{"id":4096,"date":"2023-02-15T13:52:28","date_gmt":"2023-02-15T12:52:28","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/keypad-touch-operating-guide-archive\/"},"modified":"2026-08-12T10:00:35","modified_gmt":"2026-08-12T08:00:35","slug":"keypad-touch-operating-guide-archive","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/keypad-touch-operating-guide-archive\/","title":{"rendered":"KeyPad-Touch &#8211; USER MANUAL (ARCHIVE)"},"content":{"rendered":"\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">This device is not compatible with KentixONE<\/p>\n\n<p class=\"wp-block-paragraph\">The KeyPad is used to arm and disarm the AlarmManager on-site. Like the MultiSensors, the KeyPad is integrated into the AlarmManager\u2019s ZigBee\u00a9 wireless network. Please note, however, that the KeyPad does not function as a router and cannot affect the network\u2019s range.  <\/p>\n\n<p class=\"wp-block-paragraph\">The KeyPad turns on when any key is pressed. The maximum operating time is then approx. 10 seconds. Within this time, an assigned alarm zone can be armed or disarmed.  <\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind may be made to Kentix GmbH products, with the exception of those described in the relevant instructions.<br>When installing Kentix devices, certain degrees of protection must be guaranteed.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the devices or components caused by incorrect installation. Kentix accepts no liability for incorrectly programmed units.<br>Kentix accepts no liability for faults, material damage or other damage. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device from<br>moisture, dirt and damage during transportation, storage and operation.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use the products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained specialist personnel in accordance with the instructions.<br>Do not charge, short-circuit, open or heat batteries.<br>Observe the correct polarity when inserting the batteries.<br>The devices must always be operated with the batteries intended for the product.<br>When changing the batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h3 class=\"wp-block-heading\">Front<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front.png\" alt=\"\" class=\"wp-image-3838\" style=\"width:400px;height:300px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front.png 800w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-front-100x75.png 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">KeyPad touch front<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Key layout<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-1024x768.jpeg\" alt=\"\" class=\"wp-image-3840\" style=\"width:442px;height:330px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-1024x768.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-1536x1152.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema-100x75.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KKPT-schema.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">KeyPad touch key layout<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-2de2c6fc-ecd2-4cd4-8d27-f736014bde49\"><ol class=\"fa-ul\"><li>Arming &#8211; Leaving the Room<br\/>OK: 5-second audible signal (on\/off), arming LED flashes green <i class=\"far fa-circle-half-stroke\"><\/i>, MultiSensors emit an audible signal according to the set delay time.<br\/>Not OK: 3-second audible signal (on\/off), arming LED flashes red  <i class=\"far fa-circle-half-stroke\"><\/i><\/li><li>Disabling &#8211; Entering a room<br\/>OK: 1-second continuous audible signal on the keypad and MultiSensors; LED stays on continuously  <i class=\"fas fa-circle\"><\/i><\/li><li>RFID reading range: Hold the RFID card as centered as possible on the reader. The function is executed immediately after the correct reading. <\/li><\/ol><style>#heroic-styled-list-2de2c6fc-ecd2-4cd4-8d27-f736014bde49 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Internal controls<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-1024x768.png\" alt=\"\" class=\"wp-image-1856\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-33.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-cff3ef02-3f0e-4951-9d64-88ecb4b79b11\"><ol class=\"fa-ul\"><li>Battery compartment: two AAA 1.5 V batteries are required to operate the device<\/li><li>Teach-in key: This key is used to teach the device into the wireless network. To teach-in the sensor in KentixOne, start the teach-in process and then press the teach-in button for 3sec. Press until a signal tone is heard  <\/li><\/ol><style>#heroic-styled-list-cff3ef02-3f0e-4951-9d64-88ecb4b79b11 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h2 class=\"wp-block-heading\">Connect with WLAN<\/h2>\n\n<p class=\"wp-block-paragraph\">To add a KeyPad-Touch to KentixONE, select the &#8220;+&#8221; icon under the &#8220;Alarm Zones&#8221; heading on the dashboard, and then select &#8220;MultiSensor (Wireless).&#8221;<\/p>\n\n<p class=\"wp-block-paragraph\">Press the teach-in button for 3 seconds, which you reach via the recess on the back of the housing (2), until an acoustic signal sounds<\/p>\n\n<p class=\"wp-block-paragraph\">The sensor should be detected within 15-20 seconds. The configuration mask for the sensor is then opened directly. The teach-in process is now complete  <\/p>\n\n<h2 class=\"wp-block-heading\">Operation via RFID<\/h2>\n\n<p class=\"wp-block-paragraph\">To operate the KeyPad using an RFID card, you can use the card for authentication instead of the 4-digit PIN.<br\/>To do this, activate the KeyPad and then hold your RFID card in front of the X.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">Only \u201cArmed-Active\u201d alarms can be triggered via the KeyPad.<br\/><br\/>\u201cContinuously Active\u201d alarms are executed or reported regardless of the armed or disarmed status of the AlarmManager or the alarm zone.<\/p>\n\n<h2 class=\"wp-block-heading\">Teach-in user \/ RFID cards<\/h2>\n\n<p class=\"wp-block-paragraph\">New RFID cards are read in via the user configuration in KentixOne on a KeyPad.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The KeyPad is used to arm and disarm the AlarmManager on-site. Like the MultiSensors, the KeyPad is integrated into the AlarmManager\u2019s ZigBee\u00a9 wireless network. Please note, however, that the KeyPad does not function as a router and cannot affect the network\u2019s range. The KeyPad turns on when any key is&#8230;<\/p>\n","protected":false},"author":4,"featured_media":3846,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"ht-kb-category":[138],"ht-kb-tag":[],"class_list":["post-4096","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartmonitoring-archive-en"],"custom_fields":{"kentix_order_code":["KKPT"],"kentix_legacy_product":["1"]},"categories":[{"slug":"smartmonitoring-archive-en","name":"SmartMonitoring Archive","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-28-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4096","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4096"}],"version-history":[{"count":11,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4096\/revisions"}],"predecessor-version":[{"id":14578,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4096\/revisions\/14578"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/3846"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4096"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4096"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}