{"id":4095,"date":"2023-02-16T13:29:16","date_gmt":"2023-02-16T12:29:16","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/io-modules-operating-instructions\/"},"modified":"2025-08-13T15:07:27","modified_gmt":"2025-08-13T13:07:27","slug":"io-modules-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/io-modules-operating-instructions\/","title":{"rendered":"Expansion module (Ethernet) &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted has-theme-default-color has-text-color has-link-color wp-elements-293be1926547e68ce439f6748dd16e7b\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-8-analog-inputs-art-kio7017-data-sheet\/\">DATASHEET KIO7017<\/a>,<br><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-8-inputs-8-outputs-art-kio7052-data-sheet\/\">DATASHEET KIO7052<\/a>,<br><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-16-alarm-inputs-art-kio7053-data-sheet\/\">DATASHEET KIO7053<\/a>,<br><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-8-inputs-8-outputs-datasheet\/\">DATASHEET KIO7060<\/a>,  <br><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/quick-start-manual-smartmonitoring-pdf\/\" target=\"_blank\" rel=\"noreferrer noopener\">Quick Start Manual<\/a><\/pre>\n\n\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The expansion module (Ethernet) integrates a variety of inputs and outputs in one compact device. The expansion module is used to connect external alarm messages to KentixONE. The module is network-compatible and is powered either via Power over Ethernet (PoE) or an external power supply (12-30VDC, 4.5W).<br><br>The configuration of the network settings of the expansion module is done via the web browser. The configuration of the alarm and display logic takes place on the Main Device.  <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Variants<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There are 3 expansion modules (Ethernet) available, which differ in the number of inputs and outputs. The differences are shown in the following table:<\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter has-small-font-size\"><table class=\"has-fixed-layout\"><thead><tr><th>Model<\/th><th>KIO7052<\/th><th>KIO7053<\/th><th>KIO7017<\/th><th>KIO7060<\/th><\/tr><\/thead><tbody><tr><td><\/td><td><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KIO52_Terminal.jpg\" alt=\"\"><\/td><td><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KIO53_Terminal.jpeg\" alt=\"\"><\/td><td><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KIO17_Terminal.jpg\" alt=\"\"><\/td><td><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KIO17_Terminal.jpg\" alt=\"\"><\/td><\/tr><tr><td>Digital inputs<\/td><td> 8<\/td><td>16<\/td><td>&#8211;<\/td><td>6<\/td><\/tr><tr><td>Digital outputs<\/td><td>8<\/td><td>&#8211;<\/td><td>4<\/td><td>&#8211;<\/td><\/tr><tr><td>Analog inputs<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>8<\/td><td>&#8211;<\/td><\/tr><tr><td>Relay outputs<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>6<\/td><\/tr><tr><td>Protocol<\/td><td colspan=\"4\">Modbus TCP<\/td><\/tr><tr><td>IP Port<\/td><td colspan=\"4\">502 TCP<\/td><\/tr><tr><td>Configuration network<\/td><td colspan=\"4\">Web Server HTTP, Port 80Default IP: 192.168.255.1 (Admin\/Admin)<\/td><\/tr><tr><td>Configuration via KentixONE<\/td><td colspan=\"4\">Configuration is done completely via KentixONE. <br>Only IP settings on IO module\n          necessary.<br>Alarm and display logic is freely adjustable in KentixONE.<\/td><\/tr><tr><td>Power supply<\/td><td colspan=\"4\">PoE (Class 2) or external 12-30VDC<\/td><\/tr><tr><td>Mounting<\/td><td colspan=\"4\">DIN rail, stackable<\/td><\/tr><tr><td>Connection variant 1<\/td><td>SINK<br>Readback as 1<br>+10 ~ +50VDC<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7052_RB-as-1_1050VDC_SINK-1024x331.jpeg\" alt=\"\">\n        <\/td><td>NC &#8211; Normally Closed<br>Potential-free wiring!<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-1024x264.jpeg\" alt=\"\"><br>\n        <\/td><td>Voltage Input Differential<br>Default 0-10V<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-1024x232.jpeg\" alt=\"\"><br><\/td><td>NC &#8211; Normally Closed<br>Potential-free wiring!<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-1024x264.jpeg\" alt=\"\"><br>\n        <\/td><\/tr><tr><td>Connection variant 2<\/td><td>SINK<br>Readback as 0<br>OPEN or &lt;4 VDC<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7052_RB-as-0_open-or-4-VDC_SOURCE-1024x336.jpeg\" alt=\"\"><\/td><td>NO &#8211; Normally Opened<br>Potential-free wiring!<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-1024x264.jpeg\" alt=\"\"><\/td><td>Voltage Input Single Ended<br>Default 0-10V<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-1024x227.jpeg\" alt=\"\"><\/td><td>NO &#8211; Normally Opened<br>Potential-free wiring!<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-1024x264.jpeg\" alt=\"\"><\/td><\/tr><tr><td>Connection variant 3<\/td><td>SOURCE<br>Readback as 1<br>+10 ~ +50 VDC<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7052_RB-as-1_1050VDC_SOURCE-1024x327.jpeg\" alt=\"\">\n        <\/td><td><br>&#8211;<\/td><td>Current Input 4-20mA*<br>Implement jumper!<img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-1024x274.jpeg\" alt=\"\"> <\/td><td><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KIO7060-Relay-ON.png\" alt=\"\"><\/td><\/tr><tr><td>Connection variant 4<\/td><td>SOURCE<br>Readback as 0<br>OPEN or &lt;4 VDC<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7052_RB-as-0_open-or-4-VDC_SOURCE-1024x336.jpeg\" alt=\"\"><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/06\/KIO7060-Relay-OFF-1.png\" alt=\"\"><\/td><\/tr><tr><td>Connection variant 5<\/td><td>DIGITAL OUTPUT<br>ON State<br>Readback as 1<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7052-ON-State-Readback-as-1-1024x321.jpeg\" alt=\"\">\n        <\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Connection variant 6<\/td><td>DIGITAL OUTPUT<br>OFF State<br>Readback as 0<br><img decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7052-OFF-State-Readback-as-0-1024x318.jpeg\" alt=\"\">\n        <\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table KIO70xx <\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Determination of the measuring range for KIO7017<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To change from voltage measurement 0-10V (default) to current measurement 4-20mA the jumper inside the housing must be changed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Factory settings<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Default IP address<\/strong><\/td><td>192.168.255.1<\/td><\/tr><tr><td><strong>Subnet mask<\/strong><\/td><td>255.255.255.0<\/td><\/tr><tr><td><strong>User<\/strong><\/td><td>Admin<\/td><\/tr><tr><td><strong>Password<\/strong><\/td><td>Admin<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Commissioning<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The modules can optionally be supplied with voltage via PoE or via an external power supply unit. When using a power supply unit, be sure to observe the information on the voltage supply in the <a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/de\/?s=KIO70&amp;ht-kb-search=1&amp;lang=de\" target=\"_blank\">data sheet.<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Configuration with KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">The device is configured via the web browser in KentixONE. The device must be accessible to the central KentixONE instance on the network side. Depending on the device type, a communication key and the IP address or DHCP name of the central KentixONE instance must also be set on the device (MultiSensors, AccessManager, SmartPDU). IP cameras or IO modules, on the other hand, can be integrated directly into KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software can be found in the <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> section and the associated documentation.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Before starting the configuration, make sure that the software on all network-compatible Kentix devices is up-to-date. The version status must match on all devices.<br><strong>You can perform a software update for your KentixONE main instance and all connected satellites at any time via &#8220;System &#8211; Update&#8221;.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATASHEET KIO7017,DATASHEET KIO7052,DATASHEET KIO7053,DATASHEET KIO7060, Quick Start Manual Overview The expansion module (Ethernet) integrates a variety of inputs and outputs in one compact device. The expansion module is used to connect external alarm messages to KentixONE. The module is network-compatible and is powered either via Power over Ethernet (PoE) or&#8230;<\/p>\n","protected":false},"author":4,"featured_media":681,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[120],"ht-kb-tag":[],"class_list":["post-4095","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-external-sensors"],"custom_fields":{"kentix_skill_level":["3"],"kentix_order_code":["KIO7053, KIO7052, KIO7060, KIO7017"]},"categories":[{"slug":"external-sensors","name":"External sensors","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO70xx-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4095","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4095"}],"version-history":[{"count":17,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4095\/revisions"}],"predecessor-version":[{"id":11800,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4095\/revisions\/11800"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/681"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4095"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4095"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4095"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}