{"id":9373,"date":"2024-02-29T14:19:32","date_gmt":"2024-02-29T13:19:32","guid":{"rendered":"https:\/\/docs.kentix.com\/?post_type=ht_kb&#038;p=9373"},"modified":"2026-11-19T14:44:50","modified_gmt":"2026-11-19T13:44:50","slug":"smartpdu-40u-3x16-32a-datasheet","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/smartpdu-40u-3x16-32a-datasheet\/","title":{"rendered":"SmartPDU 40HE, 3\u00d763A (43 kVA) &#8211; DATA SHEET"},"content":{"rendered":"\n<figure class=\"wp-block-table is-style-regular\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Type<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-xx-xx-0036-3-63-V<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Rated power, voltage<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">43 kVA, 400\/230 V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Connector plug<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">CEE plug<strong>(RED<\/strong>) to IEC60309, 5-pin, 63A\/230\/400V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Connection cable<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Length 3m, rubber hose cable H07RN-F-5G16<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Number of Outlets Cx (IEC 60320)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">36<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Locking sockets<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">IEC-LOCK for Cx<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Fuse-circuit breaker with hinged cover<br\/><\/strong>(rated current, characteristics, short-circuit current<strong>)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">12x 16A C-type, 6kA<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Current measurement (calibrated)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Integrated, calibrated current measurement, accuracy Class B (MID, EN 50470-3)<br\/>Minimum current: 250 mA, maximum current: 63 A<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Residual current measurement (RCM)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Integrated AC\/DC sensitive residual current measurement according to IEC 60664-1<br\/>\u00b1300mA\/100mA (RMS), accuracy &lt;0.2mA<br\/>Frequency range DC 0..2kHz<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Connectivity<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Ethernet (10\/100MBit), PoE Class 3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Kentix system socket<\/strong> <strong>(type B)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">RJ45 with Kentix specific pinout for system expansion<br\/>1 x System Port (BUS) Type B<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Communication and security<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">HTTPS (certificate), integrated web server, ReSt API<br\/>Protocols: SNMP V2\/3 (GET, TRAP), NTP, SMTP, DHCP, DNS, MODBUS-TCP<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Management<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Main satellite management via KentixONE<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Measurement\/communication objects<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Voltage (V) L1\/L2\/L3\/Total<br\/>Current (A) L1\/L2\/L3\/Total<br\/>Consumption (kWh) L1\/L2\/L3\/Total<br\/>Active power (W) L1\/L2L3\/total<br\/>Apparent power (VA) L1\/L2\/L3\/total<br\/>Reactive power (VAR) L1\/L2\/L3\/Total<br\/>Effective factor (cos phi)<br\/>Frequency (Hz)<br\/>Phase monitoring L1\/L2\/L3<br\/>Differential current AC (optional)<br\/>Differential current DC (optional)<br\/>Fuse status L1.1+L1.2\/L1.3+L1.4\/L2.1+L2.2\/L2.3+L2.4\/L3.1+L3.2\/L3.3+L3.4<br\/>Temperature (\u00b0C)<br\/>Relative humidity (%)<br\/>Dew point (\u00b0C)<br\/>Vibration (G)<br\/>Air quality VOC (AIQ index)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Display (LCD)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Illuminated LCD display (power, current, voltage, consumption)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Optical signaling<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">LED with RED\/GREEN (operation, alarm\/error status)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Acoustic signaling<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Signal generator with 80dB, 2.3kHz (alarm\/fault conditions)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Factory state<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Button for factory reset<br\/><strong>(default IP: 192.168.100.226<\/strong>)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Power dissipation<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">approx. 100W (full load)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Housing<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Sheet metal, powder coated RAL9005, protection class 1, protection class IP20, mounting bracket can be mounted at a distance of 5U<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"1\"><strong>Size<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">1770 x 78.2 x 62.5 mm (HxWxD)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Weight<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">approx. 13,5kg<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Environmental conditions<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">0\u00b0C to 60\u00b0C, humidity 5-95%, storage temperature: -20\u00b0C to 60\u00b0C<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Certification<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">CE (2014\/30\/EC, 2014\/35\/EC, 2011\/65\/EU)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Electrical safety<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">DGUV-V3 testing, VDE 0105-100<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Marking<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">Serial number (barcode), additional free<br\/>Marking area front panel (60x30mm)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Scope of delivery<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">SmartPDU with connection cable 3m and plug, mounting material: 3 90\u00b0 angle brackets,<br\/>12 pcs. countersunk head screws M3x15 with hexagon socket 2mm, front foils A\/B (ORANGE), test report    <\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Type KPMDU-RC-xx-xx-0036-3-63-V Rated power, voltage 43 kVA, 400\/230 V Connector plug CEE plug(RED) to IEC60309, 5-pin, 63A\/230\/400V Connection cable Length 3m, rubber hose cable H07RN-F-5G16 Number of Outlets Cx (IEC 60320) 36 Locking sockets IEC-LOCK for Cx Fuse-circuit breaker with hinged cover(rated current, characteristics, short-circuit current) 12x 16A C-type, 6kA&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"ht-kb-category":[94,96],"ht-kb-tag":[],"class_list":["post-9373","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-data-sheets-en","ht_kb_category-data-sheets-en-3"],"custom_fields":{"kentix_order_code":["KPMDU-xx-xx-xx-0036-3-63-V"]},"categories":[{"slug":"data-sheets-en","name":"Datasheets","shortName":""},{"slug":"data-sheets-en-3","name":"Datasheets","shortName":""}],"featured_media_url":null,"_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/9373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=9373"}],"version-history":[{"count":30,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/9373\/revisions"}],"predecessor-version":[{"id":14651,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/9373\/revisions\/14651"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=9373"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=9373"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=9373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}