{"id":4103,"date":"2023-01-20T17:04:05","date_gmt":"2023-01-20T16:04:05","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/smartpdu-40he-switched-3x16-32a-data-sheet\/"},"modified":"2026-02-04T15:28:11","modified_gmt":"2026-02-04T14:28:11","slug":"smartpdu-40he-switched-3x16-32a-data-sheet","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/smartpdu-40he-switched-3x16-32a-data-sheet\/","title":{"rendered":"SmartPDU 40HE SWITCHED, 3&#215;16\/32A (up to 22kVA) &#8211; Datasheet"},"content":{"rendered":"\n<figure class=\"wp-block-table is-style-regular\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Types<\/strong><\/th><th><strong>KPMDU-RCSW-2406C13C19-3-32<\/strong><\/th><th>KPMDU-RCSW-4800C13C19-3-32<\/th><th><strong>KPMDU-RCSW-2406C13C19-3-16<\/strong><\/th><th><strong>KPMDU-RCSW-4800C13C19-3-1<\/strong>6<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Rated power, voltage<\/strong><\/td><td>up to 22kVA, 230\/400V<\/td><td>up to 13.8kVA, 230\/400V<\/td><td>up to 11kVA, 230\/400V<\/td><td>up to 11kVA, 230\/400V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Connector plug<\/strong><\/td><td>CEE plug<strong>(RED<\/strong>) according to IEC60309, 5-pole, 32A\/230\/400V<\/td><td>CEE plug<strong>(RED<\/strong>) according to IEC60309, 5-pole, 32A\/230\/400V<\/td><td>CEE plug<strong>(RED<\/strong>) according to IEC60309, 5-pole, 16A\/230\/400V<\/td><td>CEE plug<strong>(RED<\/strong>) according to IEC60309, 5-pole, 16A\/230\/400V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Connection cable<\/strong><\/td><td>Length 3m, rubber sheathed cable H07RN-F-5G6<\/td><td>Length 3m, rubber sheathed cable H07RN-F-5G6<\/td><td>Length 3m, rubber hose cable H07RN-F-5G2.5<\/td><td>Length 3m, rubber hose cable H07RN-F-5G2.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Sockets C13 (IEC60320) switchable, measured<\/strong>\n        <\/td><td>24, individually switchable (bistable relays) with LED<\/td><td>48, individually switchable (bistable relays) with LED<\/td><td>24, individually switchable (bistable relays) with LED<\/td><td>48, individually switchable (bistable relays) with LED<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Sockets C19 (IEC60320) switchable, measured<\/strong>\n        <\/td><td>6, individually switchable (bistable relays) with LED<\/td><td>0<\/td><td>6, individually switchable (bistable relays) with LED<\/td><td>0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Locking sockets<\/strong><\/td><td colspan=\"4\">IEC-LOCK for C13\/C19<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Fuse circuit breaker<\/strong><\/td><td>6 x 16A C-type, 6kA short-circuit current, interlocked<\/td><td>6 x 16A C-type, 6kA short-circuit current, interlocked<\/td><td>3 x 10A C-type, 6kA short-circuit current, interlocked<br\/>3 x 16A C-type, 6kA short-circuit current, interlocked<\/td><td>6 x 10A C-type, 6kA short circuit current, interlocked<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"1\"><strong>Current measurement per fuse<\/strong><\/td><td colspan=\"4\">Integrated individual measurements of the 6 fuse ranges (U, I, P, W) with reference to the calibrated\n overall measurement<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Current measurement (calibrated)<\/strong><\/td><td colspan=\"4\">Integrated, calibrated total current measurement with separation according to phases L1\/2\/3, accuracy Class B\n (MID, EN 50470-3)<br\/>Minimum current 250mA, maximum current 3x32A<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Residual current measurement (RCM)<\/strong><\/td><td colspan=\"4\">Integrated AC\/DC sensitive residual current measurement in accordance with IEC 60664-1<br\/>\u00b1300mA\/100mA (RMS),\n Accuracy &lt;0.2mA<br\/>Frequency range DC 0.2kHz<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Connectivity<\/strong><\/td><td colspan=\"4\">Ethernet (10\/100MBit), PoE<br\/>Modbus TCP<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Kentix system socket (type B)<\/strong><\/td><td colspan=\"4\">RJ45 with Kentix-specific assignment for system extensions<br\/>2 x digital input (e.g.\n door contacts, leakage detector, ext. alarms)<br\/>1 x system BUS <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"1\"><strong>Rack locking lever connection\n (access control)<\/strong><\/td><td colspan=\"4\">Connection of two electronic rack levers for access control with RFID\/PIN via\n system socket<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Communication and security<\/strong><\/td><td colspan=\"4\">HTTPS (certificate), integrated web server, ReSt-API<br\/>Protocols: SNMP V2\/3 (GET, TRAP), NTP,\n SMTP, DHCP, DNS<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Management<\/strong><\/td><td colspan=\"4\">Master-slave management, SmartPDU or PowerManager can be configured as master, up to 100 slaves\n per master, automatic Software Deployment<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Measurement\/communication objects<\/strong><\/td><td colspan=\"4\">Voltage (V) L1\/L2\/L3\/Total<br\/>Current (A) L1\/L2\/L3\/Total<br\/>Consumption (kWh)\n  L1\/L2\/L3\/Total<br\/>Active power (W) L1\/L2L3\/total<br\/>Apparent power (VA) L1\/L2\/L3\/total<br\/>Reactive power\n  (VAR) L1\/L2\/L3\/total<br\/>Effective factor (cos phi)<br\/>Frequency (Hz)<br\/>Phase monitoring L1\/L2\/L3<br\/>Differential current\n  AC<br\/>Differential current DC<br\/>Fuse status L1\/L2\/L3<br\/>Temperature (\u00b0C)<br\/>Relative humidity\n  (%)<br\/>Dew point (\u00b0C)<br\/>Vibration (G)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Display (LCD)<\/strong><\/td><td colspan=\"4\">Illuminated LCD display for total measurement (power, current, voltage, consumption)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Optical signaling<\/strong><\/td><td colspan=\"4\">LED with RED\/GREEN (operation, alarm\/error status)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Acoustic signaling<\/strong><\/td><td colspan=\"4\">Signal generator with 80dB, 2.3kHz (alarm\/fault conditions)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Factory state<\/strong><\/td><td colspan=\"4\">Button for factory reset <strong>(default IP: 192.168.100.226<\/strong>)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Power dissipation<\/strong><\/td><td colspan=\"4\">approx. 80W (full load)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Housing<\/strong><\/td><td colspan=\"4\">Sheet metal, powder-coated RAL9005, protection class 1, protection rating IP20, mounting bracket can be mounted at 5U intervals\n <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"1\"><strong>Size<\/strong><\/td><td colspan=\"4\">1770 x 78.2 x 62.5 mm (HxWxD)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Weight<\/strong><\/td><td colspan=\"4\">approx. 11,5kg<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Environmental conditions<\/strong><\/td><td colspan=\"4\">-10\u00b0C to 55\u00b0C, humidity 5-95%, storage temperature: -20\u00b0C to 60\u00b0C<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Exams<\/strong><\/td><td colspan=\"4\">CE (2014\/30\/EC, 2014\/35\/EC, 2011\/65\/EU)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Electrical safety<\/strong><\/td><td colspan=\"4\">DGUV-V3 testing, VDE 0105-100<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Marking<\/strong><\/td><td colspan=\"4\">Serial number (barcode), additional free marking area front panel (60x30mm)<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Types KPMDU-RCSW-2406C13C19-3-32 KPMDU-RCSW-4800C13C19-3-32 KPMDU-RCSW-2406C13C19-3-16 KPMDU-RCSW-4800C13C19-3-16 Rated power, voltage up to 22kVA, 230\/400V up to 13.8kVA, 230\/400V up to 11kVA, 230\/400V up to 11kVA, 230\/400V Connector plug CEE plug(RED) according to IEC60309, 5-pole, 32A\/230\/400V CEE plug(RED) according to IEC60309, 5-pole, 32A\/230\/400V CEE plug(RED) according to IEC60309, 5-pole, 16A\/230\/400V CEE plug(RED) according&#8230;<\/p>\n","protected":false},"author":2,"featured_media":7197,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[94,236],"ht-kb-tag":[],"class_list":["post-4103","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-data-sheets-en","ht_kb_category-smartpdu-archive"],"custom_fields":{"kentix_order_code":["KPMDU-RCSW-2406C13C19-3-32, KPMDU-RCSW-2406C13C19-3-16, KPMDU-RCSW-4800C13C19-3-32, KPMDU-RCSW-4800C13C19-3-16"]},"categories":[{"slug":"data-sheets-en","name":"Datasheets","shortName":""},{"slug":"smartpdu-archive","name":"SmartPDU Archive","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-RC-4800C13C19-2_1920x1920-150x13.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4103","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4103"}],"version-history":[{"count":20,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4103\/revisions"}],"predecessor-version":[{"id":12621,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4103\/revisions\/12621"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/7197"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4103"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4103"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4103"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}