{"id":4077,"date":"2023-03-01T16:46:34","date_gmt":"2023-03-01T15:46:34","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/smartpdu-40he-operating-instructions\/"},"modified":"2024-10-18T09:03:06","modified_gmt":"2024-10-18T07:03:06","slug":"smartpdu-40he-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/smartpdu-40he-operating-instructions\/","title":{"rendered":"SmartPDU-40U &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/smartpdu-40u-1x16-32a-art-kpmdu-rc-xxxxc13c19-1-xx-data-sheet\/\">DATA SHEET SmartPDU-40U<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">KentixONE Operating mode<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">SiteManager Operation<\/th><th class=\"has-text-align-center\" data-align=\"center\">Stand-alone operation<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/docs.kentix.com\/en\/?post_type=ht_kb&amp;p=6835\">Further information on the operating mode<\/a><\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">The SmartPDU is optimized for power supply of end devices in data and network cabinets with simultaneous power monitoring, consumption data logging and environmental monitoring and is typically mounted in a 19 inch rack. With the integrated PowerManager and MultiSensor, up to 100 SmartPDUs can be easily managed. The integrated PowerManager is network-compatible and is supplied with power via Power over Ethernet (PoE).<br\/><br\/>The SmartPDU can be operated as the main device (operating mode: Main Device) or in a network (operating mode: Satellite Device) with other SmartPDUs. The KentixONE software is already integrated via the integrated web server (HTTPS). Configuration is performed via web browser and, depending on the operating mode, locally on the SmartPDU itself (operating mode: Main Device) or on a central instance such as SiteManager or PowerManager (operating mode: Satellite Device).<br\/><br\/>The SmartPDU has a height of approx. 178cm (40 height units) and thus fits into all common server cabinets from 42 height units. The SmartPDU delivers a maximum output power of up to 22kVA (depending on the version) and is therefore ideally suited for server racks with high power consumption. Depending on the version, the SmartPDU-40U is also available as a two-phase variant so that electronic terminal devices are protected against possible failures by two separate power supplies. The power is supplied via a 3 meter long connection cable and a CEE plug (IEC60309) corresponding to the design.<\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Front<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"234\" height=\"765\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14.png\" alt=\"\" class=\"wp-image-2691\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14.png 234w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14-122x400.png 122w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14-46x150.png 46w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14-15x50.png 15w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14-18x60.png 18w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-14-31x100.png 31w\" sizes=\"auto, (max-width: 234px) 100vw, 234px\" \/><figcaption class=\"wp-element-caption\">SmartPDU-40U Front view<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-ad6331ff-493f-4d1e-858b-67cbb24e189e\"><ol class=\"fa-ul\"><li>Network connection (PoE) and Kentix system socket, Integrated sensors<\/li><li>Connection area 3 (L3) with fuse C10\/C16<\/li><li>Connection area 2 (L2) with fuse C10\/C16<\/li><li>Connection area 1 (L1) with fuse C10\/C16<\/li><li>Current meter with display (MID calibrated) and residual current measurement (RCM) measurement<\/li><li>Power connection depending on type 5-pole 16\/32A or 3-pole 32A, cable length 3m<\/li><\/ol><style>#heroic-styled-list-ad6331ff-493f-4d1e-858b-67cbb24e189e li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports.png\" alt=\"\" class=\"wp-image-7763\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_ports-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-ac519770-28d9-49f8-b476-683a68ff86ad\"><ol class=\"fa-ul\"><li>Reset button<\/li><li>Ethernet port with Power over Ethernet (100MBit, PoE Class 3)<\/li><li>Status LED:<br><strong>GREEN:<\/strong> POWER OK, no alarms pending<br> RED<strong>:<\/strong> POWER OK, alarms pending<\/li><li>Kentix system port (type B)<\/li><\/ol><style>#heroic-styled-list-ac519770-28d9-49f8-b476-683a68ff86ad li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Top view<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001.png\" alt=\"\" class=\"wp-image-8318\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/11\/KPMDU-40U_SD.001-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">SmartPDU-40U SD card<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-daeb390c-c171-4c40-a8b9-ff4f34018143\"><ol class=\"fa-ul\"><li>MicroSD card slot<\/li><\/ol><style>#heroic-styled-list-daeb390c-c171-4c40-a8b9-ff4f34018143 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The SD card is required to perform a mass update or to save automatic data backups.<\/p>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">The micro SD card must be inserted into the PDU in the removed state.<\/p>\n<\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">SmartPDU-40U variants<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>KPMDU-<\/strong> Type <strong>&#8211;<\/strong> Number of sockets <strong>&#8211; Connector plug <\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Type<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Description<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-<\/strong> Number of sockets <strong>&#8211;<\/strong> connector plug<\/td><td class=\"has-text-align-left\" data-align=\"left\">with residual current measurement (RCM)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RCSW-<\/strong> Number of sockets <strong>&#8211;<\/strong> connector plug<\/td><td class=\"has-text-align-left\" data-align=\"left\">with residual current measurement (RCM) and sockets are switchable<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-EM-<\/strong> Number of sockets <strong>&#8211;<\/strong> connector plug<\/td><td class=\"has-text-align-left\" data-align=\"left\">Passive PDU<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Number of sockets<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Description<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> Type <strong>-2406C13C19-<\/strong> Connector plug<\/td><td class=\"has-text-align-left\" data-align=\"left\">24x C13 sockets, 6x C19 sockets<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> Type <strong>-4800C13C19-<\/strong> Connector plug<\/td><td class=\"has-text-align-left\" data-align=\"left\">48x C13 sockets<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Connector plug<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\">Description<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> type <strong>&#8211;<\/strong> number of sockets <strong>-3-32<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">3-phase, 32A per phase<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> type <strong>&#8211;<\/strong> number of sockets <strong>-1-32<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">1-phase, 32A per phase<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> type <strong>&#8211;<\/strong> number of sockets <strong>-3-16<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">3-phase, 16A per phase<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> type <strong>&#8211;<\/strong> number of sockets <strong>-2-16<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">2x 1-phase, 16A per phase<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> type <strong>&#8211;<\/strong> number of sockets <strong>-2-32<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">2x 1-phase, 32A per phase<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-<\/strong> type <strong>&#8211;<\/strong> number of sockets <strong>-6-16<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">2x 3-phase, 16A per phase<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table is-style-regular\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>ORDER-CODES<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-2406C13C19-3-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-2406C13C19-1-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-2406C13C19-3-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-2406C13C19-1-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-3-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-1-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-3-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-1-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-2-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-2-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RC-4800C13C19-6-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RCSW-2406C13C19-3-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RCSW-2406C13C19-3-16<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-RCSW-4800C13C19-3-32<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>KPMDU-EM-2406C13C19-3-32<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"425\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-1024x425.png\" alt=\"\" class=\"wp-image-2665\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-1024x425.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-400x166.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-150x62.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-768x318.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-50x21.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-1536x637.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-2048x849.png 2048w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-60x25.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-9-100x41.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">SmartPDU-40U variants<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Functionalities<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Cable fuse<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Each SmartPDU is equipped exclusively with IEC lock device sockets. This prevents accidental disconnection of the connection cables on the PDU side. When using the appropriate IEC-Lock connection cables, accidental disconnection of the connection cables at the terminal device is prevented. The connection cables are available in black and red.<\/p>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-bottom is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"184\" height=\"184\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11.png\" alt=\"\" class=\"wp-image-2670\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11.png 184w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-150x150.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-50x50.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-60x60.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-11-100x100.png 100w\" sizes=\"auto, (max-width: 184px) 100vw, 184px\" \/><figcaption class=\"wp-element-caption\">KPMDU-IL-C13C14-2\/3-B (Schwarz)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"224\" height=\"184\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6.png\" alt=\"\" class=\"wp-image-2675\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6.png 224w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-150x123.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-50x41.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-60x49.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-6-100x82.png 100w\" sizes=\"auto, (max-width: 224px) 100vw, 224px\" \/><figcaption class=\"wp-element-caption\">KPMDU-IL-C13C14-2\/3-R (Red)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"215\" height=\"214\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49.png\" alt=\"\" class=\"wp-image-2682\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49.png 215w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-150x150.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-50x50.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-60x60.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-3-49-100x100.png 100w\" sizes=\"auto, (max-width: 215px) 100vw, 215px\" \/><figcaption class=\"wp-element-caption\"><strong>KPMDU-IL-C19C20-2\/3-B <\/strong>(Schwarz)<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"317\" height=\"294\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18.png\" alt=\"\" class=\"wp-image-2680\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18.png 317w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-150x139.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-50x46.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-60x56.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/image2020-11-23_11-4-18-100x93.png 100w\" sizes=\"auto, (max-width: 317px) 100vw, 317px\" \/><figcaption class=\"wp-element-caption\"><strong>KPMDU-IL-C19C20-2\/3-R <\/strong>(Red)<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Integrated residual current measurement (RCM): Testing according to DGUV V3<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the version, the Kentix SmartPDU has an integrated residual current meter (RCM). This allows the plant inspection to be carried out in accordance with DGUV V3. This residual current measurement allows defective power supplies (server power supplies) to be detected at an early stage.  <\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Circuit breaker<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The SmartPDU is equipped with two circuit breakers per segment. All circuit breakers have type C tripping characteristics for increased inrush current. This ensures that in the event of a power failure and subsequent power recovery, the fuses are not immediately tripped by the inrush current when the connected terminal devices are started simultaneously. The inrush current can therefore be 5 times the rated current for a short time. Details of the current curve can be taken from the following diagram.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>I1= Fixed non-tripping current at 30\u00b0C<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>I2= Fixed tripping current at 30\u00b0C<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"601\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-601x1024.png\" alt=\"\" class=\"wp-image-2726\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-601x1024.png 601w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-235x400.png 235w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-88x150.png 88w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-768x1309.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-29x50.png 29w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-901x1536.png 901w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-35x60.png 35w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26-59x100.png 59w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-26.png 934w\" sizes=\"auto, (max-width: 601px) 100vw, 601px\" \/><figcaption class=\"wp-element-caption\">Fuse characteristic with C-characteristic<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Factory settings<\/h2>\n\n<p class=\"wp-block-paragraph\">For initial configuration, use the IP address printed on the device or the address assigned via DHCP in a web browser (HTTPS). Please note the network settings of your connected PC.<\/p>\n\n<p class=\"wp-block-paragraph\">The factory IP addresses at a glance:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-white-background-color has-background\"><tbody><tr><td><strong>SiteManager and AlarmManager<\/strong><\/td><td>192.168.100.222<\/td><\/tr><tr><td><strong>MultiSensor<\/strong><\/td><td>192.168.100.223<\/td><\/tr><tr><td><strong>AccessManager<\/strong><\/td><td>192.168.100.224<\/td><\/tr><tr><td><strong>PowerManager<\/strong><\/td><td>192.168.100.225<\/td><\/tr><tr><td><strong>SmartPDU<\/strong><\/td><td>192.168.100.226<\/td><\/tr><tr><td><strong>Leakage sensor<\/strong><\/td><td>192.168.100.227<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Factory IP addresses, subnet mask: 255.255.255.0<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">For devices with a firmware version lower than 8.x.x, the login data for the preset administrator account are: admin \/ password<\/p>\n\n<h2 class=\"wp-block-heading\">Reset to factory settings<\/h2>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3\"><ol class=\"fa-ul\"><li>Restart the device (disconnect and reconnect the power supply).<\/li><li>The status LED lights up briefly and then goes out.<\/li><li>As soon as the status LED lights up green continuously, press and hold the reset button for 15 seconds until the device emits an acoustic feedback.<\/li><li>The device loads the factory settings and performs a restart.<\/li><li>After approx. 2 minutes, the device can be reached with the factory settings.<\/li><\/ol><style>#heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>All existing settings and data will be irrevocably deleted !<\/strong><br><strong>We recommend regular backup of the system<\/strong>.<\/p>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Assembly instructions<\/h2>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Mounting by means of mounting bracket<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"992\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-1024x992.png\" alt=\"\" class=\"wp-image-10365\" style=\"width:458px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-1024x992.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-400x388.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-150x145.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-768x744.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-50x48.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-1536x1489.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-2048x1985.png 2048w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-60x58.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-2-100x97.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The SmartPDU-40U is mounted vertically in a server rack. Three mounting brackets are supplied with each SmartPDU-40U for mounting. These are used to mount the PDU to a 19 inch rack.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"580\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-580x1024.png\" alt=\"\" class=\"wp-image-10370\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-580x1024.png 580w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-227x400.png 227w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-85x150.png 85w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-768x1355.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-28x50.png 28w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-871x1536.png 871w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-34x60.png 34w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack-57x100.png 57w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1-Rack.png 942w\" sizes=\"auto, (max-width: 580px) 100vw, 580px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Assembly steps<\/h4>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-b748f6fa-2962-4424-a720-faa11bbeaddc\"><ol class=\"fa-ul\"><li>Screw the mounting bracket to the PDU using countersunk screws (hexagon socket, width across flats: 2).<\/li><li>Insert cage nuts (not included in scope of delivery)<\/li><li>Screw PDU to the rack with mounting brackets<\/li><\/ol><style>#heroic-styled-list-b748f6fa-2962-4424-a720-faa11bbeaddc li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"101\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-1024x101.png\" alt=\"\" class=\"wp-image-7831\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-1024x101.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-400x40.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-150x15.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-768x76.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-50x5.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-1536x152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-2048x203.png 2048w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-60x6.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-100x10.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Positions for mounting brackets<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">ATTENTION! Only use the supplied countersunk screws (M3 x 5) to attach the mounting brackets to the SmartPDU. The use of longer screws can damage the SmartPDU.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Mounting by means of quick mounting bracket<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"441\" height=\"222\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18.png\" alt=\"\" class=\"wp-image-2704\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18.png 441w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18-400x201.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18-150x76.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18-50x25.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18-60x30.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-18-100x50.png 100w\" sizes=\"auto, (max-width: 441px) 100vw, 441px\" \/><figcaption class=\"wp-element-caption\">KPMDU-MBR-1<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"426\" height=\"592\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse.png\" alt=\"\" class=\"wp-image-10359\" style=\"width:271px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse.png 426w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse-288x400.png 288w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse-108x150.png 108w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse-36x50.png 36w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse-43x60.png 43w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-1_Masse-72x100.png 72w\" sizes=\"auto, (max-width: 426px) 100vw, 426px\" \/><figcaption class=\"wp-element-caption\">KPMDU-MBR-1 Dimensions  [mm]<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The quick mounting brackets are used to mount the SmartPDU on the rack if a suspension solution is available. The quick mounting bracket is screwed onto the back of the SmartPDU-40U. There are several holes for this purpose. Two quick mounting brackets must always be used to hang the PDU securely. These are not included with the SmartPDU and must be ordered separately (ORDER-CODE: KPMDU-MBR-1).<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-1024x576.png\" alt=\"\" class=\"wp-image-2706\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19-100x56.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-19.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Fastening mounting bracket<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-1024x576.png\" alt=\"\" class=\"wp-image-2712\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21-100x56.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-21.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Assembly steps<\/h4>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e104c460-a22c-4ce8-ba7d-35b52444ccb0\"><ol class=\"fa-ul\"><li>Screw quick mounting bracket to SmartPDU<\/li><li>Hook SmartPDU into the existing suspension solution<\/li><\/ol><style>#heroic-styled-list-e104c460-a22c-4ce8-ba7d-35b52444ccb0 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"139\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-1024x139.png\" alt=\"\" class=\"wp-image-7833\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-1024x139.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-400x54.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-150x20.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-768x104.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-50x7.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-1536x208.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-2048x277.png 2048w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-60x8.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Schnellmontagehalter-100x14.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Positions for quick mounting bracket<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Fastening by means of mounting plates<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"866\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-866x1024.png\" alt=\"\" class=\"wp-image-10363\" style=\"width:428px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-866x1024.png 866w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-338x400.png 338w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-127x150.png 127w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-768x908.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-42x50.png 42w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-1299x1536.png 1299w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-1732x2048.png 1732w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-51x60.png 51w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3-85x100.png 85w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3.png 2008w\" sizes=\"auto, (max-width: 866px) 100vw, 866px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-627x1024.png\" alt=\"\" class=\"wp-image-10361\" style=\"width:261px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-627x1024.png 627w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-245x400.png 245w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-92x150.png 92w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-768x1255.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-31x50.png 31w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-37x60.png 37w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions-61x100.png 61w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Dimensions.png 890w\" sizes=\"auto, (max-width: 627px) 100vw, 627px\" \/><figcaption class=\"wp-element-caption\">KPMDU-MBR-3 Dimensions  [mm]<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">To mount the SmartPDU, mounting plates can be ordered separately, which allow it to be mounted at a 90\u00b0 vertical angle to the mounting bracket (ORDER CODE: KPMDU-MBR-3).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"580\" height=\"1024\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-580x1024.png\" alt=\"\" class=\"wp-image-10372\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-580x1024.png 580w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-227x400.png 227w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-85x150.png 85w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-768x1355.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-28x50.png 28w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-871x1536.png 871w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-34x60.png 34w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack-57x100.png 57w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-MBR-3_Rack.png 942w\" sizes=\"auto, (max-width: 580px) 100vw, 580px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Assembly steps<\/h4>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-30062af9-f2c3-4712-bdb3-7d22ad0a1a34\"><ol class=\"fa-ul\"><li>Screw the mounting plates to the PDU using countersunk screws (hexagon socket, width across flats: 2)<\/li><li>Insert cage nuts (not included in scope of delivery)<\/li><li>Screw the PDU to the rack with mounting plates<\/li><\/ol><style>#heroic-styled-list-30062af9-f2c3-4712-bdb3-7d22ad0a1a34 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"101\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-1024x101.png\" alt=\"\" class=\"wp-image-7831\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-1024x101.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-400x40.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-150x15.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-768x76.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-50x5.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-1536x152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-2048x203.png 2048w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-60x6.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/10\/KPMDU-40U_Montagewinkel-100x10.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Positions for mounting plates<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">ATTENTION! Only use the supplied countersunk screws (M3 x 5) to attach the mounting plates to the SmartPDU. The use of longer screws can damage the SmartPDU.<\/p>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Calibration of the room temperature measurement<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix MultiSensors record all important environmental values of a room, including the room temperature. In order to achieve the most accurate temperature possible and to trigger an alarm if the room temperature exceeds the limit value, we recommend calibrating the temperature measurement at the final installation location. This is especially necessary for sensors with Ethernet (PoE) connection, since a certain intrinsic heat falsifies the measurement. For MultiSensors with radio and battery supply, the influence of the intrinsic heat is not present.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Kentix MultiSensors are not calibrated measuring devices, but alarm devices whose measuring accuracy is completely sufficient for reliable reporting and documentation of limit value violations.<\/p>\n\n<p class=\"wp-block-paragraph\">However, in order to obtain a good measurement result with reproducible measured values in the event of an alarm, the MultiSensor should be calibrated to the respective installation location after installation. To do this, the temperature in the immediate vicinity (approx. 5-10 cm away) of the MultiSensor must be measured comparatively with a room thermometer that is as accurate as possible. If there is a deviation in temperature between the MultiSensor and the thermometer, the temperature value can be corrected. This is done by entering the determined temperature difference between the MultiSensor and the room thermometer as a correction offset in the KentixONE software. The correction also has a direct influence on the measurement of the relative humidity and on the dew point calculation of the MultiSensor.<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Step<\/th><th>Note<\/th><\/tr><\/thead><tbody><tr><td>Install MultiSensor at the destination.<\/td><td>The position and orientation of the sensor should not be changed afterwards.<br\/>Please note the following:<br\/>&#8211; Mount with the X air opening facing downwards<br\/>&#8211; Do not mount in the air flow<br\/>&#8211; Ventilation vents of the sensor must be unobstructed<\/td><\/tr><tr><td>Perform configuration of the MultiSensor with Kentix ONE.<\/td><td><\/td><\/tr><tr><td>At the earliest 30 minutes after commissioning<br\/>, adjust the temperature of the MultiSensor to the room temperature.<\/td><td>To do this, measure the temperature with an external reference thermometer in the immediate vicinity, approx. 5-10 cm from the MultiSensor. It should be noted that this thermometer also acclimatizes to the room and displays the correct room temperature only after a few minutes.<\/td><\/tr><tr><td>If a difference between the MultiSensor and the thermometer is detected, this can be entered in the &#8220;Offset&#8221; field in the KentixONE configuration of the MultiSensor. After saving, the sensor then provides the corrected measured value.<\/td><td>The offset can only be specified by whole degrees, i.e. without decimal places.<br\/>This results in an accuracy for the temperature of +\/- 0.5 degrees.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Configuration with KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">The device is configured via the web browser in KentixONE. The device must be accessible to the central KentixONE instance on the network side. Depending on the device type, a communication key and the IP address or DHCP name of the central KentixONE instance must also be set on the device (MultiSensors, AccessManager, SmartPDU). IP cameras or IO modules, on the other hand, can be integrated directly into KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software can be found in the <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> section and the associated documentation.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Before starting the configuration, make sure that the software on all network-compatible Kentix devices is up-to-date. The version status must match on all devices.<br><strong>You can perform a software update for your KentixONE main instance and all connected satellites at any time via &#8220;System &#8211; Update&#8221;.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATA SHEET SmartPDU-40U Overview The SmartPDU is optimized for power supply of end devices in data and network cabinets with simultaneous power monitoring, consumption data logging and environmental monitoring and is typically mounted in a 19 inch rack. With the integrated PowerManager and MultiSensor, up to 100 SmartPDUs can be&#8230;<\/p>\n","protected":false},"author":4,"featured_media":7197,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[128],"ht-kb-tag":[],"class_list":["post-4077","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartpdu-vertically-horizontally"],"custom_fields":{"kentix_order_code":["KPMDU-RC-xxxxC13C19-x-xx"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartpdu-vertically-horizontally","name":"SmartPDU - Vertically\/horizontally","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/KPMDU-RC-4800C13C19-2_1920x1920-150x13.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4077"}],"version-history":[{"count":30,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4077\/revisions"}],"predecessor-version":[{"id":10375,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4077\/revisions\/10375"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/7197"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4077"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4077"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}