{"id":4117,"date":"2023-02-14T17:04:43","date_gmt":"2023-02-14T16:04:43","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/multisensor-rf-bat-radio-operating-instructions\/"},"modified":"2026-03-20T13:51:33","modified_gmt":"2026-03-20T12:51:33","slug":"multisensor-rf-bat-radio-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/multisensor-rf-bat-radio-operating-instructions\/","title":{"rendered":"MultiSensor-ROOM (BLE radio) &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/multisensor-room-data-sheet\/\" target=\"_blank\" rel=\"noreferrer noopener\">DATASHEET MULTISENSOR-ROOM<\/a><\/pre>\n\n<p class=\"wp-block-paragraph\">The MultiSensor-ROOM-BLE is a battery-operated MultiSensor that can be networked via radio. The sensor is particularly suitable for cost-effective and wireless room monitoring.<\/p>\n\n<p class=\"wp-block-paragraph\">The MultiSensor-ROOM-BLE requires a suitable remote station for wireless operation. The network-capable MultiSensors (MultiSensor-LAN-BLE or MultiSensor-TI-BLE), which also act as a wireless Ethernet gateway, form this wireless remote station. <\/p>\n\n<p class=\"wp-block-paragraph\">A SiteManager or AlarmManager in the MAIN-DEVICE operating mode is required for central management. Teach-in and configuration are performed entirely via the KentixONE web interface. The wireless range between the gateway (MultiSensor-LAN-BLE or MultiSensor-TI-BLE) and MultiSensor-ROOM-BLE can be up to 20m. Up to 25 wireless sensors can be taught-in to a wireless Ethernet gateway.<\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h3 class=\"wp-block-heading\">Front<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1080\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001.png\" alt=\"\" class=\"wp-image-10208\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001.png 1920w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.001-100x56.png 100w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><figcaption class=\"wp-element-caption\">MultiSensor-ROOM front view<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-6c70d591-fbf6-43dc-aa50-6395f4afcf41\"><ol class=\"fa-ul\"><li>Status LED : <br><strong>GREEN: <\/strong>POWER OK, no alarms pending<br> RED<strong>: <\/strong>POWER OK, alarms pending<\/li><li>PIR sensor<\/li><\/ol><style>#heroic-styled-list-6c70d591-fbf6-43dc-aa50-6395f4afcf41 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Back<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1080\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002.png\" alt=\"\" class=\"wp-image-10210\" style=\"aspect-ratio:1.5536231884057972;width:670px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002.png 1920w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.002-100x56.png 100w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><figcaption class=\"wp-element-caption\">MultiSensor-ROOM Rear view<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-63cffe9a-74f4-4cbd-8441-369a5ecbe71b\"><ol class=\"fa-ul\"><li>Teach-in key: This key is used to teach the device into the wireless network. To teach-in the sensor, start the teach-in process in the AlarmManager web interface and then press the teach-in button for 3 seconds until a beep is heard<\/li><li>Mounting bracket<\/li><li>Battery compartment: one 3.6V 1\/2AA battery is required to operate the device<\/li><\/ol><style>#heroic-styled-list-63cffe9a-74f4-4cbd-8441-369a5ecbe71b li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h2 class=\"wp-block-heading\">Connect with radio network<\/h2>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-d7cbc9c4-ed42-4538-b15e-559d4f88a81c\"><ol class=\"fa-ul\"><li>MultiSensor-ROOM-BLE must be within radio range of a fully configured wireless Ethernet gateway (MultiSensor-LAN-BLE or MultiSensor-TI-BLE). It is recommended to perform the teach-in process closer than the actual placement range, about 3-5m.<\/li><li>Start the teach-in process in the KentixONE web interface in the &#8220;Detail View&#8221; area via the &#8220;Add device&#8221; button.<\/li><li>Now press the teach-in button on the MultiSensor-ROOM-BLE for approx. 3 seconds with the battery inserted. After approx. 5-10 seconds, the MultiSensor-ROOM-BLE should be recognized as a new sensor. <\/li><li>Finally, carry out the configuration and place the MultiSensor-ROOM-BLE in the intended mounting location.<\/li><\/ol><style>#heroic-styled-list-d7cbc9c4-ed42-4538-b15e-559d4f88a81c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Due to the energy-saving functions of the MultiSensor-ROOM-BLE, arming for a motion alarm is only activated after approx. 5 minutes; this must be taken into account when testing the motion detection functionality.<\/p>\n\n<h2 class=\"wp-block-heading\">Application example<\/h2>\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1080\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003.png\" alt=\"\" class=\"wp-image-10213\" style=\"aspect-ratio:1.3333333333333333;width:660px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003.png 1920w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/kms-room.003-100x56.png 100w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n\n<h2 class=\"wp-block-heading\">Configuration with KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">The device is configured via the web browser in KentixONE. The device must be accessible to the central KentixONE instance on the network side. Depending on the device type, a communication key and the IP address or DHCP name of the central KentixONE instance must also be set on the device (MultiSensors, AccessManager, SmartPDU). IP cameras or IO modules, on the other hand, can be integrated directly into KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software can be found in the <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> section and the associated documentation.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Before starting the configuration, make sure that the software on all network-compatible Kentix devices is up-to-date. The version status must match on all devices.<br><strong>You can perform a software update for your KentixONE main instance and all connected satellites at any time via &#8220;System &#8211; Update&#8221;.<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATASHEET MULTISENSOR-ROOM The MultiSensor-ROOM-BLE is a battery-operated MultiSensor that can be networked via radio. The sensor is particularly suitable for cost-effective and wireless room monitoring. The MultiSensor-ROOM-BLE requires a suitable remote station for wireless operation. The network-capable MultiSensors (MultiSensor-LAN-BLE or MultiSensor-TI-BLE), which also act as a wireless Ethernet gateway, form&#8230;<\/p>\n","protected":false},"author":4,"featured_media":603,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[122],"ht-kb-tag":[],"class_list":["post-4117","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-radio-multisensors"],"custom_fields":{"kentix_skill_level":["1"],"kentix_order_code":["KMS-ROOM-B-BLE, KMS-ROOM-W-BLE"]},"categories":[{"slug":"radio-multisensors","name":"Radio MultiSensors","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-B-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4117"}],"version-history":[{"count":25,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4117\/revisions"}],"predecessor-version":[{"id":12900,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4117\/revisions\/12900"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/603"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4117"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4117"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}