{"id":2468,"date":"2023-02-27T17:16:45","date_gmt":"2023-02-27T16:16:45","guid":{"rendered":"https:\/\/docs2.kentix.com\/?post_type=ht_kb&#038;p=2468"},"modified":"2024-07-30T11:32:41","modified_gmt":"2024-07-30T09:32:41","slug":"fingerprint-leser-doorlock-wa5-ip-bedienungsanleitung","status":"publish","type":"ht_kb","link":"https:\/\/docs.kentix.com\/de\/knowledge-base\/fingerprint-leser-doorlock-wa5-ip-bedienungsanleitung\/","title":{"rendered":"Fingerprint Leser DoorLock-WA5 - BEDIENUNGSANLEITUNG"},"content":{"rendered":"\n<pre class=\"wp-block-preformatted\"><a href=\"https:\/\/docs.kentix.com\/de\/knowledge-base\/doorlock-kxc-wa5-art-kxc-wa5-ip2\/\" target=\"_blank\" rel=\"noreferrer noopener\">DATENBLATT KXC-WA5-IP2<\/a><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Der Fingerprintleser erm\u00f6glicht das Entriegeln von T\u00fcren mittels Fingerabdruck und RFID-Karte\/Token. Dabei handelt es sich um eine Zwei-Faktor-Authentifizierung (2FA), bei der immer beide Komponenten zum \u00d6ffnen einer T\u00fcr ben\u00f6tigt werden. Es ist nicht m\u00f6glich, nur einen Finger oder nur die RFID-Karte zu verwenden. Der Wandleser wird \u00fcber ein SmartRelay angeschlossen und kann dann \u00fcber den Main\/Satellite-Modus mit einem AccessManager (KXP-2-RS) verbunden werden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sicherheitshinweise<\/h2>\n\n\n\n<div class=\"wp-block-ht-blocks-accordion wp-block-hb-accordion\"><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Installation<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Installation und Inbetriebnahme d\u00fcrfen nur durch geschultes Fachpersonal gem\u00e4\u00df Anleitung durchgef\u00fchrt werden.<br>An den Produkten der Kentix GmbH sind keine Modifikationen irgendeiner Art, mit Ausnahme der in einer entsprechenden Anleitung beschriebenen, zul\u00e4ssig.<br>Bei der Installation von Kentix Ger\u00e4ten m\u00fcssen bestimmte Schutzgrade gew\u00e4hrleistet werden.<br>Beachten Sie hierzu die einschl\u00e4gigen Vorschriften f\u00fcr Installationen in der jeweiligen Umgebung.<br>Die Produkte nur im definierten Temperaturbereich betreiben.<br>Die Anleitung sollte von der den Einbau vornehmenden Person an den Benutzer weitergegeben werden.<br>F\u00fcr Besch\u00e4digungen an den Ger\u00e4ten oder Bauteilen bei fehlerhafter Montage \u00fcbernimmt Kentix keine Haftung. Es wird keine Haftung bei fehlerhaft programmierten Einheiten \u00fcbernommen.<br>Treten St\u00f6rungen, Sachsch\u00e4den oder sonstige Sch\u00e4den auf, haftet Kentix nicht.<br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Gebrauch der Produkte, Transport und Lagerung<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Ger\u00e4t bei Transport, Lagerung und Betrieb vor<br>Feuchtigkeit, Schmutz und Besch\u00e4digung sch\u00fctzen.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Batteriebetriebene Produkte<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Produkte nicht in explosionsgef\u00e4hrdeten Bereichen einsetzen.<br>Die Produkte nur im definierten Temperaturbereich betreiben.<br>Der Einbau sowie der Batteriewechsel darf nur durch geschultes Fachpersonal gem\u00e4\u00df Anleitung durchgef\u00fchrt werden.<br>Batterien nicht aufladen, kurzschlie\u00dfen, \u00f6ffnen oder erhitzen.<br>Beim Einsetzen der Batterien auf die korrekte Polarit\u00e4t achten.<br>Die Ger\u00e4te m\u00fcssen immer mit den f\u00fcr das Produkt vorgesehenen Batterien betrieben werden.<br>Beim Wechseln der Batterien m\u00fcssen immer alle Batterien ausgetauscht werden.<br>Alte bzw. verbrauchte Batterien fachgerecht entsorgen.<br>Batterien au\u00dferhalb der Reichweite von Kindern aufbewahren. <br><\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Wartung<br><\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Kentix Ger\u00e4te sind im Rahmen einer j\u00e4hrlichen Wartung auf Funktionalit\u00e4t zu pr\u00fcfen.<\/div><\/div><\/div><div class=\"wp-block-hb-accordion__section\" data-ht-blocks-accordion-block-state=\"closed\"><div class=\"wp-block-hb-accordion__title\"><span>Entsorgung<\/span><\/div><div class=\"wp-block-hb-accordion__content\"><div class=\"wp-block-hb-accordion__contentwrap\">Elektroger\u00e4te und Batterien sind getrennt vom Hausm\u00fcll zu entsorgen.<br><\/div><\/div><\/div><\/div>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">F\u00fcr den Betrieb von Wandlesern ist ein Kentix AccessManager f\u00fcr Kabel Leser (KXP-2-RS) notwendig. Informationen zum Relais und<strong> Schaltpl\u00e4ne inklusive Beispiele<\/strong> finden Sie hier:&nbsp;<a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">Kentix SmartRelay (KXP-2-RS)<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Bedienelemente<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">DoorLock-WA5-IP Vorderseite<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139.png\" alt=\"\" class=\"wp-image-2473\" style=\"width:668px;height:501px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-139-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">DoorLock-WA5-IP Ansicht Vorderseite<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-38f02c7f-686f-4d79-87c2-ac0f1fcf1b68\"><ol class=\"fa-ul\"><li>Fingerprint Sensor zum erstellen der Templates im Einlernvorgang und zum \u00d6ffnen der T\u00fcr mithilfe der RFID-Karte und Fingerabdruck<\/li><li>Status LED zur Signalisierung der verschiedenen Modi und Zust\u00e4nde des Lesers<\/li><li>Integrierter RFID Reader, die gesamte Oberfl\u00e4che dient als Lesefl\u00e4che<\/li><\/ol><style>#heroic-styled-list-38f02c7f-686f-4d79-87c2-ac0f1fcf1b68 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">DoorLock-WA5-IP R\u00fcckseite<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141.png\" alt=\"\" class=\"wp-image-2477\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-141-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">DoorLock-WA5-IP Ansicht R\u00fcckseite<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-8340415e-690b-479d-af88-af79f0faec4a\"><ol class=\"fa-ul\"><li>Anschlussklemmen, f\u00fcr die Belegung siehe Tabelle<\/li><li>DIP-Schalter 1, f\u00fcr die Konfiguration siehe Tabelle<\/li><li>DIP-Schalter 2, f\u00fcr die Konfiguration siehe Tabelle<\/li><\/ol><style>#heroic-styled-list-8340415e-690b-479d-af88-af79f0faec4a li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Klemmenbelegung<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Klemme<\/th><th>Funktion<\/th><\/tr><tr><td>1<\/td><td>10-30V\/DC, max. 3,5VA<\/td><\/tr><tr><td>2<\/td><td>GND<\/td><\/tr><tr><td>3<\/td><td>RS485 Data &#8222;A&#8220;<\/td><\/tr><tr><td>4<\/td><td>RS485 Data &#8222;B&#8220;<\/td><\/tr><tr><td>5<\/td><td>Bezugspotential<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA5-IP Klemmenbelegung<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">DIP-Schalter 1<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>DIP-Schalter 1<\/th><th>Funktion<\/th><\/tr><tr><td>1<\/td><td>Abschlusswiderstand* (120 Ohm)<\/td><\/tr><tr><td>2<\/td><td>-<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA5-IP DIP-Schalter 1<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-alert\">*Der Abschlusswiderstand wird ab einer Kabell\u00e4nge von mehr als 500m notwendig.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">DIP-Schalter 2<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>DIP-Schalter 2<\/th><th>Funktion<\/th><\/tr><tr><td>1<\/td><td>Adresse 1 (1=ON, 2=OFF)<\/td><\/tr><tr><td>2<\/td><td>Adresse 2 (1=OFF, 2=ON)<\/td><\/tr><tr><td>3<\/td><td>-<\/td><\/tr><tr><td>4<\/td><td>-<\/td><\/tr><tr><td>5<\/td><td>-<\/td><\/tr><tr><td>6<\/td><td>6=ON (f\u00fcr Baudrate 19200)<\/td><\/tr><tr><td>7<\/td><td>7=OFF&nbsp;(f\u00fcr Baudrate 19200)<\/td><\/tr><tr><td>8<\/td><td>&nbsp;-<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">WA5-IP DIP-Schalter 2<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Einlernvorgang (Enrolment)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Starten des Enrolmentvorgangs<\/h3>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-0e622be3-bdc2-48a7-bd12-8a5d1d13ba52\"><ol class=\"fa-ul\"><li>Sie starten den Enrolmentvorgang direkt in den Einstellungen des Benutzers in KentixOne<\/li><li>Dr\u00fccken Sie hierzu das +-Symbol neben dem RFID-Feld und w\u00e4hlen anschlie\u00dfend den Fingerprintleser aus, an dem der Enrolmentvorgang durchgef\u00fchrt wird<\/li><li>Die Fingerabdruck Lesefl\u00e4che signalisiert durch rotes Leuchten den Start des Enrolmentvorgangs<\/li><\/ol><style>#heroic-styled-list-0e622be3-bdc2-48a7-bd12-8a5d1d13ba52 li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Einlernen der Finger (Enrolmentvorgang)<\/h3>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-85ecd849-8b11-4e3a-8219-40d4e6f8a4ea\"><ol class=\"fa-ul\"><li>Legen Sie den gew\u00fcnschten Finger auf die Fingerabdruck Lesefl\u00e4che. Der erfolgreiche Einlesevorgang wird mit einem Signalton best\u00e4tigt<\/li><li>Legen Sie den Finger erneut auf die Fingerabdruck Lesefl\u00e4che auf bis zum Signalton<\/li><li>Legen Sie den Finger ein drittes mal auf die Fingerabdruck Lesefl\u00e4che auf bis zum Signalton<\/li><li>Wiederholen Sie diesen Vorgang (1-3) mit einem zweiten Finger<\/li><li>Nach dem dritten Lesevorgang des zweiten Fingers muss die RFID Karte vor die RFID Lesefl\u00e4che gehalten werden<\/li><\/ol><style>#heroic-styled-list-85ecd849-8b11-4e3a-8219-40d4e6f8a4ea li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Speichervorgang auf RFID-Karte und Abschluss des Enrolmentvorgangs<\/h3>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-d4a0fcaa-af26-444f-954a-472700ed396b\"><ol class=\"fa-ul\"><li>Halten Sie die RFID Karte erneut vor die RFID Lesefl\u00e4che.<\/li><li>Nun legen Sie nochmal abschlie\u00dfend den Finger auf die Lesefl\u00e4che<\/li><li>Der erfolgreiche Schreibvorgang wird mit gr\u00fcn leuchtender Status LED <i class=\"fas fa-circle\"><\/i> und einem Signalton best\u00e4tigt<\/li><\/ol><style>#heroic-styled-list-d4a0fcaa-af26-444f-954a-472700ed396b li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u00d6ffnungsvorgang<\/h2>\n\n\n\n<div class=\"wp-block-ht-blocks-list heroic-styled-list\" id=\"heroic-styled-list-3015b627-20b9-46dc-88cb-186efb1e7aff\"><ol class=\"fa-ul\"><li>Halten Sie die RFID-Karte vor die RFID Lesefl\u00e4che<\/li><li>Der Fingerabdruck Leser wird aktiviert und die Lesefl\u00e4che leuchtet<\/li><li>Legen Sie den eingelernten Finger auf den Leser. Der erfolgreiche Vorgang wird durch ein gr\u00fcnes leuchten der Status LED und ein Signalton best\u00e4tigt<\/li><\/ol><style>#heroic-styled-list-3015b627-20b9-46dc-88cb-186efb1e7aff li:before{\n\t\t                   background:#f7931e;\n\t\t                   border-radius: 0;\n\t\t                   }<\/style><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Detaillierte Beschaltung und Klemmenplan f\u00fcr zwei T\u00fcren mit zwei Fingerprint Lesern<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der nachfolgende Anschlussplan zeigt die generelle Beschaltung des <a href=\"https:\/\/shop.kentix.com\/de-de\/search?search=smartrelay\" target=\"_blank\" rel=\"noreferrer noopener\">SmartRelay<\/a> Moduls mit zwei Wandlesern und zwei T\u00fcrkontakten zur \u00dcberwachung des T\u00fcrstatus. Die Anbindung der Leser erfolgt \u00fcber einen BUS (RS485) mit einer Gesamtkabell\u00e4nge bis ca. 600m Kabell\u00e4nge. Als Verbindungskabel empfehlen wir I(ST)Y-2x2x0.8 zwischen SmartRelay und Leser. Die Spannungsversorgung des SmartRelay Moduls erfolgt \u00fcber Ethernet PoE, dabei liefert das Modul als PoE Splitter zwei 24VDC Spannungsausg\u00e4nge zur Versorgung der Leser und der Schlosssteuerung. Bei der Spannungsversorgung der Schl\u00f6sser (T\u00fcr\u00f6ffner, Motorschloss, Magnethalter) ist zu beachten, dass der Splitter maximal 10W an Leistung liefern kann. Wird mehr Leistung zur Ansteuerung ben\u00f6tigt muss die Spannungsversorgung der Schl\u00f6sser \u00fcber ein externe Netzteil erfolgen. Der Vorteil bei Nutzung des Splitters und PoE ist die Gleichzeitige Notspannungsversorgung der T\u00fcrsteuerung bei Verwendung einer USV am PoE versorgenden Switch.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142.png\" alt=\"\" class=\"wp-image-2480\" style=\"width:668px;height:501px\" srcset=\"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142.png 1024w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142-400x300.png 400w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142-150x113.png 150w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142-768x576.png 768w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142-50x38.png 50w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142-60x45.png 60w, https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-142-100x75.png 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Die beiden Leser werden grunds\u00e4tzlich aus dem SmartRelay Modul mit Spannung versorgt. Spannungsversorgung und Kommunikationsbus (A+B) werden in einer Leitung gef\u00fchrt.<\/li>\n\n\n\n<li>Die beiden Relais (Rel1+2) k\u00f6nnen \u00fcber Jumper auf die ben\u00f6tigte Logik NC\/NO (Normally Closed\/Normally Opened) eingestellt werden.<\/li>\n\n\n\n<li>Die beiden T\u00fcrkontakte an Eingang 1+2 (DI1+2) ben\u00f6tigen einen potentialfreien Kontakt (z.B. Reed-Kontakt) zur Anschaltung an DI1+2.<\/li>\n\n\n\n<li>*Die Spannungsversorgung durch den PoE Splitter kann durch eine externe Spannungsversorgung ersetzt werden. Diese dann notwendig wenn der Splitter nicht die passende Spannung (24VDC) oder nicht die ben\u00f6tigte Leistung liefert (&gt;10W).<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>DATENBLATT KXC-WA5-IP2 Der Fingerprintleser erm\u00f6glicht das Entriegeln von T\u00fcren mittels Fingerabdruck und RFID-Karte\/Token. Dabei handelt es sich um eine Zwei-Faktor-Authentifizierung (2FA), bei der immer beide Komponenten zum \u00d6ffnen einer T\u00fcr ben\u00f6tigt werden. Es ist nicht m\u00f6glich, nur einen Finger oder nur die RFID-Karte zu verwenden. Der Wandleser wird \u00fcber ein&#8230;<\/p>\n","protected":false},"author":4,"featured_media":2469,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"_crdt_document":"","inline_featured_image":false,"footnotes":""},"ht-kb-category":[102],"ht-kb-tag":[],"class_list":["post-2468","ht_kb","type-ht_kb","status-publish","format-standard","has-post-thumbnail","hentry","ht_kb_category-smartaccess-produktarchiv"],"custom_fields":{"kentix_order_code":["KXC-WA5-IP2"],"kentix_legacy_product":["1"]},"categories":[{"slug":"smartaccess-produktarchiv","name":"SmartAccess Produktarchiv","shortName":""}],"featured_media_url":"https:\/\/docs.kentix.com\/wp-content\/uploads\/2023\/02\/grafik-138-150x113.png","_links":{"self":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/2468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/comments?post=2468"}],"version-history":[{"count":14,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/2468\/revisions"}],"predecessor-version":[{"id":10124,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb\/2468\/revisions\/10124"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media\/2469"}],"wp:attachment":[{"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/media?parent=2468"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-category?post=2468"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/docs.kentix.com\/de\/wp-json\/wp\/v2\/ht-kb-tag?post=2468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}