{"id":567,"date":"2023-01-08T15:24:47","date_gmt":"2023-01-08T14:24:47","guid":{"rendered":"https:\/\/docs2.kentix.com\/?post_type=ht_kb&#038;p=567"},"modified":"2024-08-18T15:22:37","modified_gmt":"2024-08-18T13:22:37","slug":"wie-ist-die-belegung-des-kentix-sytemports","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/de\/knowledge-base\/wie-ist-die-belegung-des-kentix-sytemports\/","title":{"rendered":"Wie ist die Belegung der RJ45 Buchse der Kentix Sytemports (Typ A\/B)?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-1024x768.jpeg\" alt=\"\" class=\"wp-image-568\" style=\"width:512px;height:384px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-1024x768.jpeg 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-400x300.jpeg 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-150x113.jpeg 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-768x576.jpeg 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-50x38.jpeg 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-1536x1152.jpeg 1536w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-60x45.jpeg 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports-100x75.jpeg 100w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/KMS-LAN-ports.jpeg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcber den Kentix Systemport (Typ A) des MultiSensors k\u00f6nnen Systemkomponenten wie z.B. Leckagesensoren, T\u00fcrkontakte, Sirenen oder externe Alarme von USV oder Klimager\u00e4ten angeschlossen werden. Beim MultiSensor-RF erfolgt au\u00dferdem die Spannungsversorgung \u00fcber den Systemport (Typ A).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zur Aufschaltung externer Ger\u00e4te bzw. Alarme mit Ein- oder Ausg\u00e4ngen steht ein separat erh\u00e4ltliches Erweiterungsmodul (Systemport) mit dem ORDER_CODE: KIO3 zur Verf\u00fcgung.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Die Belegung des Systemports (Typ A) k\u00f6nnen Sie folgendem Schaltplan entnehmen.<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"705\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort.png\" alt=\"\" class=\"wp-image-542\" style=\"width:150px;height:176px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort.png 598w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-339x400.png 339w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-127x150.png 127w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-42x50.png 42w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-51x60.png 51w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/01\/SystemPort-85x100.png 85w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-1ea22f17-dd40-461b-a8b8-fc6b40201ad7\"><ol class=\"fa-ul\"><li>Interne Systemspannung (GND) &#8211; Nicht zur externen Nutzung<strong>*<\/strong><\/li><li>Ausgang 1 (Open Collector, max. 100mA)<\/li><li>Ausgang 2 (Open Collector, max 100mA)<\/li><li><strong>Externe Versorgungsspannung<\/strong>**<\/li><li><strong>Externe Versorgungsspannung<\/strong>**<\/li><li>Eingang 1 (Potentialfreie Beschaltung)<\/li><li>Eingang 2 (Potentialfreie Beschaltung)<\/li><li><strong>Interne Systemspannung (5VDC) &#8211; Nicht zur externen Nutzung*\/**<\/strong><\/li><\/ol><style>#heroic-styled-list-1ea22f17-dd40-461b-a8b8-fc6b40201ad7 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Die Belegung des Systemports (Typ B) unterscheidet sich wie folgt:<\/h3>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8dcf5574-8bf3-436a-aafb-83e8f364d54c\"><ol class=\"fa-ul\"><li>Interne Systemspannung (GND) &#8211; Nicht zur externen Nutzung<strong>*<\/strong><\/li><li>Ausgang 1 (Open Collector, max. 100mA)<\/li><li>Ausgang 2 (Open Collector, max 100mA)<\/li><li><strong>RS485 Schnittstelle (A)<\/strong>**<\/li><li><strong>RS485 Schnittstelle (B)<\/strong>**<\/li><li>Eingang 1 (Potentialfreie Beschaltung)<\/li><li>Eingang 2 (Potentialfreie Beschaltung)<\/li><li><strong>Interne Systemspannung (24VDC) &#8211; Nicht zur externen Nutzung*<\/strong>\/**<\/li><\/ol><style>#heroic-styled-list-8dcf5574-8bf3-436a-aafb-83e8f364d54c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>*&nbsp;Diese Anschl\u00fcsse sind nur zur internen Verwendung vorgesehen<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>** Unterschiedliche Belegung zwischen Systemport Typ A und Typ B<\/strong><\/p>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\">Die\u00a0Beschaltung sollte nur durch einen Fachmann mit elektrotechnischen Kenntnissen durchgef\u00fchrt werden. Eine Fehlbeschaltung kann zu Kurzschl\u00fcssen und Defekten f\u00fchren.<br>F\u00fcr die externe Beschaltung des Kentix Systemport (Typ A) empfehlen wir immer die Verwendung eines Erweiterungsmoduls (ORDER-CODE: KIO3). Das Erweiterungsmodul darf nicht in Verbindung mit dem Kentix Systemport (Typ B) verwendet werden.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u00dcber den Kentix Systemport (Typ A) des MultiSensors k\u00f6nnen Systemkomponenten wie z.B. Leckagesensoren, T\u00fcrkontakte, Sirenen oder externe Alarme von USV oder Klimager\u00e4ten angeschlossen werden. Beim MultiSensor-RF erfolgt au\u00dferdem die Spannungsversorgung \u00fcber den Systemport (Typ A). Zur Aufschaltung externer Ger\u00e4te bzw. Alarme mit Ein- oder Ausg\u00e4ngen steht ein separat erh\u00e4ltliches Erweiterungsmodul&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[62],"ht-kb-tag":[],"class_list":["post-567","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-faq-smartmonitoring"],"custom_fields":[],"categories":[{"slug":"faq-smartmonitoring","name":"FAQ","shortName":"FAQ"}],"featured_media_url":null,"_links":{"self":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/comments?post=567"}],"version-history":[{"count":19,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/567\/revisions"}],"predecessor-version":[{"id":10191,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/567\/revisions\/10191"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media?parent=567"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-category?post=567"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-tag?post=567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}