{"id":2070,"date":"2023-01-08T19:56:08","date_gmt":"2023-01-08T18:56:08","guid":{"rendered":"https:\/\/docs2.kentix.com\/knowledge-base\/i-o-module-with-16-alarm-inputs-art-kio7053-data-sheet\/"},"modified":"2023-03-10T13:40:20","modified_gmt":"2023-03-10T12:40:20","slug":"i-o-module-with-16-alarm-inputs-art-kio7053-data-sheet","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/en\/knowledge-base\/i-o-module-with-16-alarm-inputs-art-kio7053-data-sheet\/","title":{"rendered":"I\/O module with 16 alarm inputs &#8211; DATASHEET"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td>Expansion module for up to 16 external alarm or system messages. Communication is via Ethernet, so the module can be mounted anywhere. The configuration is done in the KentixONE software interface. The module offers easy IP configuration and testing of the inputs without additional software via the integrated web server.<\/td><\/tr><tr><td>Connection possibility<\/td><td>AlarmManager or SiteManager<\/td><\/tr><tr><td><strong>Configuration<\/strong><\/td><td>Integr. Web server (HTTP)<br>Default IP: 192.168.255.1 (Admin\/Admin)<\/td><\/tr><tr><td><strong>Protocols<\/strong><\/td><td>Modbus communication via IP port: 502 (default)<\/td><\/tr><tr><td><strong>Security<\/strong><\/td><td>ID, password and IP filter<\/td><\/tr><tr><td><strong>Connection terminals<\/strong><\/td><td>Plug-in screw terminals for cables up to 1mm\u00b2<\/td><\/tr><tr><td><strong>Enter<\/strong><strong>\u00e4<\/strong><strong>nge<\/strong><\/td><td>Digital inputs for potential-free wiring<br>ON: Open<br>OFF: Input switched to GND<\/td><\/tr><tr><td><strong>Insulation<\/strong><\/td><td>Ethernet 1.5kVDC<br>InputsI\/O 3.7kVrms<\/td><\/tr><tr><td><strong>Environment<\/strong><\/td><td>Temperature 0\u00b0C to +45\u00b0C<br>Rel. Humidity 10-90%<\/td><\/tr><tr><td><strong>Network<\/strong><\/td><td>LAN 10\/100 Base-TX<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td>PoE (Class 2) or external power supply 12-30VDC, 4.5Watt<\/td><\/tr><tr><td>Housing<\/td><td>72 x 123 x 35 mm (DIN rail mounting)<\/td><\/tr><tr><td><strong>Scope of delivery<\/strong><\/td><td>KIO7053, 3m patch cable, power connection cable, manual<\/td><\/tr><tr><td><strong>Approval<\/strong><\/td><td>CE<\/td><\/tr><tr><td>Accessories<\/td><td>Power supply unit or PoE injector if no PoE supply is available.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Terminal assignment<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53.jpeg\" alt=\"\" class=\"wp-image-725\" width=\"744\" height=\"638\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53.jpeg 992w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53-400x343.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53-150x129.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53-768x658.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53-50x43.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53-60x51.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO53-100x86.jpeg 100w\" sizes=\"auto, (max-width: 744px) 100vw, 744px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Wiring (potential free)<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-1024x264.jpeg\" alt=\"\" class=\"wp-image-692\" width=\"512\" height=\"132\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-1024x264.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-400x103.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-150x39.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-768x198.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-50x13.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-1536x396.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-60x15.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1-100x26.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_ON-Stage-RB-as-1.jpeg 1656w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-1024x264.jpeg\" alt=\"\" class=\"wp-image-695\" width=\"512\" height=\"132\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-1024x264.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-400x103.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-150x39.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-768x198.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-50x13.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-1536x396.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-60x15.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0-100x26.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/7053_OFF-Stage-RB-as-0.jpeg 1648w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Function Expansion module for up to 16 external alarm or system messages. Communication is via Ethernet, so the module can be mounted anywhere. The configuration is done in the KentixONE software interface. The module offers easy IP configuration and testing of the inputs without additional software via the integrated web&#8230;<\/p>\n","protected":false},"author":2,"featured_media":681,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[94,97],"ht-kb-tag":[],"class_list":["post-2070","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-data-sheets-en","ht_kb_category-data-sheets-en-4"],"custom_fields":{"kentix_order_code":["KIO7053"]},"categories":[{"slug":"data-sheets-en","name":"Datasheets","shortName":""},{"slug":"data-sheets-en-4","name":"Datasheets","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KIO70xx-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/comments?post=2070"}],"version-history":[{"count":2,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2070\/revisions"}],"predecessor-version":[{"id":3224,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb\/2070\/revisions\/3224"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media\/681"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/media?parent=2070"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=2070"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=2070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}