{"id":9923,"date":"2024-06-18T14:00:37","date_gmt":"2024-06-18T12:00:37","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/wall-reader-bus-doorlock-wa7-v2-manual\/"},"modified":"2025-11-14T09:51:24","modified_gmt":"2025-11-14T08:51:24","slug":"wall-reader-bus-doorlock-wa7-v2-manual","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/wall-reader-bus-doorlock-wa7-v2-manual\/","title":{"rendered":"Wall reader (bus) DoorLock-WA7-V2 &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/dehttps:\/\/docs.kentix.com\/de\/knowledge-base\/doorlock-wa7-v2-datenblatt\/\" target=\"_blank\" rel=\"noreferrer noopener\">Datasheet KXC-WA7-IPx-V2<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix IP wall readers enable contactless control of doors with a MIFARE\u00ae DESFire\u00ae RFID chip. The wall reader is suitable for installation in intercom systems or behind front panels. The reader&#8217;s electronics are housed in a 23 mm high casing. The setup always consists of the actual wall reader and the connected Kentix <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager<\/a>. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes\/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">For the operation of the wall readers (version: V2), a Kentix AccessManager for cable readers (KXP-2-RS) with a KentixONE software version of 8.2.0 or higher is required. Information about the relay and<strong> circuit diagrams including examples<\/strong> can be found here:&nbsp;<a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager (Bus)<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001.png\" alt=\"\" class=\"wp-image-9914\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-c3c07582-9e2e-4ace-91a8-a7c32383132f\"><ol class=\"fa-ul\"><li>Connection terminal<\/li><li>DIP switch<\/li><\/ol><style>#heroic-styled-list-c3c07582-9e2e-4ace-91a8-a7c32383132f li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Connection terminal<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Terminal #<br\/>Reader<\/th><th class=\"has-text-align-center\" data-align=\"center\">Function<br\/>Reader<\/th><th class=\"has-text-align-center\" data-align=\"center\">Terminal #<br\/>AccessManager<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS-485 A<\/td><td class=\"has-text-align-center\" data-align=\"center\">6 (BUS A)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS-485 B<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 (BUS B)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><td class=\"has-text-align-center\" data-align=\"center\">12 &#8211; 30 VDC (+)<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 (+)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><td class=\"has-text-align-center\" data-align=\"center\">GND (-)<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 (-)<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA7-IPx-V2 Connection terminal<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">DIP switch<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">DIP<\/th><th class=\"has-text-align-center\" data-align=\"center\">Function<\/th><th class=\"has-text-align-center\" data-align=\"center\">Standard<br\/>settings<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><td class=\"has-text-align-center\" data-align=\"center\">RS-485 BIAS ON\/OFF<\/td><td class=\"has-text-align-center\" data-align=\"center\">OFF<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><td class=\"has-text-align-center\" data-align=\"center\">Termination 120 Ohm<br\/>(terminating resistor)<\/td><td class=\"has-text-align-center\" data-align=\"center\">OFF<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA7-IPx-V2 DIP switch<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\"><strong>Important!  <\/strong>Wall readers of different versions (V1, V2 ) cannot be operated on one AccessManager. The version identifier (e.g. V2) is coded in the article number.<br><strong>For the operation of the wall readers with version 2 (V2), the connected AccessManagers requires at least the KentixONE version 8.2.0<\/strong><\/p>\n\n<h3 class=\"wp-block-heading\">Dimensions<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"673\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-1024x673.png\" alt=\"\" class=\"wp-image-9912\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-1024x673.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-400x263.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-150x99.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-768x505.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-50x33.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-1536x1009.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-2048x1345.png 2048w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-60x39.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7_Abmessungen-100x66.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h3 class=\"wp-block-heading\">Connection example<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002.png\" alt=\"\" class=\"wp-image-9916\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.002-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">The connection example schematically shows the wiring of two DoorLock-WA7 with door contacts and external electric strikes to an AccessManager.<\/p>\n\n<p class=\"wp-block-paragraph\">Terminal 2 on the AccessManager provides communication via the data bus and the supply of operating voltage for the wall readers. (terminals 3-6). Terminal 2 serves as a common potential for the power supply of door openers with the PoE supply voltage of the AccessManager.<\/p>\n\n<p class=\"wp-block-paragraph\">Terminal 1 is used for connection of potential-free contacts (&#8220;door contacts&#8221;, terminals 1-4) and switching of door openers by relay 2 (5-6) and relay 1 (7-8). Relay 1 and 2 switch terminal 1 to terminal 2 to common potential (terminal2, terminal 2).<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Commissioning two wall readers on one AccessManager<\/strong><br>If two wall readers are to be operated with one AccessManager, proceed as follows for commissioning:<br>Connect the first wall reader to the AccessManager. Add it in the main device with &#8220;DoorLock (IP)&#8221;. Once the first WallReader has been successfully added, disconnect it temporarily from the AccessManager to connect the second WallReader and add it as well. Once both devices have been successfully registered, reconnect the first WallReader to the AccessManager and then put both devices into operation together. <\/p>\n\n<h3 class=\"wp-block-heading\">Installation example<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003.png\" alt=\"\" class=\"wp-image-9933\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7.003-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-2aadd894-6eee-4c7b-bb62-76da87242721\"><ol class=\"fa-ul\"><li>Front panel (maximum thickness 5mm)<\/li><li>DoorLock-WA7<\/li><\/ol><style>#heroic-styled-list-2aadd894-6eee-4c7b-bb62-76da87242721 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">The DoorLock-WA7 can be mounted in intercom systems or behind front panels using the adhesive pads supplied. The reading range of the DoorLock depends on the material of the front panel and other environmental influences. The material thickness of the front panel must not exceed 5 mm.<\/p>\n\n<h2 class=\"wp-block-heading\">Signaling<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Function<\/strong><\/td><td><strong>Signal and explanation<\/strong><\/td><\/tr><tr><td>Wall reader is offline<\/td><td>LED flashes magenta<\/td><\/tr><tr><td>Access granted<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Door is opened by time profiles<\/td><td>LED lights up permanently green<\/td><\/tr><tr><td>Access denied<\/td><td>short tone, LED flashes red<\/td><\/tr><tr><td>Zone is armed<\/td><td>3 long tones, simultaneously LED flashes 3x red<\/td><\/tr><tr><td>Arming not possible<\/td><td>long tone, LED flashes red<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table signaling<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Datasheet KXC-WA7-IPx-V2 Overview Kentix IP wall readers enable contactless control of doors with a MIFARE\u00ae DESFire\u00ae RFID chip. The wall reader is suitable for installation in intercom systems or behind front panels. The reader&#8217;s electronics are housed in a 23 mm high casing. The setup always consists of the actual&#8230;<\/p>\n","protected":false},"author":6,"featured_media":9921,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[157],"ht-kb-tag":[],"class_list":["post-9923","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-en"],"custom_fields":{"kentix_order_code":["KXC-WA7-IP1-V2, KXC-WA7-IP2-V2"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartaccess-bus-en","name":"SmartAccess Bus","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/06\/KXC-WA7-150x100.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/9923","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=9923"}],"version-history":[{"count":5,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/9923\/revisions"}],"predecessor-version":[{"id":12258,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/9923\/revisions\/12258"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/9921"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=9923"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=9923"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=9923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}