{"id":3319,"date":"2023-03-14T08:01:33","date_gmt":"2023-03-14T07:01:33","guid":{"rendered":"https:\/\/docs2.kentix.com\/?post_type=ht_kb&#038;p=3319"},"modified":"2025-12-08T14:09:15","modified_gmt":"2025-12-08T13:09:15","slug":"sitemanager-bedienungsanleitung","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/de\/knowledge-base\/sitemanager-bedienungsanleitung\/","title":{"rendered":"KentixONE mit SiteManager als Hardware-Appliance &#8211; BEDIENUNGSANLEITUNG"},"content":{"rendered":"\n<pre class=\"wp-block-verse\"><a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/sitemanager-datenblatt\/\" target=\"_blank\" rel=\"noreferrer noopener\">Datenblatt SiteManager<\/a><\/pre>\n\n\n\n<h2 class=\"wp-block-heading\">\u00dcbersicht<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der Kentix SiteManager ist die zentrale Verwaltungseinheit f\u00fcr alle Kentix Installationen. Der SiteManager arbeitet immer in der Betriebsart Main-Device und f\u00fchrt alle Funktionsbereiche wie SmartAccess, SmartMonitoring, SmartPDU und SmartVideo zusammen. Es k\u00f6nnen bis zu 500 Ger\u00e4te aus verschiedenen Funktionsbereichen gemanaged werden. Zudem beinhaltet er die Funktionalit\u00e4t einer Alarmzentrale mit verschiedenen \u00dcbertragungswegen (Netzwerk, Mobilfunk) zur Alarmierung. \u00dcber den integrierten Webserver (HTTPS) ist die Software KentixONE bereits integriert. Die Konfiguration erfolgt per Webbrowser. <br>Der SiteManager bietet mehrere Einbaum\u00f6glichkeiten wie Hutschienemontage auf 35mm DIN-Schiene oder Einbau im 19&#8243; IT-Rack mit einer H\u00f6heneinheit.<br>Die Spannungsversorgung erfolgt \u00fcber das integrierte Redundanzmodul mit zwei externen Netzteilen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sicherheitshinweise<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">Sicherheitshinweise<\/h2>\n\n\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation und Inbetriebnahme d\u00fcrfen nur durch geschultes Fachpersonal gem\u00e4\u00df Anleitung durchgef\u00fchrt werden.<br>An den Produkten der Kentix GmbH sind keine Modifikationen irgendeiner Art, mit Ausnahme der in einer entsprechenden Anleitung beschriebenen, zul\u00e4ssig.<br>Bei der Installation von Kentix Ger\u00e4ten m\u00fcssen bestimmte Schutzgrade gew\u00e4hrleistet werden.<br>Beachten Sie hierzu die einschl\u00e4gigen Vorschriften f\u00fcr Installationen in der jeweiligen Umgebung.<br>Die Produkte nur im definierten Temperaturbereich betreiben.<br>Die Anleitung sollte von der den Einbau vornehmenden Person an den Benutzer weitergegeben werden.<br>F\u00fcr Besch\u00e4digungen an den Ger\u00e4ten oder Bauteilen bei fehlerhafter Montage \u00fcbernimmt Kentix keine Haftung. Es wird keine Haftung bei fehlerhaft programmierten Einheiten \u00fcbernommen.<br>Treten St\u00f6rungen, Sachsch\u00e4den oder sonstige Sch\u00e4den auf, haftet Kentix nicht.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Gebrauch der Produkte, Transport und Lagerung<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Ger\u00e4t bei Transport, Lagerung und Betrieb vor<br>Feuchtigkeit, Schmutz und Besch\u00e4digung sch\u00fctzen.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Batteriebetriebene Produkte<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Produkte nicht in explosionsgef\u00e4hrdeten Bereichen einsetzen.<br>Die Produkte nur im definierten Temperaturbereich betreiben.<br>Der Einbau sowie der Batteriewechsel darf nur durch geschultes Fachpersonal gem\u00e4\u00df Anleitung durchgef\u00fchrt werden.<br>Batterien nicht aufladen, kurzschlie\u00dfen, \u00f6ffnen oder erhitzen.<br>Beim Einsetzen der Batterien auf die korrekte Polarit\u00e4t achten.<br>Die Ger\u00e4te m\u00fcssen immer mit den f\u00fcr das Produkt vorgesehenen Batterien betrieben werden.<br>Beim Wechseln der Batterien m\u00fcssen immer alle Batterien ausgetauscht werden.<br>Alte bzw. verbrauchte Batterien fachgerecht entsorgen.<br>Batterien au\u00dferhalb der Reichweite von Kindern aufbewahren. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Wartung<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix Ger\u00e4te sind im Rahmen einer j\u00e4hrlichen Wartung auf Funktionalit\u00e4t zu pr\u00fcfen.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Entsorgung<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Elektroger\u00e4te und Batterien sind getrennt vom Hausm\u00fcll zu entsorgen.<br><\/div><\/div><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Anschluss- und Bedienelemente<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports.png\" alt=\"\" class=\"wp-image-6475\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-fc969e33-a684-497d-95e2-fe638a9a481c\"><ol class=\"fa-ul\"><li>Anschluss 1 und Anschluss 2 zur Spannungsversorgung (24VDC) des Kentix SiteManagers<\/li><li>1GBit LAN-Anschluss 1  und 100MBit LAN-Anschluss 2<\/li><li>Systemport 1 (Typ A) und Systemport 2 (Typ A) zum Anschluss von Erweiterungssensoren<\/li><li>Nano-SIM-Karte (Einstecken mit den Kontakten nach unten) und Micro-SD-Karte (Einstecken mit den Kontakten nach oben). Beide Kartenhalter verf\u00fcgen \u00fcber eine Push-Push-Verriegelung.<\/li><\/ol><style>#heroic-styled-list-fc969e33-a684-497d-95e2-fe638a9a481c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2.png\" alt=\"\" class=\"wp-image-6477\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/KSM_ports_2-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-e9531e65-da3e-415a-9f70-9c131ae4030c\"><ol class=\"fa-ul\"><li>Status-LED 1 und Status-LED 2<\/li><li>Reset Taster zum Zur\u00fccksetzen auf Werkseinstellungen<\/li><li>SMA Buchse zum Anschluss der mitgelieferten LTE\/4G Magnetfu\u00df-Antenne<\/li><\/ol><style>#heroic-styled-list-e9531e65-da3e-415a-9f70-9c131ae4030c li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Ma\u00dfe<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600.png\" alt=\"\" class=\"wp-image-6202\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600.png 800w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-800-600-100x75.png 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Ma\u00dfe Draufsicht<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600.png\" alt=\"\" class=\"wp-image-6200\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600.png 800w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/07\/kentix-ksm-dr02-technical-drawing-2-800-600-100x75.png 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Ma\u00dfe Frontansicht<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Spannungsversorgung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Spannungsversorgung des SiteManagers erfolgt ausschlie\u00dflich \u00fcber externe Netzteile 24VDC \/ 0.5A. Das integrierte Redundanzmodul bietet die M\u00f6glichkeit, den SiteManager mit zwei externen Netzteilen zu versorgen. Die Netzteile werden \u00fcber einen Steckverbinder (WAGO Artikelnummer: 714-102) mit den Anschl\u00fcssen zur Spannungsversorgung am SiteManager verbunden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Einbaum\u00f6glichkeiten<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der SiteManager bietet verschiedene Montagem\u00f6glichkeiten wie Hutschienenmontage auf 35 mm DIN-Schiene oder Einbau in ein 19&#8243; IT-Rack mit einer H\u00f6heneinheit.<br>Die Montage auf Hutschienen TH 35-7.5 und TH 35-15 erfolgt \u00fcber die integrierte Schnellmontagehalterung auf der R\u00fcckseite des Geh\u00e4uses.<br>F\u00fcr den Einbau des SiteManagers in ein 19&#8243; IT-Rack werden die mitgelieferten Montagewinkel ben\u00f6tigt. Diese werden seitlich mit vier M3x5 Flachkopfschrauben an das Geh\u00e4use geschraubt. Hierzu wird ein Schraubendreher mit Innensechsrund TX10 ben\u00f6tigt. Zus\u00e4tzlich k\u00f6nnen die mitgelieferten Klettb\u00e4nder zur Kabelf\u00fchrung an den Montagewinkeln befestigt werden.<\/p>\n\n\n\n\n\n\n\n<h2 class=\"wp-block-heading\">Werkseinstellungen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Zur Erstkonfiguration verwenden Sie die auf dem Ger\u00e4t aufgedruckte IP-Adresse oder die per DHCP zugeteilte Adresse in einem Webbrowser (HTTPS). Beachten Sie hierbei die Netzwerkeinstellungen Ihres angeschlossenen PCs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die werkseitigen IP Adressen im \u00dcberblick:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-white-background-color has-background\"><tbody><tr><td><strong>SiteManager und AlarmManager<\/strong><\/td><td>192.168.100.222<\/td><\/tr><tr><td><strong>MultiSensor<\/strong><\/td><td>192.168.100.223<\/td><\/tr><tr><td><strong>AccessManager<\/strong><\/td><td>192.168.100.224<\/td><\/tr><tr><td><strong>PowerManager<\/strong><\/td><td>192.168.100.225<\/td><\/tr><tr><td><strong>SmartPDU<\/strong><\/td><td>192.168.100.226<\/td><\/tr><tr><td><strong>LeckageSensor<\/strong><\/td><td>192.168.100.227<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Werkseitige IP Adressen, Subnetz-Maske: 255.255.255.0<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">Bei Ger\u00e4ten mit einer Firmware-Version kleiner als 8.x.x sind die Anmelde-Daten f\u00fcr das voreingestellte Administrator-Konto: admin \/ password<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Auf Werkseinstellungen zur\u00fccksetzen<\/h2>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3\"><ol class=\"fa-ul\"><li>Das Ger\u00e4t neustarten (Spannungsversorgung trennen und erneut anschlie\u00dfen)<\/li><li>Die Status LED leuchtet kurz auf und erlischt.<\/li><li>Sobald die Status-LED dauerhaft gr\u00fcn leuchtet, den Reset Taster f\u00fcr 15 Sekunden gedr\u00fcckt halten bis das Ger\u00e4t eine akustische R\u00fcckmeldung gibt.<\/li><li>Das Ger\u00e4t l\u00e4dt die Werkseinstellungen und f\u00fchrt einen Neustart durch.<\/li><li>Nach ca. 2 Minuten ist das Ger\u00e4t mit den Werkseinstellungen erreichbar.<\/li><\/ol><style>#heroic-styled-list-8ab5ec5e-8bd5-415b-9057-88ba9b95d4f3 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-danger\"><strong>Alle vorhanden Einstellungen und Daten werden unwiderruflich gel\u00f6scht !<\/strong><br><strong>Wir empfehlen regelm\u00e4\u00dfige Sicherung des Systems<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Konfiguration mit KentixONE<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Konfiguration des Ger\u00e4ts erfolgt \u00fcber den Webbrowser in KentixONE. Das Ger\u00e4t muss netzwerkseitig f\u00fcr die zentrale KentixONE-Instanz erreichbar sein. Je nach Ger\u00e4tetyp m\u00fcssen au\u00dferdem ein Kommunikationsschl\u00fcssel sowie die IP-Adresse bzw. der DHCP-Name der zentralen KentixONE-Instanz auf dem Ger\u00e4t gesetzt werden (MultiSensoren, AccessManager, SmartPDU). IP-Kameras oder IO-Module k\u00f6nnen dagegen direkt in KentixONE eingebunden werden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alle Information zur Software erhalten Sie im Bereich <a href=\"https:\/\/docs.kentix.com\/kentixone\/\" target=\"_blank\" rel=\"noreferrer noopener\">KentixONE<\/a> und der zugeh\u00f6rigen Dokumentation.<\/p>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\">Achten Sie vor Beginn der Konfiguration darauf, dass die Software auf allen netzwerkf\u00e4higen Kentix-Ger\u00e4ten aktuell ist. Der Versionsstand muss auf allen Ger\u00e4ten \u00fcbereinstimmen.<br><strong>Ein Software-Update k\u00f6nnen Sie jederzeit \u00fcber \u201eSystem \u2013 Update\u201d f\u00fcr Ihre KentixONE Hauptinstanz und alle angeschlossenen Satelliten durchf\u00fchren.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Datenblatt SiteManager \u00dcbersicht Der Kentix SiteManager ist die zentrale Verwaltungseinheit f\u00fcr alle Kentix Installationen. Der SiteManager arbeitet immer in der Betriebsart Main-Device und f\u00fchrt alle Funktionsbereiche wie SmartAccess, SmartMonitoring, SmartPDU und SmartVideo zusammen. Es k\u00f6nnen bis zu 500 Ger\u00e4te aus verschiedenen Funktionsbereichen gemanaged werden. Zudem beinhaltet er die Funktionalit\u00e4t einer&#8230;<\/p>\n","protected":false},"author":6,"featured_media":6551,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[228],"ht-kb-tag":[],"class_list":["post-3319","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-kentixone-plattform"],"custom_fields":{"kentix_order_code":["KSM-DR-02"],"kentix_skill_level":["2"]},"categories":[{"slug":"kentixone-plattform","name":"KentixONE Plattform","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/08\/kentix-ksm-dr-1-perspektive-hochkant-web-2_1920x1920-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/3319","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/comments?post=3319"}],"version-history":[{"count":56,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/3319\/revisions"}],"predecessor-version":[{"id":12352,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/3319\/revisions\/12352"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media\/6551"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media?parent=3319"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-category?post=3319"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-tag?post=3319"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}