{"id":13185,"date":"2023-09-07T11:29:34","date_gmt":"2023-09-07T09:29:34","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/boite-de-distribution-pour-doorlock-ra4-manuel-dutilisation\/"},"modified":"2026-04-24T14:11:11","modified_gmt":"2026-04-24T12:11:11","slug":"boite-de-distribution-pour-doorlock-ra4-manuel-dutilisation","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/fr\/knowledge-base\/boite-de-distribution-pour-doorlock-ra4-manuel-dutilisation\/","title":{"rendered":"Bo\u00eete de distribution pour DoorLock-RA4 - MANUEL D&rsquo;UTILISATION"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/fr\/knowledge-base\/doorlock-ra4-fiche-technique\/\" target=\"_blank\" rel=\"noreferrer noopener\">FICHE TECHNIQUE KXC-RA4<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Aper\u00e7u<\/h2>\n\n<p class=\"wp-block-paragraph\">Le bo\u00eetier de distribution DoorLock-RA4-DB-BUS est l&rsquo;unit\u00e9 de connexion centrale pour deux leviers de rack (KXC-RA4-IPx) et deux contacts de porte (KDC1-W) dans chaque rack. En outre, le bo\u00eetier de distribution sert de connexion de bus de rack \u00e0 rack pour un maximum de 8 racks ou 16 leviers de rack. Le bo\u00eetier de distribution est fix\u00e9 dans le rack lui-m\u00eame, tous les composants sont enfich\u00e9s sans serrage via des prises RJ45.  <\/p>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-d0689af4-ff68-4ea6-81ac-8717b2444459\"><ol class=\"fa-ul\"><li>Connexion de deux contacts de porte<\/li><li>Connexion de deux DoorLock-RA4<\/li><li>Connexion d&rsquo;autres bo\u00eetiers de distribution<\/li><\/ol><style>#heroic-styled-list-d0689af4-ff68-4ea6-81ac-8717b2444459 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">Le bo\u00eetier de distribution se connecte soit directement au poste distant du DoorLock-Ra4 (AccessManager ou SmartPDU), soit \u00e0 un autre bo\u00eetier de distribution.<\/p>\n\n<h2 class=\"wp-block-heading\">Consignes de s\u00e9curit\u00e9<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">L&rsquo;installation et la mise en service ne doivent \u00eatre effectu\u00e9es que par un personnel sp\u00e9cialis\u00e9 et form\u00e9, conform\u00e9ment au mode d&#8217;emploi.<br>Aucune modification de quelque nature que ce soit, \u00e0 l&rsquo;exception de celles d\u00e9crites dans un mode d&#8217;emploi correspondant, n&rsquo;est autoris\u00e9e sur les produits de Kentix GmbH.<br>Lors de l&rsquo;installation d&rsquo;appareils Kentix, certains degr\u00e9s de protection doivent \u00eatre garantis.<br>Respectez \u00e0 cet effet les prescriptions en vigueur pour les installations dans l&rsquo;environnement concern\u00e9.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>Les instructions doivent \u00eatre transmises \u00e0 l&rsquo;utilisateur par la personne qui proc\u00e8de \u00e0 l&rsquo;installation.<br>Kentix d\u00e9cline toute responsabilit\u00e9 en cas d&rsquo;endommagement des appareils ou des composants suite \u00e0 un montage incorrect. Aucune responsabilit\u00e9 n&rsquo;est assum\u00e9e en cas d&rsquo;unit\u00e9s mal programm\u00e9es.<br>Si des dysfonctionnements, des dommages mat\u00e9riels ou autres surviennent, Kentix n&rsquo;est pas responsable. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Utilisation des produits, transport et stockage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Prot\u00e9ger l&rsquo;appareil contre l&rsquo;humidit\u00e9, la salet\u00e9 et les dommages pendant le transport, le stockage et l&rsquo;utilisation<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Produits aliment\u00e9s par batterie<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">N&rsquo;utilisez pas les produits dans des zones \u00e0 risque d&rsquo;explosion.<br>N&rsquo;utilisez les produits que dans la plage de temp\u00e9rature d\u00e9finie.<br>L&rsquo;installation ainsi que le remplacement des piles ne doivent \u00eatre effectu\u00e9s que par un personnel qualifi\u00e9 et form\u00e9, conform\u00e9ment aux instructions.<br>Ne chargez pas, ne court-circuitez pas, n&rsquo;ouvrez pas et ne chauffez pas les piles.<br>Lors de la mise en place des piles, veillez \u00e0 respecter la polarit\u00e9.<br>Les appareils doivent toujours \u00eatre aliment\u00e9s par les piles pr\u00e9vues pour le produit.<br>Lors du remplacement des piles, remplacez toujours toutes les piles.<br>\u00c9liminez les piles usag\u00e9es ou us\u00e9es de mani\u00e8re appropri\u00e9e.<br>Conservez les piles hors de port\u00e9e des enfants.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Le fonctionnement des appareils Kentix doit \u00eatre contr\u00f4l\u00e9 dans le cadre d&rsquo;une maintenance annuelle.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>\u00c9limination des d\u00e9chets<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Les appareils \u00e9lectriques et les piles doivent \u00eatre \u00e9limin\u00e9s s\u00e9par\u00e9ment des d\u00e9chets m\u00e9nagers.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Connexions<\/h2>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite.png\" alt=\"\" class=\"wp-image-7229\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Vorderseite-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-41a935f9-bcb1-47c3-bd38-e878ac70ec0c\"><ol class=\"fa-ul\"><li>Connecteur pour DoorLock-RA4<\/li><li>Connexion pour contact de porte KDC1-W<\/li><\/ol><style>#heroic-styled-list-41a935f9-bcb1-47c3-bd38-e878ac70ec0c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">L&rsquo;\u00e9valuation du contact de porte se fait sur le DoorLock. C&rsquo;est pourquoi il est imp\u00e9ratif qu&rsquo;un DoorLock soit \u00e9galement connect\u00e9 au bo\u00eetier de distribution pour chaque contact de porte. <\/p>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite.png\" alt=\"\" class=\"wp-image-7227\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Rueckseite-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-895b55bb-6a7c-48f6-94f8-2a2d31b213ef\"><ol class=\"fa-ul\"><li>Connexion au bo\u00eetier de distribution suivant<\/li><li>Interrupteur Dip (tous les interrupteurs doivent \u00eatre sur ON)<\/li><li>Connexion au poste distant ou au bo\u00eetier de distribution pr\u00e9c\u00e9dent<\/li><\/ol><style>#heroic-styled-list-895b55bb-6a7c-48f6-94f8-2a2d31b213ef li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Affectation des ports<\/h3>\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets.png\" alt=\"\" class=\"wp-image-11162\" style=\"width:1500px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_sockets-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h2 class=\"wp-block-heading\" id=\"systemtopologie\">Exemple de connexion<\/h2>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp.png\" alt=\"\" class=\"wp-image-7252\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4-DB-BUS_Anschlussbsp-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-32efa996-1b00-4907-ba7e-e1182979e78d\"><ol class=\"fa-ul\"><li>Connexion au poste distant ou au bo\u00eetier de distribution pr\u00e9c\u00e9dent<\/li><li>Connexion au bo\u00eetier de distribution suivant<\/li><li>DoorLock-RA4<\/li><li>Contact de porte KDC1-W<\/li><\/ol><style>#heroic-styled-list-32efa996-1b00-4907-ba7e-e1182979e78d li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n","protected":false},"excerpt":{"rendered":"<p>FICHE TECHNIQUE KXC-RA4 Aper\u00e7u Le bo\u00eetier de distribution DoorLock-RA4-DB-BUS est l&rsquo;unit\u00e9 de connexion centrale pour deux leviers de rack (KXC-RA4-IPx) et deux contacts de porte (KDC1-W) dans chaque rack. En outre, le bo\u00eetier de distribution sert de connexion de bus de rack \u00e0 rack pour un maximum de 8 racks&#8230;<\/p>\n","protected":false},"author":6,"featured_media":13188,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[265],"ht-kb-tag":[],"class_list":["post-13185","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-filaire-pour-les-racks-informatiques"],"custom_fields":{"kentix_order_code":["KXC-RA4-DB-BUS, KXC-RA4-DB-BUS-SET"]},"categories":[{"slug":"smartaccess-bus-filaire-pour-les-racks-informatiques","name":"SmartAccess (BUS) filaire pour les racks informatiques","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/kxc-ra4-db-bus-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/comments?post=13185"}],"version-history":[{"count":4,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13185\/revisions"}],"predecessor-version":[{"id":13917,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb\/13185\/revisions\/13917"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media\/13188"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/media?parent=13185"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=13185"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=13185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}