{"id":4040,"date":"2023-03-15T13:32:13","date_gmt":"2023-03-15T12:32:13","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/wall-reader-doorlock-wa3-operating-instructions\/"},"modified":"2025-06-25T15:37:28","modified_gmt":"2025-06-25T13:37:28","slug":"wall-reader-doorlock-wa3-operating-instructions","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/wall-reader-doorlock-wa3-operating-instructions\/","title":{"rendered":"DoorLock-WA3 wall reader (bus) &#8211; MANUAL"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a data-type=\"ht_kb\" data-id=\"424\" href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/doorlock-wa3-art-kxc-wa3-ip2-data-sheet\/\">Datasheet KXC-WA3-IPx<\/a><\/pre>\n\n<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n<p class=\"wp-block-paragraph\">Kentix IP wall readers enable contactless control of doors with a MIFARE\u00ae DESFire\u00ae RFID chip. The setup always consists of the actual wall reader and the connected Kentix <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">AccessManager<\/a>. The wall reader is connected to the AccessManager via a 4-wire connection. The AccessManager itself connects directly to a Power over Ethernet (PoE) capable network switch. To control electric strikes\/motor locks, the SmartRelay offers two relay outputs and, depending on the power class of the strikes, an integrated PoE splitter with 24VDC output.<\/p>\n\n<h2 class=\"wp-block-heading\">Safety instructions<\/h2>\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation and commissioning may only be carried out by trained specialist personnel in accordance with the instructions.<br>No modifications of any kind, other than those described in an appropriate manual, are permitted to Kentix GmbH products.<br>Certain levels of protection must be provided when installing Kentix equipment.<br>Observe the relevant regulations for installations in the respective environment.<br>Only operate the products within the defined temperature range.<br>The instructions should be passed on to the user by the person carrying out the installation.<br>Kentix accepts no liability for damage to the equipment or components resulting from incorrect installation. No liability is accepted for incorrectly programmed units.<br>Kentix shall not be liable in the event of malfunctions, damage to property or other damage.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Use of the products, transport and storage<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Protect the device during transport, storage and operation from<br>Protect moisture, dirt and damage.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Battery powered products<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Do not use products in potentially explosive atmospheres.<br>Only operate the products within the defined temperature range.<br>Installation and battery replacement may only be carried out by trained personnel in accordance with the instructions.<br>Do not charge, short circuit, open or heat batteries.<br>When inserting the batteries, pay attention to the correct polarity.<br>The devices must always be operated with the batteries intended for the product.<br>When changing batteries, always replace all batteries.<br>Dispose of old or used batteries properly.<br>Keep batteries out of the reach of children.  <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Maintenance<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix devices must be checked for functionality as part of annual maintenance.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Disposal<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Electrical appliances and batteries must be disposed of separately from household waste.<br><\/div><\/div><\/div><\/div>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Controls<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">DoorLock-WA3-V1 Front view<\/h4>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-1024x768.png\" alt=\"\" class=\"wp-image-2454\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-133.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">WA3 Front view<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-f199d07f-4774-4318-9218-3ad158a1293a\"><ol class=\"fa-ul\"><li>Touch keyboard with illuminated keypad and &#8220;arm alarm&#8221; function key<\/li><li>Touch keyboard with illuminated keypad and &#8220;disarm alarm&#8221; function key<\/li><li>Integrated RFID reader, the entire surface serves as a reading surface.<\/li><\/ol><style>#heroic-styled-list-f199d07f-4774-4318-9218-3ad158a1293a li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">The keypad can be deactivated in the configuration screen of the wall reader (from KentixONE version 8.4.3). This can be useful if an alarm group is only to be armed or disarmed on a specific wall reader using an RFID token. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">DoorLock-WA3-V1 Rear view<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-1024x768.png\" alt=\"\" class=\"wp-image-2457\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-1024x768.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-1536x1152.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134-100x75.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-134.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-04062d1d-4834-442f-80eb-c50ef7ef0e6c\"><ol class=\"fa-ul\"><li>Connection terminals, assignment see table<\/li><li>DIP switch for configuring the address<\/li><\/ol><style>#heroic-styled-list-04062d1d-4834-442f-80eb-c50ef7ef0e6c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Terminal assignment wall reader WA3-V1<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th><strong>Clamp<\/strong><\/th><th>Function<\/th><th>Connection to <strong>AccessManager<\/strong> (SmartRelay)<\/th><\/tr><\/thead><tbody><tr><td><strong>1<\/strong><\/td><td>RS485 Data &#8220;A<\/td><td>Terminal Block 2, Terminal 6 (A)<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>RS485 Data &#8220;B<\/td><td>Terminal Block 2, Terminal 5 (B)<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>&#8211;<\/td><td><\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>&#8211;<\/td><td><\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>&#8211;<\/td><td><\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>&#8211;<\/td><td><\/td><\/tr><tr><td><strong>7<\/strong><\/td><td>  GND<\/td><td>Terminal Block-2, Terminal 4 ( &#8211; )<\/td><\/tr><tr><td><strong>8<\/strong><\/td><td>  12-24V\/DC<\/td><td>Terminal Block-2, Terminal 3 (+)<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA3 Terminal assignment<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch.png\" alt=\"\" class=\"wp-image-9645\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/04\/KXC-WA3_DIP_switch-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e33a9bcc-b720-432c-b6d2-ac837b8fcd4b\"><ol class=\"fa-ul\"><li>DIP switch for configuring the address<\/li><\/ol><style>#heroic-styled-list-e33a9bcc-b720-432c-b6d2-ac837b8fcd4b li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">DIP switch wall reader WA3<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>DIP switch<\/th><th>Function<\/th><\/tr><tr><td><strong>1<\/strong><\/td><td>Address bit 0 (address 1: ON; address 2: OFF)<\/td><\/tr><tr><td><strong>2<\/strong><\/td><td>Address bit 1 (address 1: OFF; address 2: ON)<\/td><\/tr><tr><td><strong>3<\/strong><\/td><td>Address bit 2 (OFF)<\/td><\/tr><tr><td><strong>4<\/strong><\/td><td>Address bit 3 (OFF)<\/td><\/tr><tr><td><strong>5<\/strong><\/td><td>Baud rate (ON)<\/td><\/tr><tr><td><strong>6<\/strong><\/td><td>Terminating resistor*<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">KXC-WA3 DIP switch<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">*The terminating resistor is required for longer cable lengths (&gt; 100m). As cable we recommend telecommunication installation cable e.g. TYPE: J-Y(ST)Y 2x2x0.8mm<sup>2<\/sup>.<\/p>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Connection examples<\/h2>\n\n<h3 class=\"wp-block-heading\">Two wall readers with door contacts and external door openers<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1.png\" alt=\"\" class=\"wp-image-9513\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_1-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Wiring diagram AccessManager KXP-2-RS with 2x wall reader, 2x door opener, 2x door contact<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Two wall readers with door contacts and external power supply for the electric strikes<\/h3>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2.png\" alt=\"\" class=\"wp-image-9515\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_wiring_schema_2-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Wiring diagram AccessManager KXP-2-RS with 2x wall readers and external power supply for the door openers<\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">User and access management<\/h2>\n\n<p class=\"wp-block-paragraph\">The administration of users and access rights is done on the main device of the installation with KentixOne.<\/p>\n\n<p class=\"wp-block-paragraph\">All information about the software is available in the <a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/kentixone-erste-schritte\/\" data-type=\"ht_kb\" data-id=\"874\">KentixONE<\/a> section.<\/p>\n\n<h2 class=\"wp-block-heading\">Assembly and disassembly<\/h2>\n\n<h3 class=\"wp-block-heading\">Flush-mounted variant<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-1024x576.png\" alt=\"\" class=\"wp-image-9509\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP-100x56.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_UP.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-fc9300ec-e2cb-40bc-ad65-0ab89d9721f0\"><ol class=\"fa-ul\"><li>Mounting bracket for flush-mounted application (included in scope of delivery)<\/li><li>Wall reader KXC-WA3<\/li><li>Locking strip<\/li><\/ol><style>#heroic-styled-list-fc9300ec-e2cb-40bc-ad65-0ab89d9721f0 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Surface-mounted version<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-1024x576.png\" alt=\"\" class=\"wp-image-9507\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP-100x56.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Montage_AP.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-645a1762-8bc7-4849-a0ca-5d01cce72286\"><ol class=\"fa-ul\"><li>Mounting bracket for surface-mounted applications KXC-WA3-SMC<\/li><li>Wall reader KXC-WA3<\/li><li>Locking strip<\/li><\/ol><style>#heroic-styled-list-645a1762-8bc7-4849-a0ca-5d01cce72286 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h3 class=\"wp-block-heading\">Dismantling<\/h3>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-1024x576.png\" alt=\"\" class=\"wp-image-9511\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-1024x576.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-400x225.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-150x84.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-768x432.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-50x28.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-1536x864.png 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-60x34.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage-100x56.png 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2024\/03\/KXC-WA3_Demontage.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-076368bb-6f7b-4e22-9554-7750755d40c3\"><ol class=\"fa-ul\"><li>Insert the screwdriver into the unlocking openings and unlock the lock. Pull out the locking bar.<\/li><li>Push the wall reader upwards and lift it forwards.<\/li><\/ol><style>#heroic-styled-list-076368bb-6f7b-4e22-9554-7750755d40c3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n<h2 class=\"wp-block-heading\">Signaling<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Function<\/th><th>Signal and explanation<\/th><\/tr><\/thead><tbody><tr><td>Wall reader is offline<\/td><td>LED flashes orange<\/td><\/tr><tr><td>Pine input<\/td><td>LED flashes blue<\/td><\/tr><tr><td>Access granted<\/td><td>short tone, LED flashes green<\/td><\/tr><tr><td>Door is opened by time profiles<\/td><td>LED lights up permanently green<\/td><\/tr><tr><td>Access denied<\/td><td>3x short beep, LED flashes red<\/td><\/tr><tr><td>Zone is armed<\/td><td>3 long tones, simultaneously LED flashes 3x red<\/td><\/tr><tr><td>Arming not possible<\/td><td>long tone, LED flashes red<\/td><\/tr><tr><td>Zone is armed<\/td><td>LED flashes red<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Table signaling<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Datasheet KXC-WA3-IPx Overview Controls DoorLock-WA3-V1 Front view DoorLock-WA3-V1 Rear view Terminal assignment wall reader WA3-V1 Clamp Function Connection to AccessManager (SmartRelay) 1 RS485 Data &#8220;A Terminal Block 2, Terminal 6 (A) 2 RS485 Data &#8220;B Terminal Block 2, Terminal 5 (B) 3 &#8211; 4 &#8211; 5 &#8211; 6 &#8211; 7&#8230;<\/p>\n","protected":false},"author":2,"featured_media":393,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[157],"ht-kb-tag":[],"class_list":["post-4040","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-bus-en"],"custom_fields":{"kentix_order_code":["KXC-WA3-IP1, KXC-WA3-IP2"]},"categories":[{"slug":"smartaccess-bus-en","name":"SmartAccess Bus","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KXC-WA3-IP2-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4040","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=4040"}],"version-history":[{"count":19,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4040\/revisions"}],"predecessor-version":[{"id":11132,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/4040\/revisions\/11132"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/393"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=4040"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=4040"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=4040"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}