{"id":935,"date":"2023-01-20T16:58:54","date_gmt":"2023-01-20T15:58:54","guid":{"rendered":"https:\/\/docs2.kentix.com\/?post_type=ht_kb&#038;p=935"},"modified":"2026-02-04T16:10:34","modified_gmt":"2026-02-04T15:10:34","slug":"smartpdu-40he-dual-2x16-32a-kpmdu-rc-xxxxc13c19-2-xx","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/de\/knowledge-base\/smartpdu-40he-dual-2x16-32a-kpmdu-rc-xxxxc13c19-2-xx\/","title":{"rendered":"Dual SmartPDU 40HE, 2&#215;16\/32A (bis 2x 7.3kVA)  &#8211; DATENBLATT"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Typen<\/th><th><strong>KPMDU-RC-xx-xx-4800-2-16-V<\/strong><\/th><th><strong>KPMDU-RC-xx-xx-4800-2-32-V<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Nennleistung, Spannung<\/strong><\/td><td>2x 3,6kVA, 230V<\/td><td>2x 7,3kVA, 230V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Anschlussstecker<\/strong><\/td><td>2x CEE-Stecker (<strong>BLAU<\/strong>) nach IEC60309, 1-polig, 16A\/230\/400V<\/td><td>2x CEE-Stecker (<strong>BLAU<\/strong>) nach IEC60309, 1-polig, 32A\/230\/400V<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Anschlusskabel<\/strong><\/td><td>2x L\u00e4nge 3m, GummischlauchleitungH07RN-F-5G6<\/td><td>2x L\u00e4nge 3m, GummischlauchleitungH07RN-F-5G6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Steckdosen C13 (IEC60320)<\/strong><\/td><td>48<\/td><td>48<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Steckdosen C19 (IEC60320)<\/strong><\/td><td>0<\/td><td>0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Verriegelung Steckdosen<\/strong><\/td><td colspan=\"2\">IEC-LOCK f\u00fcr C13\/C19<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Sicherung-Schutzschalter<\/strong><\/td><td>6 x 10A C-Typ, 6kA Kurzschlussstrom, verriegelt<\/td><td>6 x 16A C-Typ, 6kA Kurzschlussstrom, verriegelt<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Strommessung (geeicht)<\/strong><\/td><td colspan=\"2\">Integrierte, geeichte Strommessung, Genauigkeit Class B (MID, EN 50470-3)<br>Minimaler Strom\n          250mA, maximaler Strom 32A<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Differenzstrommessung (RCM)<\/strong><\/td><td colspan=\"2\">Integrierte AC\/DC sensitive Differenzstrommessung nach IEC 60664-1<br>\u00b1300mA\/100mA (RMS),\n          Genauigkeit &lt;0,2mA<br>Frequenzbereich DC 0..2kHz<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Konnektivit\u00e4t<\/strong><\/td><td colspan=\"2\">Ethernet (10\/100MBit), PoE Class 3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Kentix Systembuchse (Typ B)<\/strong><\/td><td colspan=\"2\">RJ45 mit Kentix spezifischer Belegung f\u00fcr Systemerweiterungen<br>2 x Digital Input (z.B.\n          T\u00fcrkontakte, Leckagemelder, ext. Alarme)<br>1 x System BUS<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Kommunikation und Sicherheit<\/strong><\/td><td colspan=\"2\">HTTPS (Zertifikat), integrierter Web-Server, ReSt-API<br>Protokolle: SNMP V2\/3 (GET, TRAP), NTP,\n          SMTP, DHCP, DNS, MODBUS-TCP<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Management<\/strong><\/td><td colspan=\"2\">Main-Satellite Verwaltung \u00fcber KentixONE<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Mess-\/Kommunikationsobjekte<\/strong><\/td><td colspan=\"2\">Spannung (V) L1\/L2\/L3\/Gesamt<br>Strom (A) L1\/L2\/L3\/Gesamt<br>Verbrauch (kWh)\n          L1\/L2\/L3\/Gesamt<br>Wirkleistung (W) L1\/L2L3\/Gesamt<br>Scheinleistung (VA) L1\/L2\/L3\/Gesamt<br>Blindleistung\n          (VAR) L1\/L2\/L3\/Gesamt<br>Wirkfaktor (cos phi)<br>Frequenz (Hz)<br>Phasen\u00fcberwachung L1\/L2\/L3<br>Differenzstrom\n          AC<br>Differenzstrom DC<br>Sicherungsstatus L1\/L2\/L3<br>Temperatur (\u00b0C)<br>Relative Luftfeuchte\n          (%)<br>Taupunkt (\u00b0C)<br>Vibration (G)<br>Luftqualit\u00e4t VOC (AIQ Index)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Display (LCD)<\/strong><\/td><td colspan=\"2\">Beleuchtetes LCD Display (Leistung, Strom, Spannung, Verbrauch)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Optische Signalisierung<\/strong><\/td><td colspan=\"2\">LED mit ROT\/GR\u00dcN (Betrieb, Alarm-\/Fehlerzustand)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Akustische Signalisierung<\/strong><\/td><td colspan=\"2\">Signalgeber mit 80dB, 2.3kHz (Alarm-\/Fehlerzust\u00e4nde)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Werkszustand<\/strong><\/td><td colspan=\"2\">Taster f\u00fcr Werks-Reset (<strong>Default-IP: 192.168.100.226<\/strong>)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Verlustleistung<\/strong><\/td><td colspan=\"2\">max. 40W (Volllast)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Geh\u00e4use<\/strong><\/td><td colspan=\"2\">Blech, Pulverbeschichtet RAL9005, Schutzklasse 1, Schutzart IP20, Montagehalter im Abstand 5HE\n          montierbar<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"1\"><strong>Gr\u00f6\u00dfe<\/strong><\/td><td colspan=\"2\">1770 x 78,2 x 62,5 mm (HxBxT)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Gewicht<\/strong><\/td><td colspan=\"2\">ca. 10,5kg<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Umgebungsbedingungen<\/strong><\/td><td colspan=\"2\">0\u00b0C bis 60\u00b0C, Luftfeuchte 5-95%, Lagertemperatur: -20\u00b0C bis 60\u00b0C<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong><strong>Zertifizierung<\/strong><\/strong><\/td><td colspan=\"2\">CE (2014\/30\/EG, 2014\/35\/EG, 2011\/65\/EU)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Elektrische Sicherheit<\/strong><\/td><td colspan=\"2\">DGUV-V3 Pr\u00fcfung, VDE 0105-100<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Kennzeichnung<\/strong><\/td><td colspan=\"2\">Seriennummer (Barcode), zus\u00e4tzlicher freier Kennzeichnungsbereich Frontplatte (60x30mm)<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Typen KPMDU-RC-xx-xx-4800-2-16-V KPMDU-RC-xx-xx-4800-2-32-V Nennleistung, Spannung 2x 3,6kVA, 230V 2x 7,3kVA, 230V Anschlussstecker 2x CEE-Stecker (BLAU) nach IEC60309, 1-polig, 16A\/230\/400V 2x CEE-Stecker (BLAU) nach IEC60309, 1-polig, 32A\/230\/400V Anschlusskabel 2x L\u00e4nge 3m, GummischlauchleitungH07RN-F-5G6 2x L\u00e4nge 3m, GummischlauchleitungH07RN-F-5G6 Steckdosen C13 (IEC60320) 48 48 Steckdosen C19 (IEC60320) 0 0 Verriegelung Steckdosen IEC-LOCK f\u00fcr C13\/C19&#8230;<\/p>\n","protected":false},"author":2,"featured_media":12626,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[73,64],"ht-kb-tag":[],"class_list":["post-935","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-datenblaetter","ht_kb_category-datenblaetter-smartpdu"],"custom_fields":{"kentix_order_code":["KPMDU-RC-xx-xx-4800-2-32-V, KPMDU-RC-xx-xx-4800-6-16-V"],"copied_media_ids":["a:0:{}"],"referenced_media_ids":["a:1:{i:0;i:12626;}"]},"categories":[{"slug":"datenblaetter","name":"Datenbl\u00e4tter Hardware","shortName":""},{"slug":"datenblaetter-smartpdu","name":"Datenbl\u00e4tter","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2025\/10\/kpmdu-scaled-4800-dual-150x7.webp","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/935","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/comments?post=935"}],"version-history":[{"count":22,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/935\/revisions"}],"predecessor-version":[{"id":12647,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/935\/revisions\/12647"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media\/12626"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media?parent=935"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-category?post=935"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-tag?post=935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}