{"id":2098,"date":"2023-01-08T20:55:57","date_gmt":"2023-01-08T19:55:57","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/outdoor-temperature-sensor-for-connection-to-kio7017-art-kesan1-data-sheet\/"},"modified":"2023-03-10T13:36:49","modified_gmt":"2023-03-10T12:36:49","slug":"outdoor-temperature-sensor-for-connection-to-kio7017-art-kesan1-data-sheet","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/outdoor-temperature-sensor-for-connection-to-kio7017-art-kesan1-data-sheet\/","title":{"rendered":"Outdoor temperature sensor for connection to KIO7017 &#8211; DATASHEET"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td>Active temperature sensor for harsh environments (outdoor areas, cold rooms, etc.)<\/td><\/tr><tr><td><strong>Connection<\/strong><\/td><td>I\/O module <a href=\"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-8-analog-inputs-art-kio7017-data-sheet\/\" data-type=\"ht_kb\" data-id=\"734\">KIO7017<\/a> with analog inputs<\/td><\/tr><tr><td><strong>Sensor<\/strong><\/td><td>PT100 Class B<\/td><\/tr><tr><td><strong>DIN<\/strong><\/td><td>DIN EN 60751<\/td><\/tr><tr><td><strong>Temp. Coefficient (sensor)<\/strong><\/td><td>3850 ppm\/K<\/td><\/tr><tr><td><strong>Measuring current<\/strong><\/td><td>1.0-3.0mA<\/td><\/tr><tr><td><strong>Error limit<\/strong><\/td><td>dT=+\/-(0.30\u00b0C+0.005xT)<\/td><\/tr><tr><td><strong>Circuit type<\/strong><\/td><td>3-wire<br>0-10V or 4-20mA configurable<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td>External 12-30VDC<\/td><\/tr><tr><td><strong>Operating temperature<\/strong><\/td><td>-50\u00b0C&#8230;+100\u00b0C<\/td><\/tr><tr><td><strong>Dimensions housing<\/strong><\/td><td>66 x 60 x 39(mm)<\/td><\/tr><tr><td><strong>Material housing<\/strong><\/td><td>Polyamide<\/td><\/tr><tr><td><strong>Connection terminals<\/strong><\/td><td>Screw terminal (max. 1.<sup>5mm2<\/sup>)<\/td><\/tr><tr><td><strong>Cable gland<\/strong><\/td><td>PG gland (4mm&#8230;10mm)<\/td><\/tr><tr><td><strong>Protection class<\/strong><\/td><td>IP65<\/td><\/tr><tr><td><strong>Scope of delivery<\/strong><\/td><td>KESAN1 Temperature sensor<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">The sensor requires an external power supply of 12-14VDC, a corresponding power supply unit is required.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Function Active temperature sensor for harsh environments (outdoor areas, cold rooms, etc.) Connection I\/O module KIO7017 with analog inputs Sensor PT100 Class B DIN DIN EN 60751 Temp. Coefficient (sensor) 3850 ppm\/K Measuring current 1.0-3.0mA Error limit dT=+\/-(0.30\u00b0C+0.005xT) Circuit type 3-wire0-10V or 4-20mA configurable Power supply External 12-30VDC Operating temperature&#8230;<\/p>\n","protected":false},"author":2,"featured_media":754,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[94,97],"ht-kb-tag":[],"class_list":["post-2098","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-data-sheets-en","ht_kb_category-data-sheets-en-4"],"custom_fields":{"kentix_order_code":["KESAN1, KESAN2"]},"categories":[{"slug":"data-sheets-en","name":"Datasheets","shortName":""},{"slug":"data-sheets-en-4","name":"Datasheets","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KESAN1-front-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2098","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=2098"}],"version-history":[{"count":2,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2098\/revisions"}],"predecessor-version":[{"id":3221,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2098\/revisions\/3221"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/754"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=2098"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=2098"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=2098"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}