{"id":4059,"date":"2023-02-28T12:38:37","date_gmt":"2023-02-28T11:38:37","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/doorlock-wa6-ip-frame-reader-operating-instructions\/"},"modified":"2023-12-21T11:19:09","modified_gmt":"2023-12-21T10:19:09","slug":"doorlock-wa6-ip-frame-reader-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-wa6-ip-frame-reader-operating-instructions\/","title":{"rendered":"Wall reader (bus) DoorLock-WA6 &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-wa6-art-kxc-wa6-ip2-data-sheet\/\" target=\"_blank\" rel=\"noreferrer noopener\">DATASHEET KXC-WA6-IPx<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix IP wall readers enable contactless control of doors with a MIFARE\u00ae DESFire\u00ae RFID chip. All electronics are located on a compact unit. Due to its compact design, the reader is particularly suitable for use with narrow metal profiles. The setup always consists of the actual wall reader and the connected Kentix <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager<\/a>. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes\/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">A Kentix AccessManager for Cable Reader (KXP-2-RS) is required to operate the frame reader. Information about the relay and<strong> circuit diagrams including examples<\/strong> can be found here: <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager (Bus)<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h3 class=\"wp-block-heading\">KXC-WA6-IP Front panel<\/h3>\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155.png\" alt=\"\" class=\"wp-image-2523\" style=\"width:600px;height:450px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155.png 800w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-155-100x75.png 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">WA6-IP Front view<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">DIP switch rear side<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"165\" height=\"168\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-156.png\" alt=\"\" class=\"wp-image-2525\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-156.png 165w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-156-147x150.png 147w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-156-50x50.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-156-60x60.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-156-98x100.png 98w\" sizes=\"auto, (max-width: 165px) 100vw, 165px\" \/><figcaption class=\"wp-element-caption\">WA6-IP DIP switch<\/figcaption><\/figure>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>DIP switch  <\/th><th>Function<\/th><\/tr><tr><td>1<\/td><td>Address 1<strong>(1=ON, 2=OFF<\/strong>)<\/td><\/tr><tr><td>2<\/td><td>Address 2<strong>(1=OFF, 2=ON<\/strong>)<\/td><\/tr><tr><td>3<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td>Baud rate<strong>(ON<\/strong>)<\/td><\/tr><tr><td>6<\/td><td>Terminating resistor<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA6-IP Table DIP switches<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Terminal assignment<\/h3>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Clamp<\/th><th>Function<\/th><\/tr><tr><td><strong>1<\/strong><\/td><td>10-30V\/DC, max. 3,5VA<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>GND<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>RS485 Data &#8220;A<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>RS485 Data<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA6-IP Terminal assignment<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Wiring<\/h3>\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157.png\" alt=\"\" class=\"wp-image-2527\" style=\"width:658px;height:493px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-157-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">WA6-IP circuitry  <\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">User and access management<\/h2>\n\n<p class=\"wp-block-paragraph\">The administration of users and access rights is done on the main device of the installation with KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software is available in the <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a> section.<\/p>\n\n<h2 class=\"wp-block-heading\">Signaling<\/h2>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td><strong>Signal and explanation<\/strong><\/td><\/tr><tr><td>Wall reader is offline<\/td><td>LED flashes magenta<\/td><\/tr><tr><td>Access granted<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Access denied<\/td><td>short tone, LED flashes red<\/td><\/tr><tr><td>Zone is armed<\/td><td>3 long tones, simultaneously LED flashes 3x red<\/td><\/tr><tr><td>Zone is armed<\/td><td>LED flashes red regularly<\/td><\/tr><tr><td>Arming not possible<\/td><td>long tone, LED flashes red<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table signaling<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>DATASHEET KXC-WA6-IPx Overview Kentix IP wall readers enable contactless control of doors with a MIFARE\u00ae DESFire\u00ae RFID chip. All electronics are located on a compact unit. Due to its compact design, the reader is particularly suitable for use with narrow metal profiles. The setup always consists of the actual wall&#8230;<\/p>\n","protected":false},"author":4,"featured_media":2522,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[157],"ht-kb-tag":[],"class_list":["post-4059","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-en"],"custom_fields":{"kentix_order_code":["KXC-WA6-IP1,KXC-WA6-IP2"],"kentix_skill_level":["2"]},"categories":[{"slug":"smartaccess-bus-en","name":"SmartAccess Bus","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-154-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4059"}],"version-history":[{"count":12,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4059\/revisions"}],"predecessor-version":[{"id":8510,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4059\/revisions\/8510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/2522"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4059"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4059"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}