{"id":4074,"date":"2023-02-27T16:20:52","date_gmt":"2023-02-27T15:20:52","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/wall-reader-doorlock-wa3-outdoor-operating-instructions\/"},"modified":"2026-02-04T16:12:07","modified_gmt":"2026-02-04T15:12:07","slug":"wall-reader-doorlock-wa3-outdoor-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/wall-reader-doorlock-wa3-outdoor-operating-instructions\/","title":{"rendered":"DoorLock-WA3-OUTDOOR wall reader &#8211; MANUAL"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Replaced by: KXC-WA3-V2-OUTDOOR-IP1, KXC-WA3-V2-OUTDOOR-IP<\/p>\n\n<pre class=\"wp-block-preformatted\"><a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-kxc-wa3-outdoor-art-kxc-wa3-ip2-outdoor-data-sheet\/\" target=\"_blank\">DATASHEET KXC-WA3-OUTDOOR-IP1<\/a><a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-kxc-wa3-outdoor-art-kxc-wa3-ip2-outdoor-data-sheet\/\" target=\"_blank\">,<\/a> <a rel=\"noreferrer noopener\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-wa2-art-kxc-wa2-ip2-data-sheet\/\" target=\"_blank\">KXC-WA3-OUTDOOR-IP<\/a><\/pre>\n\n<p class=\"wp-block-paragraph\">The IP wall readers enable contactless unlocking of doors with an RFID chip and\/or PIN code as two-factor authentication for models with an integrated keypad. The IP wall readers always consist of the actual wall reader and the Kentix <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">SmartRelay<\/a>. The wall readers are connected using a <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">SmartRelay<\/a> and can then be connected to an AccessManager (KXP-2-RS) via the Manager\/Satellite mode. The wall reader is available in various designs for indoor\/outdoor, surface-mounted\/flush-mounted or for installation in intercom systems.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">A Kentix AccessManager for cable readers (KXP-2-RS) is required to operate wall readers. Information about the relay and<strong> circuit diagrams including examples<\/strong> can be found here:&nbsp;<a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">Kentix SmartRelay (KXP-2-RS)<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h4 class=\"wp-block-heading\">WA3 Outdoor View Front<\/h4>\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135.png\" alt=\"\" class=\"wp-image-2459\" style=\"width:665px;height:499px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-135-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">WA3 Outdoor View Front<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-2edb7b87-216a-4d2c-991a-ac3ed18a53dc\"><ol class=\"fa-ul\"><li>Integrated RFID reader, the entire surface serves as a reading surface<\/li><li>Housing screws, behind the black covers on both sides<\/li><li>Cable input, the cables are fed into the device here<\/li><\/ol><style>#heroic-styled-list-2edb7b87-216a-4d2c-991a-ac3ed18a53dc li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h4 class=\"wp-block-heading\">Functional elements front<\/h4>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-689e3259-0a5b-4949-9777-ea9d6414c11d\"><ol class=\"fa-ul\"><li>Integrated RFID reader, the entire surface serves as a reading surface<\/li><\/ol><style>#heroic-styled-list-689e3259-0a5b-4949-9777-ea9d6414c11d li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">WA3 interior view<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-1024x768.png\" alt=\"\" class=\"wp-image-2463\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-137.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-0df978b3-2d9a-4dcb-aad8-dc4b8a5a79c3\"><ol class=\"fa-ul\"><li>Terminal block 1, see wiring diagram<\/li><li>DIP switch for configuring the address<\/li><\/ol><style>#heroic-styled-list-0df978b3-2d9a-4dcb-aad8-dc4b8a5a79c3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h4 class=\"wp-block-heading\">Terminal assignment WA3 Outdoor<\/h4>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Clamp<\/th><th>Function<\/th><\/tr><tr><td>1<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td>RS485 Data &#8220;A&#8221;<\/td><\/tr><tr><td>7<\/td><td>RS485 Data &#8220;B&#8221;<\/td><\/tr><tr><td>8<\/td><td>8-30 V\/DC<\/td><\/tr><tr><td>9  <\/td><td>GND<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA3 Outdoor Terminal assignment<\/figcaption><\/figure>\n\n<h4 class=\"wp-block-heading\">DIP switch WA3 Outdoor and WA2<\/h4>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>DIP switch<\/th><th>Function<\/th><\/tr><tr><td><strong>1<\/strong><\/td><td>Address 1 (1=ON, 2=OFF)<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Address 2 (1=OFF, 2=ON)<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>&#8211;<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>&#8211;<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>Baud rate (5=ON)<\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>&#8211;<\/td><\/tr><tr><td><strong>7<\/strong><\/td><td>&#8211;<\/td><\/tr><tr><td><strong>8<\/strong><\/td><td>Terminating resistor*<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA3 Outdoor DIP switch<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">*The terminating resistor is required from a cable length of 500m.<\/p>\n\n<h2 class=\"wp-block-heading\">Connection example<\/h2>\n\n<h3 class=\"wp-block-heading\">One or two wall readers with door contacts and external door openers<\/h3>\n\n<p class=\"wp-block-paragraph\">Terminal 2 on the AccessManager provides communication via the data bus and the supply of operating voltage for the wall readers. (terminals 3-6). Terminal 2 serves as a common potential for the power supply of door openers with the PoE supply voltage of the AccessManager.<\/p>\n\n<p class=\"wp-block-paragraph\">Terminal 1 is used for connection of potential-free contacts (&#8220;door contacts&#8221;, terminals 1-4) and switching of door openers by relay 2 (5-6) and relay 1 (7-8). Relay 1 and 2 switch terminal 1 to terminal 2 to common potential (terminal2, terminal 2).<\/p>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"853\" height=\"640\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited.jpeg\" alt=\"\" class=\"wp-image-5597\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited.jpeg 853w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/06\/wiring_schema_WA2-IPXWA3-Outdoor-V2.001-edited-100x75.jpeg 100w\" sizes=\"auto, (max-width: 853px) 100vw, 853px\" \/><figcaption class=\"wp-element-caption\">One or two WallReaders on one AccessManager<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Commissioning two wall readers on one AccessManager<\/strong><br>If two WallReaders are to be operated with one AccessManager, proceed as follows for commissioning:<br>Connect the first WallReader to the AccessManager. Add it in the main device with &#8220;DoorLock (IP)&#8221;. Only when the first WallReader has been put into operation, they connect the second device and add it as well.<\/p>\n\n<h2 class=\"wp-block-heading\">User and access management<\/h2>\n\n<p class=\"wp-block-paragraph\">The administration of users and access rights is done on the main device of the installation with KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software is available in the <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a> section.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Replaced by: KXC-WA3-V2-OUTDOOR-IP1, KXC-WA3-V2-OUTDOOR-IP DATASHEET KXC-WA3-OUTDOOR-IP1, KXC-WA3-OUTDOOR-IP The IP wall readers enable contactless unlocking of doors with an RFID chip and\/or PIN code as two-factor authentication for models with an integrated keypad. The IP wall readers always consist of the actual wall reader and the Kentix SmartRelay. The wall readers&#8230;<\/p>\n","protected":false},"author":4,"featured_media":363,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[118],"ht-kb-tag":[],"class_list":["post-4074","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-product-archive"],"custom_fields":{"kentix_order_code":[" KXC-WA3-OUTDOOR-IP1, KXC-WA3-OUTDOOR-IP"],"kentix_legacy_product":["1"]},"categories":[{"slug":"smartaccess-product-archive","name":"SmartAccess product archive","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KXC-WA1-OUTDOOR-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4074"}],"version-history":[{"count":16,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4074\/revisions"}],"predecessor-version":[{"id":12649,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4074\/revisions\/12649"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/363"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4074"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4074"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}