{"id":4041,"date":"2023-03-03T08:36:47","date_gmt":"2023-03-03T07:36:47","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/powermanager-operating-instructions\/"},"modified":"2026-01-06T08:44:48","modified_gmt":"2026-01-06T07:44:48","slug":"powermanager-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/powermanager-operating-instructions\/","title":{"rendered":"PowerManager &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/powermanager-art-kpm-100-data-sheet\/\">DATASHEET KPM-100<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">KentixONE Operating mode<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">SiteManager Operation<\/th><th class=\"has-text-align-center\" data-align=\"center\">Stand-alone operation<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><td class=\"has-text-align-center\" data-align=\"center\"><i class=\"fas fa-check\"><\/i><\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><a href=\"https:\/\/docs.kentix.com\/en\/?post_type=ht_kb&amp;p=6835\">Further information on the operating mode<\/a><\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">The Kentix PowerManager is the management unit for Kentix SmartPDU components and energy consumption meters with an RS-485 interface. The PowerManager is network-compatible and is supplied with voltage via Power over Ethernet (PoE).<\/p>\n\n<p class=\"wp-block-paragraph\">The PowerManager can be operated as the main device (operating mode: Main Device) or in a network (operating mode: Satellite Device) with other PowerManagers. The KentixONE software is already integrated via the integrated web server (HTTPS). The configuration is done via web browser and depending on the operating mode (operating mode: Main Device) locally on the PowerManager itself or on a central instance like the SiteManager or AlarmManager (operating mode: Satellite Device).<\/p>\n\n<p class=\"wp-block-paragraph\">The PowerManager can be mounted on a standard DIN rail or alternatively in a 60mm switch box.<\/p>\n\n<p class=\"wp-block-paragraph\">The PowerManager is the central component of the solution. Here the SmartMeter or ModBus meters are connected via RS485 or LAN. The PowerManager is connected to the network via a PoE-capable switch.<\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n<h2 class=\"wp-block-heading\">Connection and operating elements<\/h2>\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"576\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29.png\" alt=\"\" class=\"wp-image-3943\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/grafik-29-100x75.png 100w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><figcaption class=\"wp-element-caption\">PowerManager front view<\/figcaption><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-90d27c01-5e36-4284-919f-415aaf15245b\"><ol class=\"fa-ul\"><li>Terminal block 1 (terminal 1-8, IO terminal with relay 1+2, digital input 1+2)<\/li><li>Terminal block 2 (terminal 1-6, BUS-POWER-OUT terminal)<\/li><li>Ethernet port with PoE power supply, Class 3 (12.95W)<\/li><li>Jumper for switching the logic for relay output 1+2 (NC, NO)<\/li><\/ol><style>#heroic-styled-list-90d27c01-5e36-4284-919f-415aaf15245b li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">ATTENTION! <strong>Terminals 1-4<\/strong> on <strong>terminal block 2<\/strong> supply a voltage of 24VDC (integrated PoE splitter) and are not intended for powering the module. Applying an external power supply may destroy the module. The power supply of the AcessManager is exclusively via PoE.<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Terminal block 1<\/th><th>Function connection<\/th><\/tr><tr><td>1<\/td><td>Digital input DI 1 (For potential-free wiring, e.g. door contact)<\/td><\/tr><tr><td>2<\/td><td>Digital input DI 1 (For potential-free wiring)<\/td><\/tr><tr><td>3<\/td><td>Digital input DI 2 (For potential-free wiring)<\/td><\/tr><tr><td>4<\/td><td>Digital input DI 2 (For potential-free wiring)<\/td><\/tr><tr><td>5<\/td><td>Relay 2 NO\/NC (Default=NO)<\/td><\/tr><tr><td>6<\/td><td>Relay 2 COM (relay power max. 60VDC\/1A)<\/td><\/tr><tr><td>7<\/td><td>Relay 1 NO\/NC (Default=NO)<\/td><\/tr><tr><td>8<\/td><td>Relay 1 COM (relay power max. 60VDC\/1A)<\/td><\/tr><\/thead><\/table><\/figure>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Terminal block 2<\/th><th>Function connection<\/th><\/tr><tr><td>1<\/td><td>(+) 24VDC (power supply door opener, max. 0.5A)<\/td><\/tr><tr><td>2<\/td><td>(-) GND (power supply door opener, max. 0.5A)<\/td><\/tr><tr><td>3<\/td><td>(+) 24VDC (power supply RFID reader)<\/td><\/tr><tr><td>4<\/td><td>(-) GND (power supply RFID reader)<\/td><\/tr><tr><td>5<\/td><td>BUS-B (communication line to RFID reader)<\/td><\/tr><tr><td>6<\/td><td>BUS-A (communication line to RFID reader)<\/td><\/tr><\/thead><\/table><\/figure>\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"927\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-1024x927.jpg\" alt=\"\" class=\"wp-image-3715\" style=\"aspect-ratio:1.104640723982431;width:654px;height:auto\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-1024x927.jpg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-400x362.jpg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-150x136.jpg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-768x695.jpg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-50x45.jpg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-60x54.jpg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01-100x91.jpg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/03\/SmartRelais-Modul_seitlich_01.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Side view<\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Factory settings<\/h2>\n\n<p class=\"wp-block-paragraph\">For initial configuration, use the IP address printed on the device or the address assigned via DHCP in a web browser (HTTPS). Please note the network settings of your connected PC.<\/p>\n\n<p class=\"wp-block-paragraph\">The factory IP addresses at a glance:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-white-background-color has-background\"><tbody><tr><td><strong>SiteManager and AlarmManager<\/strong><\/td><td>192.168.100.222<\/td><\/tr><tr><td><strong>MultiSensor<\/strong><\/td><td>192.168.100.223<\/td><\/tr><tr><td><strong>AccessManager<\/strong><\/td><td>192.168.100.224<\/td><\/tr><tr><td><strong>PowerManager<\/strong><\/td><td>192.168.100.225<\/td><\/tr><tr><td><strong>SmartPDU<\/strong><\/td><td>192.168.100.226<\/td><\/tr><tr><td><strong>Leakage sensor<\/strong><\/td><td>192.168.100.227<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Factory IP addresses, subnet mask: 255.255.255.0<\/figcaption><\/figure>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">For devices with a firmware version lower than 8.x.x, the login data for the preset administrator account are: admin \/ password<\/p>\n\n<h2 class=\"wp-block-heading\">Reset to factory settings<\/h2>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3\"><ol class=\"fa-ul\"><li>Restart the device (disconnect and reconnect the power supply).<\/li><li>The status LED lights up briefly and then goes out.<\/li><li>As soon as the status LED lights up green continuously, press and hold the reset button for 15 seconds until the device emits an acoustic feedback.<\/li><li>The device loads the factory settings and performs a restart.<\/li><li>After approx. 2 minutes, the device can be reached with the factory settings.<\/li><\/ol><style>#heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>All existing settings and data will be irrevocably deleted !<\/strong><br><strong>We recommend regular backup of the system<\/strong>.<\/p>\n\n<h2 class=\"wp-block-heading\">Configuration with KentixONE<\/h2>\n\n<p class=\"wp-block-paragraph\">The device is configured via the web browser in KentixONE. The device must be accessible to the central KentixONE instance on the network side. Depending on the device type, a communication key and the IP address or DHCP name of the central KentixONE instance must also be set on the device (MultiSensors, AccessManager, SmartPDU). IP cameras or IO modules, on the other hand, can be integrated directly into KentixONE.   <\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software can be found in the <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> section and the associated documentation.<\/p>\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Before starting the configuration, make sure that the software on all network-compatible Kentix devices is up-to-date. The version status must match on all devices.<br><strong>You can perform a software update for your KentixONE main instance and all connected satellites at any time via &#8220;System &#8211; Update&#8221;.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>DATASHEET KPM-100 Overview The Kentix PowerManager is the management unit for Kentix SmartPDU components and energy consumption meters with an RS-485 interface. The PowerManager is network-compatible and is supplied with voltage via Power over Ethernet (PoE). The PowerManager can be operated as the main device (operating mode: Main Device) or&#8230;<\/p>\n","protected":false},"author":4,"featured_media":88,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[128],"ht-kb-tag":[],"class_list":["post-4041","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartpdu-vertically-horizontally"],"custom_fields":{"kentix_order_code":["KPM-100"],"kentix_skill_level":["3"]},"categories":[{"slug":"smartpdu-vertically-horizontally","name":"SmartPDU - Vertically\/horizontally","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/relaismodule_1920x1920-e1678900770465-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4041"}],"version-history":[{"count":10,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4041\/revisions"}],"predecessor-version":[{"id":12421,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4041\/revisions\/12421"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/88"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4041"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4041"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}