{"id":2107,"date":"2023-01-08T20:45:13","date_gmt":"2023-01-08T19:45:13","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/i-o-module-with-8-analog-inputs-art-kio7017-data-sheet\/"},"modified":"2025-10-10T10:39:45","modified_gmt":"2025-10-10T08:39:45","slug":"i-o-module-with-8-analog-inputs-art-kio7017-data-sheet","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-8-analog-inputs-art-kio7017-data-sheet\/","title":{"rendered":"I\/O module with 8 analog inputs &#8211; DATASHEET"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td>Expansion module for up to 8 external analog inputs. Communication is via Ethernet, so the module can be mounted anywhere. The configuration is done in the KentixONE software interface. The module offers easy IP configuration and testing of the inputs without additional software via the integrated web server.<\/td><\/tr><tr><td>Connection possibility<\/td><td>AlarmManager or SiteManager<\/td><\/tr><tr><td><strong>Configuration<\/strong><\/td><td>Integr. Web server (HTTP)<br>Default IP: 192.168.255.1 (Admin\/Admin)<\/td><\/tr><tr><td><strong>Protocols<\/strong><\/td><td>KAM-IO communication via IP port: 502 (default)<\/td><\/tr><tr><td><strong>Security<\/strong><\/td><td>ID, password and IP filter<\/td><\/tr><tr><td><strong>Connection terminals<\/strong><\/td><td>Plug-in screw terminals for cables up to 1mm\u00b2<\/td><\/tr><tr><td><strong>Enter<\/strong><strong>\u00e4<\/strong><strong>nge<\/strong><\/td><td>8x differential analog inputs with 16-bit resolution<br>Sampling rate 10Hz and voltage input 0-10V or current input 4-20mA, accuracy 0.1%.<\/td><\/tr><tr><td><strong>External sensors<\/strong><\/td><td>Analog sensors with:Voltage output 0-10V (default)<br>Current output 4-20mA (Must be activated by jumper)<br>Digital outputs: Open Collector (max. 700mA, 5-50 VDC)<\/td><\/tr><tr><td><strong>Outputs<\/strong><\/td><td>4 digital outputs &#8211; not usable<\/td><\/tr><tr><td><strong>Insulation<\/strong><\/td><td>Ethernet 1.5kVDC, I\/O 3.7kVrms<\/td><\/tr><tr><td><strong>Environment<\/strong><\/td><td>Operating temperature 0\u00b0C to +45\u00b0C, Rel. Humidity 10-90%<\/td><\/tr><tr><td><strong>Network<\/strong><\/td><td>LAN 10\/100 Base-TX<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td>PoE (Class 1) or external power supply 12-30VDC, 4.3Watt<\/td><\/tr><tr><td>Housing<\/td><td>72 x 123 x 35 mm (DIN rail mounting)<\/td><\/tr><tr><td><strong>Scope of delivery<\/strong><\/td><td>KIO7017, 3m patch cable, power connection cable, manual<\/td><\/tr><tr><td><strong>Approval<\/strong><\/td><td>CE<\/td><\/tr><tr><td>Accessories<\/td><td>Power supply unit or PoE injector if no PoE supply is available.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Terminal assignment<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17.jpg\" alt=\"\" class=\"wp-image-729\" width=\"744\" height=\"638\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17.jpg 992w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17-400x343.jpg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17-150x129.jpg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17-768x658.jpg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17-50x43.jpg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17-60x51.jpg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO17-100x86.jpg 100w\" sizes=\"auto, (max-width: 744px) 100vw, 744px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Circuitry voltage input (0-10V)<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-1024x232.jpeg\" alt=\"\" class=\"wp-image-737\" width=\"512\" height=\"116\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-1024x232.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-400x91.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-150x34.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-768x174.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-50x11.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-1536x348.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-60x14.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential-100x23.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Differential.jpeg 1929w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-1024x227.jpeg\" alt=\"\" class=\"wp-image-739\" width=\"512\" height=\"114\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-1024x227.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-400x88.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-150x33.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-768x170.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-50x11.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-1536x340.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-60x13.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended-100x22.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Voltage-Input-Single-Ended.jpeg 1912w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Wiring current input (4-20mA)<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-1024x274.jpeg\" alt=\"\" class=\"wp-image-741\" width=\"512\" height=\"137\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-1024x274.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-400x107.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-150x40.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-768x205.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-50x13.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-1536x411.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-60x16.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output-100x27.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7017-Current-Output.jpeg 1605w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Function Expansion module for up to 8 external analog inputs. Communication is via Ethernet, so the module can be mounted anywhere. The configuration is done in the KentixONE software interface. The module offers easy IP configuration and testing of the inputs without additional software via the integrated web server. Connection&#8230;<\/p>\n","protected":false},"author":2,"featured_media":681,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[94,97],"ht-kb-tag":[],"class_list":["post-2107","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-data-sheets-en","ht_kb_category-data-sheets-en-4"],"custom_fields":{"kentix_order_code":["KIO7017"]},"categories":[{"slug":"data-sheets-en","name":"Datasheets","shortName":""},{"slug":"data-sheets-en-4","name":"Datasheets","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO70xx-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=2107"}],"version-history":[{"count":2,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2107\/revisions"}],"predecessor-version":[{"id":3222,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2107\/revisions\/3222"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/681"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=2107"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=2107"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=2107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}