{"id":2097,"date":"2023-01-08T15:33:47","date_gmt":"2023-01-08T14:33:47","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/multisensor-thermal-image-art-kms-ti-90-b-w-data-sheet\/"},"modified":"2025-08-12T09:27:35","modified_gmt":"2025-08-12T07:27:35","slug":"multisensor-thermal-image-art-kms-ti-90-b-w-data-sheet","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/multisensor-thermal-image-art-kms-ti-90-b-w-data-sheet\/","title":{"rendered":"MultiSensor-Thermal Image &#8211; Datasheet"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td>MultiSensor for early fire detection and room\/area monitoring<\/td><\/tr><tr><td><strong><strong><strong>Integrated software<\/strong><\/strong><\/strong><\/td><td>KentixONE via integrated web server (HTTPS)<\/td><\/tr><tr><td><strong>Sensor &#8211; air temperature<\/strong><\/td><td>Measuring range -40 to 85\u00b0C (accuracy \u00b1 0.5\u00b0C)<\/td><\/tr><tr><td><strong>Sensor &#8211; Relative humidity<\/strong><\/td><td>Measuring range 0 to 100% (accuracy \u00b13%)<\/td><\/tr><tr><td><strong>Sensor &#8211; dew point<\/strong><\/td><td>Calculated in \u00b0C<\/td><\/tr><tr><td><strong>Sensor &#8211; surface temperature<\/strong><\/td><td>1024 pixel infrared array with germanium glass optics, measuring range -40 to 1,000\u00b0C, detection cone depending on type: 40\u00b0 or 90\u00b0, range up to approx. 5m, measurement: temperature image (32&#215;32), movement<br\/>NETD (Noise Equivalent Temperature Difference): approx. 150mK\/1Hz<\/td><\/tr><tr><td><strong>Sensor &#8211; Vibration<\/strong><\/td><td>3-axis accelerometer with position detection (sensitivity adjustable), measuring range 0.25-5G<\/td><\/tr><tr><td><strong>Sensor &#8211; Carbon monoxide (CO)<\/strong><\/td><td>0-1,000ppm measurement \u00b1 10%, internal resolution: 20-1,000ppm (0-100%), service life 10 years<\/td><\/tr><tr><td><strong>Sensor &#8211; air quality (VOC, CO2)<\/strong><\/td><td>Measurement according to IAQ (Index for Air Quality), IAQ value 0-500 according to IAQ table*.<\/td><\/tr><tr><td><strong>Signal generator<\/strong><\/td><td>85dB, 2.3kHz<\/td><\/tr><tr><td><strong>External alarm inputs<\/strong><br\/>(KENTIX system socket)<\/td><td>2x alarm input (e.g. armed-active, continuous-active alarm), wiring with potential-free contacts via separate KIO3 IO adapter<\/td><\/tr><tr><td><strong>External signal outputs<\/strong><br\/>(KENTIX system socket)<\/td><td>2x signal output (e.g. armed-active alarm, continuous-active alarm), wiring via separate KIO3 IO adapter with relay outputs<\/td><\/tr><tr><td><strong>LED<\/strong><\/td><td>ALARM (red), RUN (green), LINK\/ACT to LAN socket<\/td><\/tr><tr><td><strong>Ethernet with PoE<\/strong><\/td><td>10\/100Mbit (default IP: 192.168.100.222)<br\/>Power supply via PoE Class 2, power consumption approx. 3W<\/td><\/tr><tr><td><strong>Radio (BLE 2.4GHz)<\/strong><br\/>(according to version)<\/td><td>2.4GHz ISM band (BLE), 128-bit encryption<\/td><\/tr><tr><td><strong>SD card<\/strong><\/td><td>Integrated Micro SD card holder as additional memory for image recording, up to 128 GB<\/td><\/tr><tr><td><strong>SNMP<\/strong><\/td><td>SNMP V2\/3 (write\/read), SNMP Traps (Simple Network Management Protocol)<\/td><\/tr><tr><td><strong>ReST API<\/strong><\/td><td>ReST API with JSON objects (HTTPS), webhooks<\/td><\/tr><tr><td><strong>Housing<\/strong><\/td><td>Material: PS 90 x 90 x 45 mm Weight approx. 100g<br\/>Colors: White, Black<\/td><\/tr><tr><td><strong>Environmental conditions<\/strong><\/td><td>Temperature 0 &#8211; 50\u00b0C, humidity 5-95%, non-condensing<\/td><\/tr><tr><td><strong>Versions<\/strong><\/td><td>KMS-TI-40-B-BLE (Black housing, 40\u00b0 optics)<br\/>KMS-TI-40-W-BLE (White housing, 40\u00b0 optics)<br\/>KMS-TI-90-B-BLE (Black housing, 90\u00b0 optics)<br\/>KMS-TI-90-W-BLE (White housing, 90\u00b0 optics)<br\/>KMS-TI-40-B (black housing, 40\u00b0 optics)<br\/>KMS-TI-40-W (white housing, 40\u00b0 optics)<br\/>KMS-TI-90-B (black housing, 90\u00b0 optics)<br\/>KMS-TI-90-W (white housing, 90\u00b0 optics)<\/td><\/tr><tr><td><strong>Scope of delivery<\/strong><\/td><td>Mounting bracket, mounting material, SlimLine cable 3m<\/td><\/tr><tr><td><strong>Accessories<\/strong><\/td><td>PoE injector (KPOE150S)<br\/>IO adapter (KIO3)<br\/>Leakage sensor (KLS03)<\/td><\/tr><tr><td><strong><strong><strong>Certification<\/strong><\/strong><\/strong><\/td><td>CE<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\"><strong>Thermal image sensor field of view<\/strong><\/h2>\n\n<h3 class=\"wp-block-heading\">40\u00b0 optics (ART: KMS-TI-40-x-x)<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Measuring distance<\/th><th class=\"has-text-align-center\" data-align=\"center\">Area<\/th><th class=\"has-text-align-center\" data-align=\"center\">Measuring grid<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1m<\/td><td class=\"has-text-align-center\" data-align=\"center\">73 x 73cm (0,53sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">2,27 x 2,27cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2m<\/td><td class=\"has-text-align-center\" data-align=\"center\">145 x 145cm (2,12sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">4,55 x 4,55cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3m<\/td><td class=\"has-text-align-center\" data-align=\"center\">218 x 218cm (4,55sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">6,82 x 6,82cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4m<\/td><td class=\"has-text-align-center\" data-align=\"center\">291 x 291cm (9,10sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">9,10 x 9,10cm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h3 class=\"wp-block-heading\">90\u00b0 optics (ART: KMS-TI-90-x-x)<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Measuring distance<\/th><th class=\"has-text-align-center\" data-align=\"center\">Area<\/th><th class=\"has-text-align-center\" data-align=\"center\">Measuring grid<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">1m<\/td><td class=\"has-text-align-center\" data-align=\"center\">200 x 200cm (4,00sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">6,25 x 6,25cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2m<\/td><td class=\"has-text-align-center\" data-align=\"center\">400 x 400cm (16,00sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">12,50 x 12,50cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3m<\/td><td class=\"has-text-align-center\" data-align=\"center\">600 x 600cm (36,00sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">18,75 x 18,75cm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">4m<\/td><td class=\"has-text-align-center\" data-align=\"center\">800 x 800cm (64,00sqm)<\/td><td class=\"has-text-align-center\" data-align=\"center\">25,00 x 25,00cm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\"><strong>Measurement of air quality according to IAQ Index*<\/strong><\/h2>\n\n<figure class=\"wp-block-table is-style-regular\"><table><tbody><tr><td><strong>Air index<\/strong><\/td><td><strong>Air quality<\/strong><\/td><td><strong>Effects (long-term exposure)<\/strong><\/td><td><strong>Proposed measure<\/strong><\/td><\/tr><tr><td><strong>0<\/strong> <strong>&#8211;<\/strong> <strong>50<\/strong><\/td><td>Excellent<\/td><td>Clean air; the best for the well-being<\/td><td>No measures required<\/td><\/tr><tr><td><strong>51<\/strong> <strong>&#8211;<\/strong> <strong>100<\/strong><\/td><td>Good<\/td><td>No irritation or effects on well-being<\/td><td>No measures required<\/td><\/tr><tr><td><strong>101<\/strong> <strong>&#8211;<\/strong> <strong>150<\/strong><\/td><td>Lightly soiled<\/td><td>Reduction of the well-being possible<\/td><td>Ventilation proposed<\/td><\/tr><tr><td><strong>151<\/strong> <strong>&#8211;<\/strong> <strong>200<\/strong><\/td><td>Moderately dirty<\/td><td>Clearer irritation possible<\/td><td>Increase ventilation with clean air<\/td><\/tr><tr><td><strong>201<\/strong> <strong>&#8211;<\/strong> <strong>250<\/strong><\/td><td>Heavily soiled<\/td><td>Depending on the type of VOCs, exposure can lead to effects such as headaches<\/td><td>Improve ventilation<\/td><\/tr><tr><td><strong>251<\/strong> <strong>&#8211;<\/strong> <strong>350<\/strong><\/td><td>Heavily soiled<\/td><td>More serious health problems possible if harmful VOCs are present<\/td><td>Contamination should be identified when level is reached even without people present; maximize ventilation &amp; reduce presence<\/td><\/tr><tr><td><strong>&gt;  351<\/strong><\/td><td>Extremely dirty<\/td><td>Headache, additional neurotoxic effects possible<\/td><td>Contaminants must be identified; avoid presence in the room and maximize ventilation<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Function MultiSensor for early fire detection and room\/area monitoring Integrated software KentixONE via integrated web server (HTTPS) Sensor &#8211; air temperature Measuring range -40 to 85\u00b0C (accuracy \u00b1 0.5\u00b0C) Sensor &#8211; Relative humidity Measuring range 0 to 100% (accuracy \u00b13%) Sensor &#8211; dew point Calculated in \u00b0C Sensor &#8211; surface&#8230;<\/p>\n","protected":false},"author":2,"featured_media":580,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[94,97],"ht-kb-tag":[],"class_list":["post-2097","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-data-sheets-en","ht_kb_category-data-sheets-en-4"],"custom_fields":{"kentix_order_code":["KMS-TI-90-B,KMS-TI-90-W,KMS-TI-90-B-BLE,KMS-TI-90-W-BLE,KMS-TI-40-B,KMS-TI-40-W,KMS-TI-40-B-BLE,KMS-TI-40-W-BLE"]},"categories":[{"slug":"data-sheets-en","name":"Datasheets","shortName":""},{"slug":"data-sheets-en-4","name":"Datasheets","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/343617_KMS-TI-B-front-1-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2097","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=2097"}],"version-history":[{"count":4,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2097\/revisions"}],"predecessor-version":[{"id":11787,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2097\/revisions\/11787"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/580"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=2097"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=2097"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=2097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}