\u00e8ce et n&rsquo;indique la temp\u00e9rature ambiante correcte qu&rsquo;apr\u00e8s quelques minutes. <\/td><\/tr><tr><td>Si une diff\u00e9rence est constat\u00e9e entre le MultiSensor et le thermom\u00e8tre, celle-ci peut \u00eatre saisie dans le champ \u00ab\u00a0Offset\u00a0\u00bb de la configuration KentixONE du MultiSensor. Apr\u00e8s l&rsquo;enregistrement, le capteur fournit alors la valeur de mesure corrig\u00e9e. <\/td><td>L&rsquo;offset ne peut \u00eatre indiqu\u00e9 que par degr\u00e9s entiers, c&rsquo;est-\u00e0-dire sans d\u00e9cimale.<br\/>Cela donne une pr\u00e9cision de +\/- 0,5 degr\u00e9 pour la temp\u00e9rature.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Configuration avec KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">La configuration de l&rsquo;appareil s&rsquo;effectue via le navigateur web dans KentixONE. Du c\u00f4t\u00e9 du r\u00e9seau, l&rsquo;appareil doit \u00eatre accessible \u00e0 l&rsquo;instance centrale de KentixONE. Selon le type d&rsquo;appareil, une cl\u00e9 de communication ainsi que l&rsquo;adresse IP ou le nom DHCP de l&rsquo;instance centrale de KentixONE doivent \u00e9galement \u00eatre d\u00e9finis sur l&rsquo;appareil (MultiSensor, AccessManager, SmartPDU). En revanche, les cam\u00e9ras IP ou les modules IO peuvent \u00eatre directement int\u00e9gr\u00e9s dans KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">Vous trouverez toutes les informations sur le logiciel dans la section <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> et la documentation correspondante.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Avant de commencer la configuration, assurez-vous que le logiciel est \u00e0 jour sur tous les dispositifs Kentix compatibles r\u00e9seau. La version doit \u00eatre la m\u00eame sur tous les appareils. <br><strong>Vous pouvez \u00e0 tout moment effectuer une mise \u00e0 jour du logiciel pour votre instance principale KentixONE et tous les satellites connect\u00e9s via \u00ab\u00a0Syst\u00e8me - Mise \u00e0 jour\u00a0\u00bb.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>FICHE TECHNIQUE MULTISENSOR-LAN Aper\u00e7u Le MultiSensor-LAN int\u00e8gre un grand nombre de capteurs individuels dans un appareil compact et surveille leurs valeurs de mesure. Le MultiSensor-LAN est optimis\u00e9 pour la surveillance d&rsquo;espaces ferm\u00e9s et est g\u00e9n\u00e9ralement mont\u00e9 sur ou au niveau du plafond de la pi\u00e8ce. Le MultiSensor-LAN peut \u00eatre mis&#8230;<\/p>\n","protected":false},"author":6,"featured_media":13242,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[248],"ht-kb-tag":[],"class_list":["post-13248","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-ethernet-multisensors"],"custom_fields":{"kentix_order_code":["KMS-LAN-B, KMS-LAN-W, KMS-LAN-B-BLE, KMS-LAN-W-BLE"],"kentix_skill_level":["1"]},"categories":[{"slug":"ethernet-multisensors","name":"Ethernet MultiSensors","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-B-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13248","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13248"}],"version-history":[{"count":4,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13248\/revisions"}],"predecessor-version":[{"id":13991,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13248\/revisions\/13991"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media\/13242"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13248"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13248"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}