{"id":4150,"date":"2023-02-14T14:36:44","date_gmt":"2023-02-14T13:36:44","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/multisensor-lan-ethernet-operating-instructions\/"},"modified":"2026-01-16T08:29:27","modified_gmt":"2026-01-16T07:29:27","slug":"multisensor-lan-ethernet-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/multisensor-lan-ethernet-operating-instructions\/","title":{"rendered":"MultiSensor-LAN (Ethernet) &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/multisensor-lan-art-kms-lan-b-w-kms-lan-rf-b-w-data-sheet\/\" target=\"_blank\" rel=\"noreferrer noopener\">DATA SHEET MULTISENSOR-LAN<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">KentixONE Operating mode<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">SiteManager Operation<\/th><th class=\"has-text-align-center\" data-align=\"center\">Stand-alone operation<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/docs.kentix.com\/en\/?post_type=ht_kb&amp;p=6835\">Further information on the operating mode<\/a><\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">The MultiSensor-LAN integrates a large number of individual sensors in one compact device and monitors their measured values. The MultiSensor-LAN is optimized for monitoring closed rooms and is typically mounted on or near the ceiling. The MultiSensor-LAN is network-compatible and is supplied with power via Power over Ethernet (PoE).<\/p>\n\n<p class=\"wp-block-paragraph\">The MultiSensor-LAN can be operated as a stand-alone device (operating mode: Stand-Alone Device) or in a network (operating mode: Satellite Device) with other MultiSensor-LAN and other Kentix devices. The KentixONE software is already integrated via the integrated web server (HTTPS). Configuration is carried out via a web browser and, depending on the operating mode, locally on the MultiSensor-LAN itself (operating mode: Stand-Alone Device) or on a central instance such as the SiteManager or AlarmManager (operating mode: Satellite Device).<\/p>\n\n<p class=\"wp-block-paragraph\">In addition to the Ethernet network interface, the MultiSensor-LAN has a BLE radio interface (2.4 GHz). Additional Kentix wireless sensors can be connected via these in the Satellite Device operating mode. The MultiSensor-LAN then also works as an Ethernet wireless gateway, making it very easy to set up stable sensor networks. The wireless sensors can be distributed within a radius of up to 20m, depending on the structure of the building.<\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h3 class=\"wp-block-heading\">Front<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front.jpeg\" alt=\"\" class=\"wp-image-3668\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/kms-lan_front-100x75.jpeg 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-dcab0467-9ec1-4b54-89d0-7944733d50e6\"><ol class=\"fa-ul\"><li>Status LED : <br><strong>GREEN: <\/strong>POWER OK, no alarms pending<br> RED<strong>: <\/strong>POWER OK, alarms pending<\/li><li>360\u00b0 PIR motion sensor<\/li><\/ol><style>#heroic-styled-list-dcab0467-9ec1-4b54-89d0-7944733d50e6 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Back<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-1024x768.png\" alt=\"\" class=\"wp-image-1752\" style=\"width:604px;height:453px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-28.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">MultiSensor LAN Rear view<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-4990a502-00ab-42b6-ba33-52c7e0bc7aa2\"><ol class=\"fa-ul\"><li>Reset button<\/li><li>Mounting bracket<\/li><li>Default settings information<\/li><\/ol><style>#heroic-styled-list-4990a502-00ab-42b6-ba33-52c7e0bc7aa2 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Connections<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-1024x768.png\" alt=\"\" class=\"wp-image-1754\" style=\"width:504px;height:378px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-29.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">MultiSensor LAN View Connectors<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e49c4d8d-70ff-43cf-82bc-065115402805\"><ol class=\"fa-ul\"><li>Kentix system port (type A)<\/li><li>Ethernet port with Power over Ethernet (100MBit, PoE Class 2)<\/li><li>MicroSD card slot<\/li><\/ol><style>#heroic-styled-list-e49c4d8d-70ff-43cf-82bc-065115402805 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h2 class=\"wp-block-heading\">Connection of extensions at the system port<\/h2>\n\n<p class=\"wp-block-paragraph\">Additional system components such as leakage sensors, door contacts or external alarms from UPS or air conditioning units can be connected via the Kentix system port. The system port has 2 digital inputs and 2 digital outputs which are available via a RJ45 socket.  <\/p>\n\n<p class=\"wp-block-paragraph\">An extension module (ORDER CODE: KIO3) is required to connect external alarms. Above this, 2 potential-free contacts and 2 changeover relays can be wired.<\/p>\n\n<p class=\"wp-block-paragraph\">A commercially available network patch cable (unshielded\/shielded) with a length of up to 20 m can be used as the cable connection between the Kentix system port and the system component.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">The Kentix system port is not a network port. Avoid connecting to network ports, especially PoE devices. The port is a Kentix specific expansion port and is only expandable with components designed for it.<br>Pins 4\/5\/8 are only enabled for internal use and must not be wired.  <\/p>\n\n<p class=\"wp-block-paragraph\">The assignment of the system port<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>System port (type: RJ45)<\/th><th>Assignment of the contacts<\/th><\/tr><\/thead><tbody><tr><td><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"177\" class=\"wp-image-1399\" style=\"width: 150px;\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort.png\" alt=\"\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort.png 598w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-339x400.png 339w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-127x150.png 127w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-42x50.png 42w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-51x60.png 51w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/SystemPort-85x100.png 85w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/td><td>1. internal system voltage (GND) &#8211; Not for external <strong> use*<\/strong>.<br\/>2. output 1 (open collector, max. 100mA)<br\/>3. output 2 (open collector, max 100mA)<br\/>4. external voltage \/ BUS (depending on device type)<br\/>5. external voltage \/BUS (depending on device type)<br\/>6. input 1 (potential-free circuit)<br\/>7. input 2 (potential-free circuit)<br\/>8. internal system voltage (5\/24VDC) &#8211; not for external <strong> use*<\/strong><br\/><br\/><strong>* These connections are for internal use only<\/strong><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Kentix system port assignment<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Connection of a leakage sensor to the system port<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001.png\" alt=\"\" class=\"wp-image-10003\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-3833ef4d-a097-43a5-99e5-317612c23dcd\"><ol class=\"fa-ul\"><li>Leakage sensor<\/li><li>MultiSensor<\/li><\/ol><style>#heroic-styled-list-3833ef4d-a097-43a5-99e5-317612c23dcd li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">The leakage sensor is connected directly to the system port of the MultiSensor.<\/p>\n\n<h3 class=\"wp-block-heading\">Connection of an alarm siren to the system port<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002.png\" alt=\"\" class=\"wp-image-10005\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.002-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-7dca2e42-ad9e-4c7c-a95a-eac7f7341248\"><ol class=\"fa-ul\"><li>24V DC power supply unit<\/li><li>Alarm siren<\/li><li>MultiSensor<\/li><li>KIO2<\/li><li>RJ45 T-adapter<\/li><\/ol><style>#heroic-styled-list-7dca2e42-ad9e-4c7c-a95a-eac7f7341248 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">The alarm siren is supplied with 24V DC via the KIO2 expansion module and a power supply unit. The alarm siren is also connected to the MultiSensor via the RJ45 T adapter.<\/p>\n\n<h3 class=\"wp-block-heading\">Connection of a leakage sensor and an alarm siren to the system port<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003.png\" alt=\"\" class=\"wp-image-10007\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/07\/KMS-connection-Systemport.003-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-88b55f8b-6366-4b22-9fc8-3980943971c4\"><ol class=\"fa-ul\"><li>24V DC power supply unit<\/li><li>Alarm siren<\/li><li>Leakage sensor<\/li><li>MultiSensor<\/li><li>KIO2<\/li><li>RJ45 T-adapter<\/li><li>RJ45 T-adapter<\/li><\/ol><style>#heroic-styled-list-88b55f8b-6366-4b22-9fc8-3980943971c4 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\">The alarm siren is supplied with 24V DC via the KIO2 expansion module and a power supply unit. The alarm siren is also connected to the MultiSensor via two RJ45 T-adapters. The leakage sensor is also connected to the second T-adapter.<\/p>\n\n<h2 class=\"wp-block-heading\">Factory settings<\/h2>\n\n<p class=\"wp-block-paragraph\">For initial configuration, use the IP address printed on the device or the address assigned via DHCP in a web browser (HTTPS). Please note the network settings of your connected PC.<\/p>\n\n<p class=\"wp-block-paragraph\">The factory IP addresses at a glance:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-white-background-color has-background\"><tbody><tr><td><strong>SiteManager and AlarmManager<\/strong><\/td><td>192.168.100.222<\/td><\/tr><tr><td><strong>MultiSensor<\/strong><\/td><td>192.168.100.223<\/td><\/tr><tr><td><strong>AccessManager<\/strong><\/td><td>192.168.100.224<\/td><\/tr><tr><td><strong>PowerManager<\/strong><\/td><td>192.168.100.225<\/td><\/tr><tr><td><strong>SmartPDU<\/strong><\/td><td>192.168.100.226<\/td><\/tr><tr><td><strong>Leakage sensor<\/strong><\/td><td>192.168.100.227<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Factory IP addresses, subnet mask: 255.255.255.0<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">For devices with a firmware version lower than 8.x.x, the login data for the preset administrator account are: admin \/ password<\/p>\n\n<h2 class=\"wp-block-heading\">Reset to factory settings<\/h2>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3\"><ol class=\"fa-ul\"><li>Restart the device (disconnect and reconnect the power supply).<\/li><li>The status LED lights up briefly and then goes out.<\/li><li>As soon as the status LED lights up green continuously, press and hold the reset button for 15 seconds until the device emits an acoustic feedback.<\/li><li>The device loads the factory settings and performs a restart.<\/li><li>After approx. 2 minutes, the device can be reached with the factory settings.<\/li><\/ol><style>#heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>All existing settings and data will be irrevocably deleted !<\/strong><br><strong>We recommend regular backup of the system<\/strong>.<\/p>\n\n<h2 class=\"wp-block-heading\">Assembly instructions<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix MultiSensors are equipped with various individual sensors. To ensure optimum evaluation and functional cooperation of the sensors, please observe the following basic installation instructions:<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--noicon\">-Do not mount over radiators or air outlets or direct sources of heat\/cold.<br>-Avoid moving objects such as fans, plants, trees, flags or similar in the detection field.<br>-Do not cover the sensor. The PIR sensor always requires direct visual contact for detection<br>-Do not mount in the direct air flow of air conditioning outlets<\/p>\n\n<h2 class=\"wp-block-heading\">Detection range of the integrated PIR motion detector<\/h2>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-1024x768.png\" alt=\"\" class=\"wp-image-2622\" width=\"623\" height=\"467\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik.png 2048w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><figcaption class=\"wp-element-caption\">Detection range of the PIR<\/figcaption><\/figure>\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--noicon is-style-info\"><a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/what-has-to-be-considered-when-mounting-multisensors\/\" target=\"_blank\">More information about mounting MultiSensors here.<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Calibration of the room temperature measurement<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix MultiSensors record all important environmental values of a room, including the room temperature. In order to achieve the most accurate temperature possible and to trigger an alarm if the room temperature exceeds the limit value, we recommend calibrating the temperature measurement at the final installation location. This is especially necessary for sensors with Ethernet (PoE) connection, since a certain intrinsic heat falsifies the measurement. For MultiSensors with radio and battery supply, the influence of the intrinsic heat is not present.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Kentix MultiSensors are not calibrated measuring devices, but alarm devices whose measuring accuracy is completely sufficient for reliable reporting and documentation of limit value violations.<\/p>\n\n<p class=\"wp-block-paragraph\">However, in order to obtain a good measurement result with reproducible measured values in the event of an alarm, the MultiSensor should be calibrated to the respective installation location after installation. To do this, the temperature in the immediate vicinity (approx. 5-10 cm away) of the MultiSensor must be measured comparatively with a room thermometer that is as accurate as possible. If there is a deviation in temperature between the MultiSensor and the thermometer, the temperature value can be corrected. This is done by entering the determined temperature difference between the MultiSensor and the room thermometer as a correction offset in the KentixONE software. The correction also has a direct influence on the measurement of the relative humidity and on the dew point calculation of the MultiSensor.<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Step<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Install MultiSensor at the destination.<\/td><td>The position and orientation of the sensor should not be changed afterwards.<br\/>Please note the following:<br\/>&#8211; Mount with the X air opening facing downwards<br\/>&#8211; Do not mount in the air flow<br\/>&#8211; Ventilation vents of the sensor must be unobstructed<\/td><\/tr><tr><td>Perform configuration of the MultiSensor with Kentix ONE.<\/td><td><\/td><\/tr><tr><td>At the earliest 30 minutes after commissioning<br\/>, adjust the temperature of the MultiSensor to the room temperature.<\/td><td>To do this, measure the temperature with an external reference thermometer in the immediate vicinity, approx. 5-10 cm from the MultiSensor. It should be noted that this thermometer also acclimatizes to the room and displays the correct room temperature only after a few minutes.<\/td><\/tr><tr><td>If a difference between the MultiSensor and the thermometer is detected, this can be entered in the &#8220;Offset&#8221; field in the KentixONE configuration of the MultiSensor. After saving, the sensor then provides the corrected measured value.<\/td><td>The offset can only be specified by whole degrees, i.e. without decimal places.<br\/>This results in an accuracy for the temperature of +\/- 0.5 degrees.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Configuration with KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">The device is configured via the web browser in KentixONE. The device must be accessible to the central KentixONE instance on the network side. Depending on the device type, a communication key and the IP address or DHCP name of the central KentixONE instance must also be set on the device (MultiSensors, AccessManager, SmartPDU). IP cameras or IO modules, on the other hand, can be integrated directly into KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software can be found in the <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> section and the associated documentation.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Before starting the configuration, make sure that the software on all network-compatible Kentix devices is up-to-date. The version status must match on all devices.<br><strong>You can perform a software update for your KentixONE main instance and all connected satellites at any time via &#8220;System &#8211; Update&#8221;.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATA SHEET MULTISENSOR-LAN Overview The MultiSensor-LAN integrates a large number of individual sensors in one compact device and monitors their measured values. The MultiSensor-LAN is optimized for monitoring closed rooms and is typically mounted on or near the ceiling. The MultiSensor-LAN is network-compatible and is supplied with power via Power&#8230;<\/p>\n","protected":false},"author":6,"featured_media":603,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[123],"ht-kb-tag":[],"class_list":["post-4150","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-network-multisensors"],"custom_fields":{"kentix_order_code":["KMS-LAN-B, KMS-LAN-W, KMS-LAN-B-BLE, KMS-LAN-W-BLE"],"kentix_skill_level":["1"]},"categories":[{"slug":"network-multisensors","name":"Network MultiSensors","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-B-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4150"}],"version-history":[{"count":38,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4150\/revisions"}],"predecessor-version":[{"id":12501,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4150\/revisions\/12501"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/603"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4150"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4150"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}