{"id":4158,"date":"2023-02-24T16:28:05","date_gmt":"2023-02-24T15:28:05","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/doorlock-ra4-operating-instructions\/"},"modified":"2023-12-21T11:17:09","modified_gmt":"2023-12-21T10:17:09","slug":"doorlock-ra4-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-ra4-operating-instructions\/","title":{"rendered":"Rack lock (bus) DoorLock-RA4 &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-ra4-art-kxc-ra4-ip2-x-data-sheet\/\" target=\"_blank\" rel=\"noreferrer noopener\">DATASHEET KXC-RA4<\/a><\/pre>\n\n\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The DoorLock-RA4 is a wired locking solution for IT racks and distribution cabinets. The DoorLock offers the possibility of two-factor authentication via a touch PIN keypad and an RFID reader. In addition, the position of the lever on the DoorLock is sensed via an integrated magnetic contact.<br><br>The DoorLock requires a suitable remote station for operation. This remote station is formed by the network-capable devices AccessManager (SmartRelay) or SmartPDU, which act as both bus gateway and power supply.<br><br>For central management, an AccessManager, SiteManager or AlarmManager is required in the MAIN-DEVICE operating mode. Teach-in and configuration are performed entirely via the KentixONE web interface. The maximum cable length between gateway and DoorLock is limited to 100m. Up to 16 DoorLocks can be taught-in to one AccessManager (SmartRelay). With a SmartPDU as gateway, the number is limited to 2 DoorLocks.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Connection and operating elements<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front.png\" alt=\"\" class=\"wp-image-7038\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e9d3f247-714f-4264-84af-1544bbe110fd\"><ol class=\"fa-ul\"><li>Status LED (RED, GREEN)<\/li><li>RFID reader unit (Mifare\u00ae, Mifare\u00aeDESFire\u00ae)<\/li><li>Touch PIN Keyboard<\/li><\/ol><style>#heroic-styled-list-e9d3f247-714f-4264-84af-1544bbe110fd li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn.png\" alt=\"\" class=\"wp-image-7218\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-1533134a-40a0-4e4d-90a1-ec3a3ba64efa\"><ol class=\"fa-ul\"><li>Teach In Code<\/li><\/ol><style>#heroic-styled-list-1533134a-40a0-4e4d-90a1-ec3a3ba64efa li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The Teach In Code is required to teach in the DoorLock. The 10-digit code is located both on the side and on the back of the DoorLock.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1.png\" alt=\"\" class=\"wp-image-7220\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-5cf5e572-95d0-450e-a7c8-13be22bd2118\"><ol class=\"fa-ul\"><li>Serial number<\/li><li>Teach In Code<\/li><li>Square mandrel 8 mm<\/li><li>Connection socket<\/li><\/ol><style>#heroic-styled-list-5cf5e572-95d0-450e-a7c8-13be22bd2118 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">System topology<\/h2>\n\n<p class=\"wp-block-paragraph\">An illustration of the SmartAccess system topology can be found <a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/how-is-a-smartaccess-system-topology-structured\/\" target=\"_blank\">here<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Connection variant 1: To AccessManager SmartRelay<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The DoorLock-RA4 is connected to an AccessManager SmartRelay. By using the Kentix distributor box KXC-RA4-DB-BUS, up to 16 DoorLocks can be taught in at one AccessManager. Two DoorLocks and two door contacts can be connected to one distribution box.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78.png\" alt=\"\" class=\"wp-image-2217\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">DoorLock-RA4 to AccessManager SmartRelay<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-a6751672-0c4a-4993-919b-6ccb0811b5ec\"><ol class=\"fa-ul\"><li>Ethernet port with PoE power supply, Class 3 (12.95W)<\/li><li>Distributor box KXC-RA4-DB-BUS<\/li><li>DoorLock KXC-RA4<\/li><li>Door contact KDC1-W<\/li><\/ol><style>#heroic-styled-list-a6751672-0c4a-4993-919b-6ccb0811b5ec li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">The KXP-2-RS-ADP adapter is required to connect a rack lever or distribution box to terminal block 2 of the access manager. This is included in every DoorLock-RA4 basic package.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Connection variant 2: To Kentix SmartPDU<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Kentix DoorLock-RA4 is connected to the system port of the SmartPDU. With one distributor box, a maximum of 2 DoorLocks and two door contacts can be connected per SmartPDU.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">User and access management<\/h2>\n\n<p class=\"wp-block-paragraph\">The administration of users and access rights is done on the main device of the installation with KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software is available in the <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a> section.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dimensions<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"962\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-1024x962.png\" alt=\"\" class=\"wp-image-2230\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-1024x962.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-400x376.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-150x141.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-768x722.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-50x47.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-60x56.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-100x94.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84.png 1228w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Installation<\/h2>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">Install only when open!<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hole pattern for mounting<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"LochbildRA4\">The following hole pattern is required for mounting the DoorLock-RA4. The bar lock of the cabinet door must have a receptacle for an 8 mm square mandrel.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"115\" height=\"400\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-115x400.png\" alt=\"\" class=\"wp-image-2232\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-115x400.png 115w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-294x1024.png 294w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-43x150.png 43w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-14x50.png 14w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-17x60.png 17w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-29x100.png 29w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85.png 335w\" sizes=\"auto, (max-width: 115px) 100vw, 115px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"926\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-1024x926.png\" alt=\"\" class=\"wp-image-2234\" style=\"width:477px;height:431px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-1024x926.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-400x362.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-150x136.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-768x694.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-50x45.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-60x54.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-100x90.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86.png 1176w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8316a505-7c6a-440e-a21e-224766462118\"><ol class=\"fa-ul\"><li>Phillips screw for upper attachment of the DoorLock to the cabinet door<\/li><li>Spacer washer for thin cabinet doors<\/li><li>Locking tooth screw with hexagonal head for fastening the bar lock to the DoorLock<\/li><li>Phillips screws for lower attachment of the DoorLock to the cabinet door<\/li><\/ol><style>#heroic-styled-list-8316a505-7c6a-440e-a21e-224766462118 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Ordering information<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The DoorLock-RA4 is available with two directions of rotation of the square mandrel. With the DoorLock with the order number KXC-RA4-IPx-L, the square mandrel rotates counterclockwise \/ left-handed (viewing direction from inside on the mandrel) and with the order number KXC-RA4-IPx-R, the mandrel rotates clockwise \/ right-handed.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1.png\" alt=\"\" class=\"wp-image-7042\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Dorn-1-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">KXC-RA4-IPx-L<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-f5b561b2-4dbe-42fc-8f1a-9bd05fa0f308\"><ol class=\"fa-ul\"><li>Square spike<\/li><\/ol><style>#heroic-styled-list-f5b561b2-4dbe-42fc-8f1a-9bd05fa0f308 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Adapters are required for mounting the DoorLocks on cabinet doors with a different hole pattern.<\/p>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Signaling<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td><strong>Signal and explanation<\/strong><\/td><\/tr><tr><td>DoorLock not closed<\/td><td>LED lights up permanently red<\/td><\/tr><tr><td>Reed contact not closed<\/td><td>LED lights up permanently red<\/td><\/tr><tr><td>DoorLock and reed contact closed<\/td><td>LED lights up permanently green<\/td><\/tr><tr><td>Pine input<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Access granted<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Access denied<\/td><td>3 long tones, simultaneously LED flashes 3x red<\/td><\/tr><tr><td>Emergency access<\/td><td>No signaling<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table signaling<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Emergency opening<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If the power supply is lost, the <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=KXC-RA4-EMS\" target=\"_blank\" rel=\"noreferrer noopener\">KXC-RA4-EMS<\/a> emergency opening set can be used.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATASHEET KXC-RA4 Overview The DoorLock-RA4 is a wired locking solution for IT racks and distribution cabinets. The DoorLock offers the possibility of two-factor authentication via a touch PIN keypad and an RFID reader. In addition, the position of the lever on the DoorLock is sensed via an integrated magnetic contact&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":339,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[159],"ht-kb-tag":[],"class_list":["post-4158","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-for-it-racks"],"custom_fields":{"kentix_order_code":["KXC-RA4-IP1-R,KXC-RA4-IP1-L,KXC-RA4-IP2-R, KXC-RA4-IP2-L"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartaccess-bus-for-it-racks","name":"SmartAccess Bus for IT racks","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KXC-RA4-IPx-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4158","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4158"}],"version-history":[{"count":28,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4158\/revisions"}],"predecessor-version":[{"id":8507,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4158\/revisions\/8507"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/339"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4158"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4158"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}