{"id":5096,"date":"2023-04-25T16:29:34","date_gmt":"2023-04-25T14:29:34","guid":{"rendered":"https:\/\/docs.kentix.com\/knowledge-base\/wall-reader-doorlock-kxc-wa3-ipx-v2\/"},"modified":"2025-11-14T09:51:25","modified_gmt":"2025-11-14T08:51:25","slug":"wall-reader-doorlock-kxc-wa3-ipx-v2","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/wall-reader-doorlock-kxc-wa3-ipx-v2\/","title":{"rendered":"Wall reader (bus) DoorLock-WA3-V2 &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/?post_type=ht_kb&amp;p=2335\" target=\"_blank\" rel=\"noreferrer noopener\">DATA SHEET KXC-WA3-IPx-V2<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix IP wall readers enable contactless control of doors with a MIFARE\u00ae DESFire\u00ae RFID chip. The setup always consists of the actual wall reader and the connected Kentix <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager<\/a>. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes\/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">For the operation of the wall readers (version: V2), a Kentix AccessManager for cable readers (KXP-2-RS) with a KentixONE software version of 8.2.0 or higher is required. Information about the relay and<strong> circuit diagrams including examples<\/strong> can be found here:&nbsp;<a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager (Bus)<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">System topology<\/h2>\n\n<p class=\"wp-block-paragraph\">An illustration of the SmartAccess system topology can be found <a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/how-is-a-smartaccess-system-topology-structured\/\" target=\"_blank\">here<\/a>.<\/p>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h3 class=\"wp-block-heading\">DoorLock-WA3-V2 Front view<\/h3>\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001.png\" alt=\"\" class=\"wp-image-10043\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-06b527c7-46fb-4230-9621-5a7bcbe62a16\"><ol class=\"fa-ul\"><li>Touch keyboard with illuminated keypad and &#8220;arm alarm&#8221; function key<\/li><li>Touch keyboard with illuminated keypad and &#8220;disarm alarm&#8221; function key<\/li><li>Integrated RFID reader, the entire surface serves as a reading surface.<\/li><\/ol><style>#heroic-styled-list-06b527c7-46fb-4230-9621-5a7bcbe62a16 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">The keypad can be deactivated in the configuration screen of the wall reader (from KentixONE version 8.4.3). This can be useful if an alarm group is only to be armed or disarmed on a specific wall reader using an RFID token. <\/p>\n\n<h3 class=\"wp-block-heading\">DoorLock-WA3-V2 Rear view<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002.png\" alt=\"\" class=\"wp-image-10046\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-V2.002-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-9634fdf7-18f8-4843-ad21-ae94fc1b318e\"><ol class=\"fa-ul\"><li>Connection terminals, assignment see table<\/li><\/ol><style>#heroic-styled-list-9634fdf7-18f8-4843-ad21-ae94fc1b318e li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Terminal assignment wall reader WA3-V2<\/h3>\n\n<p class=\"wp-block-paragraph\">Telecommunication cable type: I-J(ST)Y 2x2x0.<sup>8mm2<\/sup> is suitable for connection.<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Terminal #<br\/>Reader<\/th><th>Function<br\/>Reader<\/th><th class=\"has-text-align-center\" data-align=\"center\">Terminal #<br\/>AccessManager<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td>12-30VDC (+)<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 (+)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td>GND (-)<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 (-)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td>RS-485 A<\/td><td class=\"has-text-align-center\" data-align=\"center\">6 (BUS A)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><td>RS-485 B<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 (BUS B)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><td>&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><td>&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><td>&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><td>&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">9<\/td><td>&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">10<\/td><td>&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA3-IPx-V2 Terminal block<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\"><strong>Important!<\/strong>  Wall readers of different versions cannot be operated on one AccessManager. The version identifier (e.g. V2) is coded in the article number.<\/p>\n\n<h2 class=\"wp-block-heading\">Connection example<\/h2>\n\n<p class=\"wp-block-paragraph\">Two wall readers with door contacts and external door openers<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001.jpeg\" alt=\"\" class=\"wp-image-5595\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA3-IPX-V2.001-100x75.jpeg 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\">Terminal block 2 on the AccessManager (bus) is used for communication (terminals 5 and 6) and for supplying power (terminals 3 and 4) to the wall readers.<br\/><br\/>Terminal block 1 on the AccessManager (bus) contains two digital inputs (potential-free) and two relay contacts (changeover contacts). The digital inputs (terminals 1 and 2, terminals 3 and 4) are used to monitor the status of the doors (door contact). The relay contacts (terminals 5 and 6, terminals 7 and 8) can be used to control door openers. A jumper can be used to switch between normally closed and normally open contacts.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Commissioning two wall readers on one AccessManager<\/strong><br>If two wall readers are to be operated with one AccessManager, proceed as follows for commissioning:<br>Connect the first wall reader to the AccessManager. Add it in the main device with &#8220;DoorLock (IP)&#8221;. Once the first WallReader has been successfully added, disconnect it temporarily from the AccessManager to connect the second WallReader and add it as well. Once both devices have been successfully registered, reconnect the first WallReader to the AccessManager and then put both devices into operation together. <\/p>\n\n<h2 class=\"wp-block-heading\">User and access management<\/h2>\n\n<p class=\"wp-block-paragraph\">The administration of users and access rights is done on the main device of the installation with KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software is available in the <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a> section.<\/p>\n\n<h2 class=\"wp-block-heading\">Signaling<\/h2>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td><strong>Signal and explanation<\/strong><\/td><\/tr><tr><td>Wall reader is offline<\/td><td>LED flashes magenta<\/td><\/tr><tr><td>Pine input <\/td><td>LED flashes blue<\/td><\/tr><tr><td>Access granted<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Door is opened by time profiles<\/td><td>LED lights up permanently green<\/td><\/tr><tr><td>Access denied<\/td><td>short tone, LED flashes red<\/td><\/tr><tr><td>Zone is armed<\/td><td>3 long tones, simultaneously LED flashes 3x red<\/td><\/tr><tr><td>Arming not possible<\/td><td>long tone, LED flashes red<\/td><\/tr><tr><td>Zone is armed<\/td><td>Kentix logo flashes white<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table signaling<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>DATA SHEET KXC-WA3-IPx-V2 Overview Controls DoorLock-WA3-V2 Front view DoorLock-WA3-V2 Rear view Terminal assignment wall reader WA3-V2 Telecommunication cable type: I-J(ST)Y 2x2x0.8mm2 is suitable for connection. Terminal #Reader FunctionReader Terminal #AccessManager 1 12-30VDC (+) 3 (+) 2 GND (-) 4 (-) 3 RS-485 A 6 (BUS A) 4 RS-485 B 5&#8230;<\/p>\n","protected":false},"author":4,"featured_media":5093,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[157],"ht-kb-tag":[],"class_list":["post-5096","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-en"],"custom_fields":{"kentix_order_code":["KXC-WA3-IP1-V2, KXC-WA3-IP2-V2","KXC-WA3-IP1-V2, KXC-WA3-IP2-V2","KXC-WA3-IP1-V2, KXC-WA3-IP2-V2","KXC-WA3-IP1-V2, KXC-WA3-IP2-V2"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartaccess-bus-en","name":"SmartAccess Bus","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/04\/KXC-WA3-IP2-front-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/5096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=5096"}],"version-history":[{"count":18,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/5096\/revisions"}],"predecessor-version":[{"id":12260,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/5096\/revisions\/12260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/5093"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=5096"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=5096"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=5096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}