{"id":4158,"date":"2023-02-24T16:28:05","date_gmt":"2023-02-24T15:28:05","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/doorlock-ra4-operating-instructions\/"},"modified":"2026-04-24T14:06:38","modified_gmt":"2026-04-24T12:06:38","slug":"doorlock-ra4-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-ra4-operating-instructions\/","title":{"rendered":"Rack lock (bus) DoorLock-RA4 &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-ra4-art-kxc-ra4-ip2-x-data-sheet\/\" target=\"_blank\" rel=\"noreferrer noopener\">DATASHEET KXC-RA4<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">The DoorLock-RA4 is a wired locking solution for IT racks and distribution cabinets. The DoorLock offers the possibility of two-factor authentication via a touch PIN keypad and an RFID reader. In addition, the position of the lever on the DoorLock is sensed via an integrated magnetic contact.<br\/><br\/>The DoorLock requires a suitable remote station for operation. This remote station is formed by the network-capable devices AccessManager (SmartRelay) or SmartPDU, which act as both bus gateway and power supply.<br\/><br\/>For central management, an AccessManager, SiteManager or AlarmManager is required in the MAIN-DEVICE operating mode. Teach-in and configuration are performed entirely via the KentixONE web interface. The maximum cable length between gateway and DoorLock is limited to 100m. Up to 16 DoorLocks can be taught-in to one AccessManager (SmartRelay). With a SmartPDU as gateway, the number is limited to 2 DoorLocks.<\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Connection and operating elements<\/h2>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front.png\" alt=\"\" class=\"wp-image-7038\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_front-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-aee14675-629d-47c1-b3be-bed711e7f54c\"><ol class=\"fa-ul\"><li>Status LED (RED, GREEN)<\/li><li>RFID reader unit (Mifare\u00ae, Mifare\u00aeDESFire\u00ae)<\/li><li>Touch PIN Keyboard<\/li><\/ol><style>#heroic-styled-list-aee14675-629d-47c1-b3be-bed711e7f54c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">The keypad can be deactivated in the configuration screen of the rack lock (from KentixONE version 8.4.3). This can be useful if access to certain rack locks should only be possible via RFID token. <\/p>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn.png\" alt=\"\" class=\"wp-image-7218\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_TeachIn-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-df586f65-8d6c-4082-afa3-98e313feffa3\"><ol class=\"fa-ul\"><li>Teach In Code<\/li><\/ol><style>#heroic-styled-list-df586f65-8d6c-4082-afa3-98e313feffa3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">The Teach In Code is required to teach in the DoorLock. The 10-digit code is located both on the side and on the back of the DoorLock.<\/p>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1.png\" alt=\"\" class=\"wp-image-7220\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/09\/KXC-RA4_Seriennummer-1-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-9d52f8a2-3f33-483a-9967-4624a7354005\"><ol class=\"fa-ul\"><li>Serial number<\/li><li>Teach In Code<\/li><li>Square mandrel 8 mm<\/li><li>Connection socket<\/li><\/ol><style>#heroic-styled-list-9d52f8a2-3f33-483a-9967-4624a7354005 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h2 class=\"wp-block-heading\">System topology<\/h2>\n\n<p class=\"wp-block-paragraph\">An illustration of the SmartAccess system topology can be found <a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/how-is-a-smartaccess-system-topology-structured\/\" target=\"_blank\">here<\/a>.<\/p>\n\n<h3 class=\"wp-block-heading\">Connection variant 1: To AccessManager SmartRelay<\/h3>\n\n<p class=\"wp-block-paragraph\">The DoorLock-RA4 is connected to an AccessManager SmartRelay. By using the Kentix distributor box KXC-RA4-DB-BUS, up to 16 DoorLocks can be taught in at one AccessManager. Two DoorLocks and two door contacts can be connected to one distribution box.<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78.png\" alt=\"\" class=\"wp-image-2217\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-78-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">DoorLock-RA4 to AccessManager SmartRelay<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-71e38335-0b68-4920-920a-5179ddbbf9b4\"><ol class=\"fa-ul\"><li>Ethernet port with PoE power supply, Class 3 (12.95W)<\/li><li>Distributor box KXC-RA4-DB-BUS<\/li><li>DoorLock KXC-RA4<\/li><li>Door contact KDC1-W<\/li><\/ol><style>#heroic-styled-list-71e38335-0b68-4920-920a-5179ddbbf9b4 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">The KXP-2-RS-ADP adapter is required to connect a rack lever or distribution box to terminal block 2 of the access manager. This is included in every DoorLock-RA4 basic package.<\/p>\n\n<h3 class=\"wp-block-heading\">Connection variant 2: To Kentix SmartPDU<\/h3>\n\n<p class=\"wp-block-paragraph\">The Kentix DoorLock-RA4 is connected to the system port of the SmartPDU. With one distributor box, a maximum of 2 DoorLocks and two door contacts can be connected per SmartPDU.<\/p>\n\n<h2 class=\"wp-block-heading\">User and access management<\/h2>\n\n<p class=\"wp-block-paragraph\">The administration of users and access rights is done on the main device of the installation with KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software is available in the <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a> section.<\/p>\n\n<h2 class=\"wp-block-heading\">Dimensions<\/h2>\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"962\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-1024x962.png\" alt=\"\" class=\"wp-image-2230\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-1024x962.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-400x376.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-150x141.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-768x722.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-50x47.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-60x56.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84-100x94.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-84.png 1228w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h2 class=\"wp-block-heading\">Installation<\/h2>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">First connect the DoorLock with the Slimline patch cable before attaching it to the rack. Only install the DoorLock when it is open! <\/p>\n\n<h3 class=\"wp-block-heading\">Hole pattern for mounting<\/h3>\n\n<p class=\"wp-block-paragraph\" id=\"LochbildRA4\">The following hole pattern is required for mounting the DoorLock-RA4. The bar lock of the cabinet door must have a receptacle for an 8 mm square mandrel.<\/p>\n\n<figure class=\"wp-block-image aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"115\" height=\"400\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-115x400.png\" alt=\"\" class=\"wp-image-2232\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-115x400.png 115w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-294x1024.png 294w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-43x150.png 43w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-14x50.png 14w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-17x60.png 17w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85-29x100.png 29w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-85.png 335w\" sizes=\"auto, (max-width: 115px) 100vw, 115px\" \/><\/figure>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"926\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-1024x926.png\" alt=\"\" class=\"wp-image-2234\" style=\"width:477px;height:431px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-1024x926.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-400x362.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-150x136.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-768x694.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-50x45.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-60x54.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86-100x90.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-86.png 1176w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-b6ec251c-e881-4f17-bed5-e41cc395ba6d\"><ol class=\"fa-ul\"><li>Cross-head screw for fixing the top of the DoorLock to the cabinet door (tightening torque 1.5 Nm)<\/li><li>Spacer washer for thin cabinet doors<\/li><li>Locking screw with hexagon head for fastening the rod lock to the DoorLock (tightening torque 1.5 Nm)<\/li><li>Cross-head screws for fixing the bottom of the DoorLock to the cabinet door (tightening torque 1.5 Nm)<\/li><\/ol><style>#heroic-styled-list-b6ec251c-e881-4f17-bed5-e41cc395ba6d li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Ordering information<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The DoorLock-RA4 is available in two directions of rotation of the square spindle (right\/left). As the lifting handle always performs the same movement, the gear or the shaft rotation must be set according to the L\/R door side. <\/p>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Please note the required direction of rotation of the axle when ordering.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The direction of rotation can always be seen from the rear of the door or lever.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001.png\" alt=\"\" class=\"wp-image-10023\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/KXC-RA4-Bestellhilfe.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-5abfd6b6-acf3-45ec-ad5a-fb773f2b5f75\"><ol class=\"fa-ul\"><li>DoorLock-RA4-IP2-L<\/li><li>DoorLock-RA4-IP2-R<\/li><\/ol><style>#heroic-styled-list-5abfd6b6-acf3-45ec-ad5a-fb773f2b5f75 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Adapters are required for mounting the DoorLocks on cabinet doors with a different hole pattern.<\/p>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Signaling<\/h2>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td><strong>Signal and explanation<\/strong><\/td><\/tr><tr><td>DoorLock not closed<\/td><td>LED lights up permanently red<\/td><\/tr><tr><td>Reed contact not closed<\/td><td>LED lights up permanently red<\/td><\/tr><tr><td>DoorLock and reed contact closed<\/td><td>LED lights up permanently green<\/td><\/tr><tr><td>Pin input<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Access granted<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Access denied<\/td><td>3 long tones, simultaneously LED flashes 3x red<\/td><\/tr><tr><td>Emergency access<\/td><td>No signaling<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table signaling<\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Emergency opening<\/h2>\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/kentix.com\/de-de\/notoeffnungsset-fuer-mechn.-notoeffnung-kxc-ra4-rackhebel\/kxc-ra4-ems\" target=\"_blank\" rel=\"noreferrer noopener\">DoorLock-RA4-EMS<\/a> is an emergency opening set for mechanical emergency opening of the DoorLock-RA4. In the event of an interruption in the power supply or a defect, the DoorLock can be opened mechanically using the tool included in the set. The set includes the emergency opening tool and 2 front foils.<\/p>\n\n<h4 class=\"wp-block-heading\">Designation of the elements<\/h4>\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"11137\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001.png\" alt=\"\" class=\"wp-image-11137\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KXC-RA4-EMS.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-4a579aff-6968-4f14-8c17-70c3be11e61f\"><ol class=\"fa-ul\"><li>KXC-RA4<\/li><li>Emergency opening tool<\/li><\/ol><style>#heroic-styled-list-4a579aff-6968-4f14-8c17-70c3be11e61f li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h4 class=\"wp-block-heading\">Steps for emergency opening<\/h4>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e25f6d4a-83e1-4733-bf2a-d4c0e2ea0176\"><ol class=\"fa-ul\"><li>Remove the front foil of the DoorLock-RA4<\/li><li>Insert the emergency opening tool into the recess<\/li><li>Rack lock pops open<\/li><li>Pull out the emergency opening tool<\/li><li>Stick on new front foil<\/li><\/ol><style>#heroic-styled-list-e25f6d4a-83e1-4733-bf2a-d4c0e2ea0176 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">When inserting the emergency opening tool into the rack lock, ensure that it is correctly aligned.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">From series 16, the front foil no longer needs to be removed before the emergency opening tool can be inserted.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATASHEET KXC-RA4 Overview The DoorLock-RA4 is a wired locking solution for IT racks and distribution cabinets. The DoorLock offers the possibility of two-factor authentication via a touch PIN keypad and an RFID reader. In addition, the position of the lever on the DoorLock is sensed via an integrated magnetic contact&#8230;.<\/p>\n","protected":false},"author":4,"featured_media":339,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[159],"ht-kb-tag":[],"class_list":["post-4158","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-for-it-racks"],"custom_fields":{"kentix_order_code":["KXC-RA4-IP1-R,KXC-RA4-IP1-L,KXC-RA4-IP2-R, KXC-RA4-IP2-L"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartaccess-bus-for-it-racks","name":"SmartAccess Bus for IT racks","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KXC-RA4-IPx-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4158","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4158"}],"version-history":[{"count":30,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4158\/revisions"}],"predecessor-version":[{"id":13735,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4158\/revisions\/13735"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/339"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4158"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4158"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}